Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We have constructed a low-cost, portable, high-sensitivity 16-channel optically pumped magnetometer (OPM), operating in the spin-exchange relaxation-free regime, and demonstrated its applications in magnetocardiography (MCG). The decrease in the cost of sensors by an order of magnitude is achieved by the 16-channel operation realized in a single module using a single large flat pancake rubidium vapor cell, broad pump and probe laser beams, and a 16-channel photodiode array. The OPM is also based on a fiber-coupled nearly parallel-beam configuration to facilitate multichannel design and make the system portable. For human MCG experiments, the 16-channel OPM which includes optical components is placed inside a wooden enclosure for laser safety. The enclosure is set on a nonmagnetic table inside a magnetically shielded room, while the lasers and electronics are placed outside the shielding room, to avoid magnetic noise. We show that the 16-channel OPM enables simultaneous imaging of human cardiac activity on a large area of the chest in a single scan. The multichannel capability will accelerate clinical MCG imaging to reduce the procedure time and patient fatigue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The MCG measurements usually require the participant keeping still in a magnetically shielded room due to the immovable sensor and noisy external environments.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [36]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Previously, biomagnetic signal measurements based on OPMs are often performed in magnetically shielded environments (35, 36) due to the magnetic field noise from surroundings. Despite there being several works on unshielded biomagnetic signal measurements (35, 37), these shielded or unshielded measurements normally require the participant to remain still during the measurement.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [36]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
Seltzer, S. J., & Romalis, M. V. (2004) · Applied Physics Letters · doi:10.1063/1.1814434 · Cited by 320
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
A laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185
Multi-channel atomic magnetometer for magnetoencephalography: A configuration study
Kim, K., Begus, S., Xia, H., Lee, S.-K., Jazbinsek, V., Trontelj, Z., & Romalis, M. V. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.040 · Cited by 170
Multichannel biomagnetic system for study of electrical activity in the brain and heart
Schneider, S., Hoenig, E., Reichenberger, H., Abraham-Fuchs, K., Moshage, W., Oppelt, A., Stefan, H., Weikl, A., & Wirth, A. (1990) · Radiology · doi:10.1148/radiology.176.3.2389043 · Cited by 74
Kim, Y. J., Chu, P.-H., & Savukov, I. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.091802 · Cited by 67
Self-citation
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“Previously, biomagnetic signal measurements based on OPMs are often performed in magnetically shielded environments ( 35 , 36 ) due to the magnetic field noise from surroundings.”
Parameter Modeling Analysis of a Cylindrical Ferrite Magnetic Shield to Reduce Magnetic Noise
Ma, D., Lu, J., Fang, X., Yang, K., Wang, K., Zhang, N., Han, B., & Ding, M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3050351 · Cited by 99
Tang, J., Zhai, Y., Zhou, B., Han, B., & Liu, G. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3112797 · Cited by 102
Three-axis closed-loop optically pumped magnetometer operated in the SERF regime
Yan, Y., Lu, J., Zhang, S., Lu, F., Yin, K., Wang, K., Zhou, B., & Liu, G. (2022) · Optics Express · doi:10.1364/oe.458367 · Cited by 89
Tang, J., Liu, Y., Wang, Y., Zhou, B., Han, B., Zhai, Y., & Liu, G. (2022) · Applied Physics Letters · doi:10.1063/5.0080764 · Cited by 87
All-optical dual-axis zero-field atomic magnetometer using light-shift modulation
Li, X., Han, B., Zhang, K., Liu, Z., Wang, S., Yan, Y., & Lu, J. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.014023 · Cited by 75
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Fourcault, W., Romain, R., Le Gal, G., Bertrand, F., Josselin, V., Le Prado, M., Labyt, E., & Palacios-Laloy, A. (2021) · Optics Express · doi:10.1364/oe.420031 · Cited by 65
Fang, X., Wei, K., Zhai, Y., Zhao, T., Chen, X., Zhou, M., Liu, Y., Ma, D., & Xiao, Z. (2022) · Optics Express · doi:10.1364/oe.447041 · Cited by 64
Magnetic Measurement of Electrically Evoked Muscle Responses With Optically Pumped Magnetometers
Elzenheimer, E., Laufs, H., Schulte‐Mattler, W., & Schmidt, G. U. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2968148 · Cited by 58
“Nevertheless, there are some biomedical applications (e.g., magnetoencephalography (MEG) [25] and magnetocardiography (MCG) [26]) for which OPMs are quite well suited at the current state of research.”
BackgroundZhao, F., Zhou, X., Xie, X., & Wang, K. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3106677 · Cited by 54
Fang, X., Wei, K., Zhao, T., Zhai, Y., Ma, D., Xing, B., Liu, Y., & Xiao, Z. (2020) · Optics Express · doi:10.1364/oe.398540 · Cited by 49
Optimized gas pressure of an Rb vapor cell in a single-beam SERF magnetometer
Wang, Y., Jin, G., Tang, J., Zhou, W., Han, B., Zhou, B., & Shi, T. (2021) · Optics Express · doi:10.1364/oe.447456 · Cited by 47
Single beam Cs-Ne SERF atomic magnetometer with the laser power differential method
Chen, Y., Zhao, L., Zhang, N., Yu, M., Ma, Y., Han, X., Zhao, M., Lin, Q., Yang, P., & Jiang, Z. (2022) · Optics Express · doi:10.1364/oe.450571 · Cited by 42
Analysis and suppression of magnetic noise of cylindrical nanocrystalline shield in atomic sensors
Ye, L., Pang, H., Ma, L., Quan, J., Fan, W., Wu, Z., & Quan, W. (2023) · Measurement · doi:10.1016/j.measurement.2023.113656 · Cited by 36
Guo, Q., Hu, T., Chen, C.-Q., Feng, X., Wu, Z., Zhang, Y., Zhang, M., Chang, Y., & Yang, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3102146 · Cited by 38
A kilohertz bandwidth and sensitive scalar atomic magnetometer using an optical multipass cell
Li, S., Liu, J., Jin, M., Tetteh, A. K., Dai, P., Xu, Z., & Nwodom, T. E.-T. (2022) · Measurement · doi:10.1016/j.measurement.2022.110704 · Cited by 37
Parameter optimisation of miniaturised SERF magnetometer below relaxation rate saturation region
Li, R., Liu, Y., Li, C., Li, S., Li, J., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.112733 · Cited by 36
Liu, Y., Yang, J., Cao, F., Zhang, X., & Zheng, S. (2024) · Materials · doi:10.3390/ma17225469 · Cited by 37
“With its advantages of high sensitivity and miniaturization, SERF atomic magnetometers play a key role in the field of extremely weak biological magnetic field measurement represented by magnetocardiography (MCG) [12,13] and magnetoencephalogram (MEG) [14,15].”
Zhang, J., Liu, K., Zhang, J., Wang, Z., & Shang, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3120375 · Cited by 33
Integrated Polarization-Splitting Grating Coupler for Chip-Scale Atomic Magnetometer
Hu, J., Lu, J., Liang, Z., Liu, L., Wang, W., Zhou, P., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12070529 · Cited by 29
“Moreover, this device is especially advantageous for future on-chip multi-channel AMs, which is in urgent demand for multi-channel high-spatial-resolution MEG and MCG.”
BackgroundVector Magnetic Field Imaging With High-Resolution TMR Sensor Arrays for Metal Structure Inspection
Sun, K., Qi, P., Tao, X., Zhao, W., & Ye, C. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3181366 · Cited by 26
Yang, J., Zhang, X., Shi, M., Yuan, S., Wang, L., & Han, B. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3314921 · Cited by 25
“For example, in research on magnetocardiograms [6], [7] and mag-netoencephalograms (MEG) [8], [9], it is important to directly measure the magnetic fields generated by the action potential in the heart and neural currents in the brain.”
BackgroundTransient dynamics of atomic spin in the spin-exchange-relaxation-free regime
Tang, J., Yin, Y., Zhai, Y., Zhou, B., Han, B., Yang, H., & Liu, G. (2021) · Optics Express · doi:10.1364/oe.418776 · Cited by 27
Design of Highly Uniform Radial Coils Considering the Coupling Effect of Magnetic Shielding Cylinder
Wang, W., Zhou, X., Zhao, F., Xie, X., & Zhou, W. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3341108 · Cited by 23
“Especially in recent years, spin-exchange relaxation-free (SERF) atomic sensors have achieved breakthroughs in noninvasive brain and heart detection and are critical for magnetoencephalography (MEG) and magnetocardiography (MCG) [8], [9].”
BackgroundTriaxial Vector Operation in Near-Zero Field of Atomic Magnetometer With Femtotesla Sensitivity
Lu, F., Lu, J., Li, B., Yan, Y., Zhang, S., Yin, K., Ye, M., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3162282 · Cited by 27
Demagnetization Parameters Evaluation of Magnetic Shields Based on Anhysteretic Magnetization Curve
Yang, J., Shi, M., Zhang, X., Ma, Y., Liu, Y., Yuan, S., & Han, B. (2023) · Materials · doi:10.3390/ma16155238 · Cited by 24
“The great shielding effect can effectively reduce residual field and magnetic noise and obviously improve the signal-to-noise ratio of biological magnetic field measurement represented by magnetocardiogram (MCG) and magnetoencephalogram (MEG) [15,16].”
BackgroundVector magnetocardiography using compact optically-pumped magnetometers
Su, S., Xu, Z., He, X., Zhang, G., Wu, H., Gao, Y., Ma, Y., Yin, C., Ruan, Y., Li, K., et al. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e29092 · Cited by 26
“In most instances, MCG measurements solely record the magnetic field component that is perpendicular to the chest surface [3].”
BackgroundHan, X., Xue, X., Yang, Y., Liang, X., Gao, Y., Xiang, M., Sun, J., & Ning, X. (2023) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ace497 · Cited by 25
Indium Tin Oxide Non-Magnetic Heating Film for Miniaturized SERF Gradient Magnetometer
Liu, Z., Zhang, C., Yuan, H., Yin, K., Yang, Y., Yan, Y., Wang, Y., Zhou, B., Ning, X., & Han, B. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3076133 · Cited by 22
Suppression of modulation-magnetic-fields crosstalk for single-beam optically-pumped magnetometers
Suo, Y., Song, X., Jiang, L., Jia, L., Long, T., & Wu, Z. (2023) · Measurement · doi:10.1016/j.measurement.2023.113059 · Cited by 20
Hybrid optimal design method for magnetic field coils under magnetic shielding boundary
Wu, Z., Pang, H., Wang, Z., Fan, W., Liu, F., Pei, H., & Quan, W. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114464 · Cited by 20
Zhao, W., Tao, X., Ye, C., & Tao, Y. (2022) · Sensors · doi:10.3390/s22031021 · Cited by 20
“used the OPM sensor operating in the spin-exchange relaxation-free regime to construct a 16-channel MCG measurement system that can simultaneously image human cardiac activity on a large area of the chest in a single scan [10].”
MethodOptimal Design of Self-Shielded Biplanar Coil Assembly With Miniaturized Structure
Tang, S., Lu, J., Sun, B., Wang, S., Wang, K., Zhang, X., & Li, B. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3323002 · Cited by 20
“…in neural networks in order to map the neural oscillatory activity to the sensorimotor network and MCG is used to image the magnetic field from the cardiac electrical activity for diagnostics of various abnormal conditions of the heart such as arrhythmia, tachycardia, and heart attack [4], [5].”
MethodShi, M., Zhang, L., Zhang, X., Yang, J., Ma, Y., Zhang, A., & Yuan, S. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3555703 · Cited by 19
“The noticeable cases of ultrasensitive detection for medical applications are magnetocardiography (MCG) [2], [3], [4], [5], of which the weak biomagnetic signals arising from the physiology electrical activity of the cardiac are recorded and imaged in the extremely weak magnetic environment.”
Four-channel optically pumped magnetometer for a magnetoencephalography sensor array
Iivanainen, J., Carter, T. R., Dhombridge, J. E., Read, T. S., Campbell, K., Abate, Q., Ridley, D. M., Borna, A., & Schwindt, P. D. D. (2024) · Optics Express · doi:10.1364/oe.517961 · Cited by 18
Pang, H., Fan, W., Liu, F., Wu, Z., Yuan, Q., Du, P., Zhou, X., & Quan, W. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.114005 · Cited by 19
Hu, J., Liang, Z., Zhou, P., Liu, L., Hu, G., Du, P., & Ye, M. (2024) · Optics Letters · doi:10.1364/ol.527932 · Cited by 18
Han, X., Pang, J., Xu, D., Xie, F., Li, Y., Xiang, M., Sun, J., Chen, Y., & Ning, X. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.108764 · Cited by 21
A Single-Axis Atomic Magnetometer-Based Mouse Magnetocardiography Measurement System
Sun, Y., Xixi, W., Zhou, Y., Qin, J., Bai, D., Wang, Y., & Zhou, Z. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3265089 · Cited by 21
“cardiac magnetic field signals [17], [18], [19], [20], somatosen-”
BackgroundPortable single-beam cesium zero-field magnetometer for magnetocardiography
Dawson, R., O’Dwyer, C., Mrozowski, M. S., Irwin, E., McGilligan, J. P., Burt, D. P., Hunter, D., Ingleby, S. J., Rea, M., Holmes, N., et al. (2023) · Journal of Optical Microsystems · doi:10.1117/1.jom.3.4.044501 · Cited by 20
“32,33,38,39 Figure 7 shows the MCG setup for the cesium portable sensor.”
BackgroundZhang, S., Zhou, Y., Chai, Z., Liu, Q., Yin, K., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3232658 · Cited by 17
“devices (SQUIDs) for human biomagnetic measurements, such as magnetoencephalography (MEG) and magnetocardiography (MCG) [4], [15], [16], [17], [18], [20].”
BackgroundFree-induction-decay magnetic field imaging with a microfabricated Cs vapor cell
Hunter, D., Perrella, C., McWilliam, A., McGilligan, J. P., Mrozowski, M. S., Ingleby, S. J., Griffin, P. F., Burt, D., Luiten, A. N., & Riis, E. (2023) · Optics Express · doi:10.1364/oe.500278 · Cited by 19
Dead-zone-free atomic magnetometer based on hybrid Poincaré beams
Tian, K., Ding, W., & Wang, Z. (2024) · Photonics Research · doi:10.1364/prj.519409 · Cited by 17
Ding, Z., Huang, Z., & Han, B. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3239936 · Cited by 15
“and optically pumped magnetometer (OPM) [6], [7].”
Xu, Y., Chai, Z., Sun, J., Bai, D., Huang, K., Tian, Z., Cui, Z., & Pei, Y. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202300084 · Cited by 15
Ultra-high consistency multichannel SERF atomic magnetometer based on diffractive optics
Li, J., Liu, Y., Chai, Z., Cao, Q., Li, R., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114868 · Cited by 16
Xu, Y., Pei, H., Cong, Y., Li, X., Li, X., Pang, H., & Zhu, Z. (2024) · Measurement · doi:10.1016/j.measurement.2024.115960 · Cited by 14
Analysis and Correction of the Crosstalk Effect in a Three-Axis SERF Atomic Magnetometer
Yan, Y., Lu, J., Zhou, B., Wang, K., Liu, Z., Li, X., Wang, W., & Liu, G. (2022) · Photonics · doi:10.3390/photonics9090654 · Cited by 15
“Atomic magnetometers have been widely employed in medical diagnoses [1,2], biomagnetic measurements [3,4], and fundamental physics [5,6].”
BackgroundA synthetic optically pumped gradiometer for magnetocardiography measurements*
Zhang, S., & Cao, N. (2020) · Chinese Physics B · doi:10.1088/1674-1056/ab7801 · Cited by 14
Temperature characteristics of Rb-N2 single-beam magnetometer with different buffer gas pressures
Zhang, S., Zhou, Y., Lu, F., Yan, Y., Wang, W., Zhou, B., Zhai, Y., Lu, J., & Ye, M. (2023) · Measurement · doi:10.1016/j.measurement.2023.112860 · Cited by 13
Multi-channel MCG signals filtering method based on multivariate variational mode decomposition
Yang, K. Y., Xu, T., Pan, D., Zhang, Z., Wang, H., & Kong, X. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106806 · Cited by 13
A non-magnetic packaged Vertical-Cavity Surface-Emitting Laser for SERF magnetometers
Zhou, P., Zhang, G., Liang, Z., Hu, J., Liu, L., Hu, G., Wang, A., Du, P., & Ye, M. (2024) · Measurement · doi:10.1016/j.measurement.2024.116381 · Cited by 13
Approaching the Quantum Limit of Energy Resolution in Animal Magnetoreception
Kominis, I. K., & Gkoudinakis, E. (2025) · PRX Life · doi:10.1103/prxlife.3.013004 · Cited by 18
Li, R., Liu, Y., Li, J., Cao, Q., Huang, B., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114781 · Cited by 11
Li, J., Liu, Y., Li, R., Cao, Q., Zhou, T., & Zhai, Y. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.107231 · Cited by 11
Li, R., Liu, Y., Li, J., Cao, Q., Huang, B., & Zhai, Y. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.111217 · Cited by 11
Cui, Z., Wang, Y., Liu, Y., Jin, M., Sun, J., Zhai, Y., Zhou, X., & Chai, Z. (2024) · Nanophotonics · doi:10.1515/nanoph-2024-0309 · Cited by 14
“AMs are expected to replace superconducting quantum interference devices, particularly in bio-magnetic imaging including magnetoencephalography [6], [7] and magnetocardiography [8], [9].”
Li, R., Zhai, Y., Li, J., Cao, Q., & Liu, Y. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202300287 · Cited by 11
The Uncertainty Quantification for Parameters Optimization in SERF Atomic Magnetomer
Zhao, W., Li, Y., Wang, Y., Yan, Q., Song, Q., Wang, C., Kang, X., & Gao, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3116312 · Cited by 11
Quantum Thermodynamic Derivation of the Energy Resolution Limit in Magnetometry
Kominis, I. K. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.263201 · Cited by 14
“…about by superconducting sensors [18, 19] and optical pumping magnetometers [20, 21] have spurred numerous applications, like sensing magnetic fields produced by the human brain [22–26] or heart [27, 28], materials characterization [29, 30], even developing table-top probes of new physics [31–35].”
Dual-beam room-temperature atomic magnetometer with high sensitivity and large dynamic range
Liu, B., Peng, J., Wang, H., Fang, C., Wang, J., Zhao, X., & Deng, L. (2022) · Applied Physics Express · doi:10.35848/1882-0786/acaa1c · Cited by 10
A bell-bloom atomic magnetic-videorecorder with global shutter and differential readout
He, X., Dong, H., Hua, Z., Ye, H., Xu, C., Li, X., Guo, H., Li, Z., Wen, H. F., Tang, J., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01282-5 · Cited by 12
Xie, X., Zhou, X., Zhao, F., Wang, W., Yin, C., & Sun, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.117052 · Cited by 8
Pille, M., Gapelyuk, A., Berg, K., Bannasch, S., Mockler, J., Park, L.-S., Park, J.-W., & Wessel, N. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1276321 · Cited by 8
Kim, Y. J., & Savukov, I. (2020) · Journal of Applied Physics · doi:10.1063/5.0021284 · Cited by 8
Self-citationPractice and perspectives of using ultrasensitive magnetometers in biomedical research.
Maslennikov, Y. V. (2021) · Journal of Radio Electronics · doi:10.30898/1684-1719.2021.5.4 · Cited by 7
Spin-amplification SERF atomic magnetometer based on direct feedback
Ma, Y., Yuan, Z., Lin, S., Zhai, Y., & Tang, J. (2025) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-025-00378-7 · Cited by 7
In-situ measurement and cancellation of the light-shift in fiber-coupled atomic magnetometers
Zhao, B., Tang, J., Li, L., Zhang, Y., Li, C., Liu, Y., & Zhai, Y. (2022) · Optics Express · doi:10.1364/oe.476113 · Cited by 7
Measurement of T wave in magnetocardiography using tunnel magnetoresistance sensor
Lu, Z., Ji, S., & Yang, J. (2022) · Chinese Physics B · doi:10.1088/1674-1056/aca5fe · Cited by 7
In situ measurement of magneto-optical non-orthogonality in miniaturized atomic magnetometer
Li, R., Liu, Y., Cao, Q., Li, J., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114509 · Cited by 7
Pei, Y., Wang, C., Qin, J., Tong, Y., Wei, R., Weng, Y., Liu, F., Quan, W., Chai, Z., & Zhang, Y. (2025) · ACS Photonics · doi:10.1021/acsphotonics.4c02361 · Cited by 6
Xu, X., Zhai, Y., Zhao, B., Zhang, Y., Yue, Z., & Tang, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3612562 · Cited by 7
“Alternatively, some works have directly utilized an expanded beam to illuminate a photodiode array [26], [27], [28], realizing mm-level spatial resolution for multichannel magnetic field detection.”
Recent advances and applications on fiber-optic scalar and vector magnetometers
Kumar, A., & Baac, H. W. (2025) · Applied Physics Reviews · doi:10.1063/5.0222078 · Cited by 6
Multifunctional Metafiber for Pumping SERF Atomic Magnetometer
Song, Q., Luan, W., Liu, Y., Duan, L., & Yu, X. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3571149 · Cited by 5
“…to the distinct advantages in enhancing spatial resolution as well as reducing volume and power consumption [8], miniaturized SERF atomic magnetometers are particularly attractive for biomagnetic measurements such as magnetoencephalography (MEG) [9], [10] and magnetocardiography (MCG) [11], [12].”
Gao, S., Han, B., Li, X., Liu, Z., Wang, Z., Sheng, J., & Lu, J. (2025) · Advanced Quantum Technologies · doi:10.1002/qute.202500424 · Cited by 5
Chen, Y., Wang, J., Zhang, N., Wang, J., Ma, Y., Yu, M., Wang, Y., Zhao, L., & Jiang, Z. (2023) · Micromachines · doi:10.3390/mi14111985 · Cited by 5
Crosstalk Reduction for Mz/Mx Magnetometer Array
Yang, K., Xu, T., Pan, D., Guo, H., Zhou, S., Cai, Y., & Kong, X. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3474214 · Cited by 5
Ito, Y., Ueda, H., Oida, T., Moriya, T., Saito, A., & Suyama, M. (2024) · Scientific Reports · doi:10.1038/s41598-024-77089-z · Cited by 6
Karabinaoğlu, M. S., Caklı, B. M., & Sevim, M. H. (2025) · IEEE Sensors Letters · doi:10.1109/lsens.2025.3544963 · Cited by 5
“Some of the applications of OPMs are magnetoencephalography (MEG) [8], [9], [10], magnetocardiography [11], [12], [13], high-precision fundamental measurements [14], spin detection [15], [16], [17], anomalous spin forces and NMR detection in microfluidic chips [18], [19], [20], [21], position…”
The suppression of magnetic noise in a magnetic shielding unit for atomic sensor applications
Karabinaoğlu, M. S., Günay, E., Çakır, B., Caklı, B. M., & Sevim, M. H. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116833 · Cited by 4
Theoretical study of the close-loop atomic magnetometer with a transverse pumping feedback
Shi, M., & Dong, H. (2021) · Measurement Science and Technology · doi:10.1088/1361-6501/ac284d · Cited by 4
Jie, S., & Liu, Z. (2024) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ad518c · Cited by 4
“…instruments because of their low intrinsic noise, miniaturization, and low power consumption, such as spin-exchange relaxation-free atomic magnetometers [1, 2], nuclear magnetic resonance (NMR) angular velocity sensors [3, 4], atomic clocks [5, 6] and many fundamental physics experiments [7, 8].”
Xie, X., Zhou, X., Zhao, F., Wang, W., Yin, C., & Sun, J. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad7234 · Cited by 4
Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity
Chen, J., Ye, C., Hou, X., Niu, Y., & Sun, L. (2025) · Sensors · doi:10.3390/s25020433 · Cited by 4
Advances in laser heating of alkali vapor cells in magnetometers: a review
Wang, K., Zhou, B., Tang, J., Zhang, S., & Wang, Y. (2020) · Applied Optics and Photonics China (AOPC) · doi:10.1117/12.2574588 · Cited by 5
High-sensitive magnetometric measuring systems for biomagnetic imaging, recording and diagnostics
Maslennikov, Y. V. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822532-5.00019-4 · Cited by 4
Optimization design of different induction magnetometers for MCG
Huang, Z., Wang, Q., & Ding, Z. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.116192 · Cited by 3
Zhu, C., Zhang, X., Xiang, M., Qu, C., Jia, Y., Yang, J., Tian, K., Cao, Y., Pang, J., & Li, J. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3639748 · Cited by 3
“Recent advances in equipment, including optically pumped mag-netometer (OPM) technology [7], [8], [9] and high-performance magnetic shielding [10], [11], [12], have provided essential support for acquiring high-precision MCG signals, renewing interest in MCG among researchers.”
High‐Efficiency Liquid‐Crystal Polarization Metalens for Chip‐Scale Atomic Magnetometers
Cui, Z., Pan, J., Tao, X., Hu, J., Hou, G., Zhang, Z., Ye, M., Zhou, X., Lu, Y., Chai, Z., et al. (2025) · Laser & Photonics Review · doi:10.1002/lpor.202502517 · Cited by 2
Ma, C., Pang, J., Wang, R., Xu, D., Xiang, M., & Wang, Z. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3486119 · Cited by 3
“However, with the rise in the number of MCG channels—from 15 channels [10], 16 channels [11], 36 channels [12], 37 channels [13], 64 channels [6], to as many as 81 channels [14]—the volume of available cardiac information obtained also escalates.”
Recording the Distribution of Cardiac Magnetic Fields in Unshielded Earth’s Field
Sun, C., Xiao, W., Ding, Y., Zhang, R., Liu, M., Wu, T., Peng, X., Chen, J., & Guo, H. M. (2021) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs52194.2021.9604275 · Cited by 5
Jie, S., Liu, Z., Wang, J., Zhang, S., & Zhao, K. (2024) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2024.107634 · Cited by 3
A practical approach to calculating magnetic Johnson noise for precision measurements
Phan, N., Clayton, S. M., Kim, Y. J., & Ito, T. M. (2024) · Journal of Applied Physics · doi:10.1063/5.0228845 · Cited by 4
Self-citationDynamic Response of a Light-Modulated Magnetometer to Time-Dependent Fields
Bevilacqua, G., Biancalana, V., & Dancheva, Y. V. (2023) · Atoms · doi:10.3390/atoms11080111 · Cited by 2
Miao, K., Hu, T., Chang, Y., Zhang, K., & Yang, X. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3521412 · Cited by 3
“Therefore, SERF AMs have become a promising alternative to SQUID, particularly in the realm of biomagnetism [28], encompassing MEG [29].”
SERF magnetometer array using concurrent amplitude-stabilized optical modulation
Yue, Z., Zhai, Y., Wang, Y., Xu, X., & Tang, J. (2025) · Alexandria Engineering Journal · doi:10.1016/j.aej.2025.05.057 · Cited by 2
Towards a multi-channel zero-field optically pumped magnetometer for imaging
Rasser, R., Koss, P. A., Knappe, S. A., & Buse, K. (2025) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-025-00400-y · Cited by 2
Fast magnetic field imaging using an optically pumped magnetometer readout by a high-speed camera
Gutekunst, J., Rasser, R., Blug, A., & Koss, P. A. (2025) · Journal of Applied Physics · doi:10.1063/5.0304863 · Cited by 2
Fe‐Based Nanocrystalline Magnetic Shielding Cylinder with Subfemtotesla‐Level Magnetic Noise
Shen, P., Ma, D., Wang, K., Li, S., Gao, Y., Wang, P., Yuan, F., Chen, H., Wang, Z., Liu, Z., et al. (2026) · Advanced Science · doi:10.1002/advs.202522435 · Cited by 2
Metadata
- Authors
- Kim, Y. J., Savukov, I., & Newman, S.
- Affiliations
- Los Alamos National Laboratory (US)
- Corresponding author
- Kim, Young Jin
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2019-04-08
- Volume
- 114
- Issue
- 14
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2935860139
- Cited by
- 133
- References
- 15
- Citations by year
- 2026: 18 · 2025: 26 · 2024: 25 · 2023: 26 · 2022: 17 · 2021: 16 · 2020: 5
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor, 4 d)
- creativecommons.org/licenses/by/4.0/ (tdm, 4 d)
- Locations
- Applied Physics Letters (publishedVersion, cc-by)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- Los Alamos National Laboratory (20180131ER)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Keywords
- magnetocardiography, optically pumped magnetometers, rubidium vapor cell, spin-exchange relaxation-free, low-cost sensors, magnetic shielding
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.