Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We have constructed a low-cost, portable, high-sensitivity 16-channel optically pumped magnetometer (OPM), operating in the spin-exchange relaxation-free regime, and demonstrated its applications in magnetocardiography (MCG). The decrease in the cost of sensors by an order of magnitude is achieved by the 16-channel operation realized in a single module using a single large flat pancake rubidium vapor cell, broad pump and probe laser beams, and a 16-channel photodiode array. The OPM is also based on a fiber-coupled nearly parallel-beam configuration to facilitate multichannel design and make the system portable. For human MCG experiments, the 16-channel OPM which includes optical components is placed inside a wooden enclosure for laser safety. The enclosure is set on a nonmagnetic table inside a magnetically shielded room, while the lasers and electronics are placed outside the shielding room, to avoid magnetic noise. We show that the 16-channel OPM enables simultaneous imaging of human cardiac activity on a large area of the chest in a single scan. The multichannel capability will accelerate clinical MCG imaging to reduce the procedure time and patient fatigue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The MCG measurements usually require the participant keeping still in a magnetically shielded room due to the immovable sensor and noisy external environments.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [36]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Previously, biomagnetic signal measurements based on OPMs are often performed in magnetically shielded environments (35, 36) due to the magnetic field noise from surroundings. Despite there being several works on unshielded biomagnetic signal measurements (35, 37), these shielded or unshielded measurements normally require the participant to remain still during the measurement.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [36]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
Seltzer, S. J., & Romalis, M. V. (2004) · Applied Physics Letters · doi:10.1063/1.1814434 · Cited by 320
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
A laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185
Multi-channel atomic magnetometer for magnetoencephalography: A configuration study
Kim, K., Begus, S., Xia, H., Lee, S.-K., Jazbinsek, V., Trontelj, Z., & Romalis, M. V. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.040 · Cited by 170
Multichannel biomagnetic system for study of electrical activity in the brain and heart
Schneider, S., Hoenig, E., Reichenberger, H., Abraham-Fuchs, K., Moshage, W., Oppelt, A., Stefan, H., Weikl, A., & Wirth, A. (1990) · Radiology · doi:10.1148/radiology.176.3.2389043 · Cited by 74
Kim, Y. J., Chu, P.-H., & Savukov, I. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.091802 · Cited by 67
Self-citation
Cited by
Items 101–133 of 133
Ma, Y., Shi, M., Zhang, L., Li, T., Ling, X., Yuan, S., Wang, H., & Gao, Y. Q. (2024) · Materials · doi:10.3390/ma17235906 · Cited by 1
“In medical and biomedical science [12], in the research on weak biomagnetic signal recording, such as magnetoencephalography and magnetocardiograms [13,14], the target signal is extremely weak and easily disturbed by surrounding magnetic interference.”
Ultra-thin pancake beam expanding collimator with metalens for atomic magnetometer
Qin, J., Chai, Z., Xu, Y., Xu, Y. L., Su, X., Huang, K., & Meng, X. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.114039 · Cited by 1
Zhou, P., Xu, F., Liang, Z., Hu, J., Liu, L., Hu, G., Hou, G., Xu, Y., & Ye, M. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.114250 · Cited by 2
Robust Vector Decoupling of SERF Magnetometers Using Artificial Neural Network
Yu, B., Qin, J., Li, J., Wang, B., Zhang, X., Jiang, Z., & Qu, J. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3651429 · Cited by 2
“…magnetometers have been demonstrated in wearable magnetoencephalography (MEG) systems [3], [4], [5], [6], magnetocardiography (MCG) monitoring [7], [8], [9], [10], and precision tests of fundamental physics [11], [12], Their compact design and low size-weight-power (SWaP) demands continue to drive…”
Response Model of Naturally Abundant Rubidium SERF Magnetomete
Sheng, J., Li, X., Liu, Z., Wang, Z., Gao, S., & Lu, J. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3654698 · Cited by 1
“In recent years, they have been utilized in magnetocardiography (MCG) and magnetoencephalography (MEG) [5], [6], where 64-or 128-channel array implementations have been developed [7], [8].”
Peng, G., Shi, J., Zhang, H., Jiao, Q., Jin, Z., & Chen, J. (2026) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2026.100975 · Cited by 1
Spin-Feedback-Enhanced Atomic Magnetic Gradiometer
Ma, Y., Lin, S., Yuan, Z., Zhai, Y., & Tang, J. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3704257 · Cited by 1
“…operating in the spin-exchange relaxation-free (SERF) regime have demonstrated exceptional sensitivity for magnetic field detection [1], [2], [3], which makes them crucial for applications such as fundamental physics research [4], [5], [6], [7] and biomagnetic applications [8], [9], [10], [11].”
Niu, H., Huang, Z., Pang, M., Yuan, Y., Li, Y., & Zhang, J. (2026) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2026.3712004 · Cited by 1
“Current MCG research devices frequently adopt uniform layouts with empirically defined sampling spacing and coverage [19], [20].”
Chen, Y., Muhammad, J.-A., Zhao, Y., Kang, C., & Zhang, J. (2021) · Journal of the Korean Physical Society · doi:10.1007/s40042-021-00185-0 · Cited by 1
Time response of spin-polarized rubidium thermal gas with radio-frequency pulse driving
Wang, Y., Kang, Z., Li, Y., Ma, Q., Wang, Y., Dong, Y., & Wang, J. (2022) · Journal of Applied Physics · doi:10.1063/5.0082535 · Cited by 1
Yan, Y., Lu, J., Wang, K., Lu, F., Zhang, S., Liu, Z., Li, X., & Zhou, B. (2024) · Chinese Optics Letters · doi:10.3788/col202422.101201 · Cited by 1
“Therefore, the SERF atomic mag-netometer has been increasingly applied to biomagnetic measurements such as magnetocardiography (MCG) [13,14] , magnetoencephalography (MEG) [15 – 17] , and magnetopneu-mography (MPG) [18] .”
Zhan, D., Wang, Y., Liu, Z., Yan, Y., Wu, Y., Hu, Z., & Lu, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3551928 · Cited by 2
“…(SERF) magnetometers have realized measurement sensitivity of sub-femtotesla (fT) order [2], [3], thus becoming one of the most promising magnetometers for application in biomedical magnetic measurement [4], [5], [6], materials characterization [7], and fundamental physics research [8], [9].”
Broadband Ultra-Sensitive Adiabatic Magnetometer
Savukov, I., & Kim, Y. J. (2021) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas51076.2021.9530142 · Cited by 2
Self-citationA single beam Cs-Ne SERF magnetometer with differential laser power noise suppression methodPreprint
Chen, Y., Ma, Y., Yu, M., Zhang, N., Zhao, L., Han, X., & Jiang, Z. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2101.01811 · Cited by 2
“The application includes magnetoencephalography(MEG) [1,3, 4] and magnetocardiography(MCG) [11,18,22],rotation sensing [5,9,13], testing physics beyond the standard model: anomalous spin forces detection [8,19,20], low field NMR detection in a micro-fluid chip [10],etc.”
MethodTwo-quantum magnetic resonance driven by a periodic RF pulse train
Tsygankov, E. A., Vaskovskaya, M. I., Chuchelov, D. S., Sabakar, K. M., Vassiliev, V. V., & Zibrov, S. A. (2023) · Journal of the Optical Society of America B · doi:10.1364/josab.501179
Detuned square-wave optical modulation zero-field atomic magnetometer
Li, X., Han, B., Lu, J., Liu, Z., & Yan, Y. (2023) · Optics Young Scientist Summit (OYSS) · doi:10.1117/12.3015902
“Due to the advantages of no cooling, easy miniaturization and wearable, there has been a surge of research on the technology and application of micro-miniature zero-field atomic magnetometers at home and abroad in recent years [8,9,10].”
BackgroundDONG, 董. Y.-B., REN, 任. L., LIU, 刘. B., ZHANG, 张. R.-S., YANG, 杨. L., KANG, 康. Z.-H., Qiang, 马., & WANG, 王. Y.-H. (2024) · Acta Sinica Quantum Optica · doi:10.3788/jqo20243001.0501
Kexuan, 缪. M., Tao, 胡. H., Qingqian, 郭. G., Xiaoyu, 冯. F., Yin, 张. Z., Yan, 常. C., & Xiaodong, 杨. Y. (2024) · Chinese Journal of Lasers · doi:10.3788/cjl240503
Miniaturized atomic magnetometer employing pump-beam modulation
Yue, Z., Tang, J., & Zhai, Y. (2024) · Advanced Sensor Systems and Applications · doi:10.1117/12.3035399
“Moreover, SERF magnetometers offer additional advantages, including flexible configurations and potential for miniaturization[12,13], making them highly suitable for array-based high spatially resolved measurements in medical imaging applications, specifically for magnetocardiography (MCG) and…”
Jing, Z., Zhang, H., & Zhao, F. (2025) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon58223.2025.11221386
Recent advances in magnetocardiography
Kong, X., Yang, K., Zhang, Z., Pan, D., & Guo, C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-41624-8.00001-2 · Cited by 2
Miniaturized Dual-Beam SERF Magnetometer Using Natural Abundance Rubidium
Sheng, J., Liu, Z., Li, X., Wang, Z., Gao, S., & Lu, J. (2025) · IEEE International Conference on Electronic Measurement & Instruments · doi:10.1109/icemi66537.2025.11306847
Yuan, L., Cui, P., Zhang, H., Zhao, F., Qiu, S., & Zheng, S. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3650250
“M AGNETOCARDIOGRAPHY (MCG) is a radiation-free, noninvasive, and contrast media-free medical imaging technique [1], [2].”
Dual resonances induced by amplitude-modulated light in a spin-exchange relaxation-free magnetometer
Yue, Z., Li, L., Xu, X., Wang, Y., Zhai, Y., & Tang, J. (2026) · Optics Express · doi:10.1364/oe.587988
Zero-field atomic magnetometer unaffected by longitudinal magnetic field interference
Zhan, D., Wang, Y., Liu, Z., Yan, Y., Hu, Z., & Lu, J. (2026) · Measurement · doi:10.1016/j.measurement.2026.121188
Subensemble correlations as a covariance geometry
Wang, Z., Zhang, Y., Hou, G., Liang, Z., Hu, G., Liu, L., Sun, Y., Xu, F., & Ye, M. (2026) · Physical Review A · doi:10.1103/5s4b-kw34
Cui, Z., Xiao, X., Wei, Z., Fu, Z., Huang, K., Pei, L., Zhou, X., Chai, Z., & Bai, D. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01297-y
Optimal and efficient inference tools for field tracking with precessing spins
Anonymous, Bania, P., Méndez-Avalos, D., Sierant, A., Mitchell, M. W., & Kołodyński, J. (2026) · Physical Review Applied · doi:10.1103/jfhj-kr1j
“These features enable emerging technologies such as magnetic navigation in GPS-denied environments [10, 11], ultra-low-field NMR [12] and MRI [13], and materials characterisation [14], as well as medical applications for sensing brain (MEG [15]) or heart (MCG [16, 17]) signals.”
Magnetic field camera for zero-field conditions
Rasser, R., Koß, P., Knappe, S., & Buse, K. (2026) · Optics Express · doi:10.1364/oe.597712 · Cited by 1
Cui, Z., Wang, C., Zhou, X., Hou, G., Hu, J., Ye, M., Xiao, X., Chai, Z., Weng, Y., & Zhang, Y. (2026) · Advanced Science · doi:10.1002/advs.77320
Pulsed-Modulation Single-Beam Three-Axis Atomic Magnetometer
Gao, S., Li, X., Sheng, J., Wang, Z., Xu, G., Wang, Z., Han, B., & Lu, J. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3731755
“These bandwidths are su ffi cient to meet the requirements for biomagnetic signal detection, such as the 1–40-Hz signal frequency range of MCG and the 1–70-Hz range of MEG [39], [40].”
Human cardiac measurements with diamond magnetometers
Omar, M., Benke, M., Zhang, S., Zhang, J., Wang, Y., Kübler, M., Sharbati, P., Rahimpour, A., Gueck, A., Kapitonova, M., et al. (2026) · Science Advances · doi:10.1126/sciadv.aeg5281 · Cited by 8
“The measured MCG peak amplitudes between OPM and diamond sensor were comparable and consistent with values in the literature [25–27].”
He, Y., Zhang, X., Han, X., Zhang, Z., Zheng, S., Tian, K., & Xiang, M. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1960096
“Recent studies increasingly focus on SERF and other room-temperature OPM implementations, including multichannel array design and system integration (91 – 93).”
Metadata
- Authors
- Kim, Y. J., Savukov, I., & Newman, S.
- Affiliations
- Los Alamos National Laboratory (US)
- Corresponding author
- Kim, Young Jin
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2019-04-08
- Volume
- 114
- Issue
- 14
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2935860139
- Cited by
- 133
- References
- 15
- Citations by year
- 2026: 18 · 2025: 26 · 2024: 25 · 2023: 26 · 2022: 17 · 2021: 16 · 2020: 5
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (vor, 4 d)
- creativecommons.org/licenses/by/4.0/ (tdm, 4 d)
- Locations
- Applied Physics Letters (publishedVersion, cc-by)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- Los Alamos National Laboratory (20180131ER)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Keywords
- magnetocardiography, optically pumped magnetometers, rubidium vapor cell, spin-exchange relaxation-free, low-cost sensors, magnetic shielding
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.