Portable intrinsic gradiometer for ultra-sensitive detection of magnetic gradient in unshielded environment
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We demonstrate a portable all-optical intrinsic scalar magnetic gradiometer composed of miniaturized cesium vapor cells and vertical-cavity surface-emitting lasers (VCSELs). Two cells, with inner dimensions of 5 mm × 5 mm × 5 mm and separated by a baseline of 5 cm, are driven by one VCSEL, and the resulting Larmor precessions are probed by a second VCSEL through optical rotation. The off-resonant linearly polarized probe light interrogates two cells at the same time, and the output of the intrinsic gradiometer is proportional to the magnetic field gradient measured over the given baseline. This intrinsic gradiometer scheme has the advantage of avoiding added noise from combining two scalar magnetometers. We achieve a sensitivity better than 18 fT/cm/√Hz in the gradient measurement. Ultra-sensitive short-baseline magnetic gradiometers can potentially play an important role in many practical applications, such as nondestructive evaluation and unexploded ordnance detection. Another application of the gradiometer is for magnetocardiography (MCG) in an unshielded environment. Real-time MCG signals can be extracted from the raw gradiometer readings. The demonstrated gradiometer greatly simplifies the MCG setup and may lead to a ubiquitous MCG measurement in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“Sensitivities comparable with [2] or even outperforming [3] those of superconducting quantum interference devices (SQUIDs) have been reported with SERF magnetometers.”
BackgroundHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“For example, the discovery of the spin-exchange relaxation-free (SERF) phenomenon at high atomic density and low magnetic field leads to a great improvement in the magnetometer noise performance [1].”
BackgroundUltrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621 · cited 3×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodChip-scale atomic magnetometer
Schwindt, P. D. D., Knappe, S., Shah, V., Hollberg, L., Kitching, J., Liew, L.-A., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1839274 · Cited by 481 · cited 3×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodSubfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364 · cited 1×
“With bigger cells, scalar magnetometers can reach sensitivities of sub-10 fT/√Hz [10] or even sub-fT/√Hz [11].”
BackgroundA laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185 · cited 1×
“With the bandwidth of over 100 Hz, the gradiometer can be used for many applications such as nondestructive evaluation [20], unexploded ordnance (UXO) detection [21] and magnetocardiography (MCG) in an unshielded environment [22, 23, 24, 25].”
MethodChip-scale atomic magnetometer with improved sensitivity by use of the Mx technique
Schwindt, P. D. D., Lindseth, B., Knappe, S., Shah, V., Kitching, J., & Liew, L.-A. (2007) · Applied Physics Letters · doi:10.1063/1.2709532 · Cited by 183 · cited 3×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodAlem, O., Sander, T. H., Mhaskar, R., LeBlanc, J., Eswaran, H., Steinhoff, U., Okada, Y., Kitching, J., Trahms, L., & Knappe, S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/12/4797 · Cited by 182 · cited 1×
“With the bandwidth of over 100 Hz, the gradiometer can be used for many applications such as nondestructive evaluation [20], unexploded ordnance (UXO) detection [21] and magnetocardiography (MCG) in an unshielded environment [22, 23, 24, 25].”
MethodSelf-citationA low-power, high-sensitivity micromachined optical magnetometer
Mhaskar, R., Knappe, S., & Kitching, J. (2012) · Applied Physics Letters · doi:10.1063/1.4770361 · Cited by 171 · cited 3×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodSelf-citation
Cited by
Sensitive magnetometry in challenging environments
Fu, K. C., Iwata, G. Z., Wickenbrock, A., & Budker, D. (2020) · AVS Quantum Science · doi:10.1116/5.0025186 · Cited by 132
Integrated Optically Pumped Magnetometer for Measurements within Earth’s Magnetic Field
Oelsner, G., IJsselsteijn, R. P. J., Scholtes, T., Krüger, A., Schultze, V., Seyffert, G., Werner, G. R., Jäger, M., Chwala, A., & Stolz, R. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.024034 · Cited by 107
“[21] Rui Zhang, Rahul Mhaskar, Ken Smith, and Mark Prouty, “Portable intrinsic gradiometer for ultra-sensitive detection of magnetic gradient in unshielded environment,” Applied Physics Letters 116, 143501 (2020).”
BackgroundFemtotesla Direct Magnetic Gradiometer Using a Single Multipass Cell
Lucivero, V. G., Lee, W., Dural, N., & Romalis, M. V. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.014004 · Cited by 77
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
SQUIDs for magnetic and electromagnetic methods in mineral exploration
Stolz, R., Schiffler, M., Becken, M., Thiede, A., Schneider, M., Chubak, G., Marsden, P., Bergshjorth, A. B., Schaefer, M. O., & Terblanche, O. (2022) · Mineral Economics · doi:10.1007/s13563-022-00333-3 · Cited by 65
Scalar Magnetometry Below 100 fT/Hz1/2 in a Microfabricated Cell
Gerginov, V. P., Pomponio, M., & Knappe, S. A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3002193 · Cited by 59
“An intrinsic gradiometer configuration [40] can also be used, in which the photon shot noise will be common-mode.”
Femtotesla Nearly-Quantum-Noise-Limited Pulsed Gradiometer at Earth-Scale Fields
Lucivero, V. G., Lee, W., Limes, M. E., Foley, E. L., Kornack, T. W., & Romalis, M. V. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.l021001 · Cited by 60
Perry, A. R., Bulatowicz, M. D., Larsen, M., Walker, T. G., & Wyllie, R. (2020) · Optics Express · doi:10.1364/oe.408486 · Cited by 39
A study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding
Clancy, R. J., Gerginov, V., Alem, O., Becker, S., & Knappe, S. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac18fb · Cited by 37
“Work has begun on detecting brain signals in unshielded environments (Limes et al 2020b, Zhang et al 2020).”
BackgroundMethodJaufenthaler, A., Kornack, T. W., Lebedev, V., Limes, M. E., Körber, R., Liebl, M., & Baumgarten, D. (2021) · Sensors · doi:10.3390/s21041212 · Cited by 36
Evolution of MEG : A first MEG ‐feasible fluxgate magnetometer
Koshev, N., Butorina, A. V., Skidchenko, E., Kuzmichev, A. N., Ossadtchi, A. E., Ostras, M., Fedorov, M. V., & Vetoshko, P. M. (2021) · Human Brain Mapping · doi:10.1002/hbm.25582 · Cited by 35
Zhang, J., Liu, K., Zhang, J., Wang, Z., & Shang, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3120375 · Cited by 33
A novel low-noise Mu-metal magnetic shield with winding shape
Ma, D., Lu, J., Fang, X., Dou, Y., Wang, K., Gao, Y., Li, S., & Han, B. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113884 · Cited by 29
High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer
Yao, H., Maddox, B., & Renzoni, F. (2022) · Optics Express · doi:10.1364/oe.476016 · Cited by 34
“This limitation is usually overcome by operating the atomic magnetometer in a magnetically shielded environment or, in case of spatially rapidly decaying field, by the use of differential measurements with a multiple sensor set-up [2,3,9–17].”
Zhao, W., Tao, X., Ye, C., & Tao, Y. (2022) · Sensors · doi:10.3390/s22031021 · Cited by 21
“A gradiometer was developed for weak magnetic field measurement, which could reduce the common noise [12,13].”
BackgroundFast measurement of spin-exchange relaxation in the range of earth-scale magnetic field
Fang, C., Jiang, L., Liu, J., Zhu, J., Shao, Q., Pei, H., & Quan, W. (2023) · Measurement · doi:10.1016/j.measurement.2023.113449 · Cited by 20
An optically pumped magnetic gradiometer for the detection of human biomagnetism
Cook, H., Bezsudnova, Y., Koponen, L. M., Jensen, O. B., Barontini, G., & Kowalczyk, A. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad3d81 · Cited by 24
“In this work, we realise an intrinsic OPMG based on non-linear magneto-optical rotation (NMOR).”
MethodVector measurements using all optical scalar atomic magnetometers
Zhang, R., Mhaskar, R. R., Smith, K. A., Balasubramaniam, E., & Prouty, M. D. (2021) · Journal of Applied Physics · doi:10.1063/5.0037991 · Cited by 17
“Better than 300 fT/√Hz sensitivities have been achieved in miniaturized vapor cells [3, 4, 5, 6] and with bigger cells much better sensitivities have been demonstrated [7, 8, 9, 10, 11, 12, 13, 14].”
BackgroundSelf-citationA Benchmark of Integrated Magnetometers and Magnetic Gradiometers
Brajon, B., Gasparin, E., & Close, G. F. (2023) · IEEE Access · doi:10.1109/access.2023.3325035 · Cited by 18
“The gradiometric configuration enables sensor operation in an unshielded room, despite the minute fields (100 pT), as demonstrated in [7].”
MethodDong, H., Ye, H., Hu, M., & Ma, Z. (2023) · Micromachines · doi:10.3390/mi15010059 · Cited by 15
“The probe path of an intrinsic, scalar, optically pumped gradiometer using a half-wave plate to reverse optical rotation [59].”
BackgroundMethodInfluentialIntrinsic radio-frequency gradiometer
Cooper, R. J., Prescott, D. W., Sauer, K. L., Dural, N., & Romalis, M. V. (2022) · Physical Review A · doi:10.1103/physreva.106.053113 · Cited by 14
A high performance active noise control system for magnetic fields
Pyragius, T., & Jensen, K. (2021) · Review of Scientific Instruments · doi:10.1063/5.0062650 · Cited by 19
Yttrium-Iron Garnet Magnetometer in MEG: Advance towards Multi-Channel Arrays
Skidchenko, E., Butorina, A. V., Ostras, M., Vetoshko, P. M., Kuzmichev, A. N., Yavich, N. B., Malovichko, M., & Koshev, N. (2023) · Sensors · doi:10.3390/s23094256 · Cited by 16
Large-scale multipass two-chamber rf atomic magnetometer
Heilman, D. J., Sauer, K. L., Prescott, D. W., Motamedi, C. Z., Dural, N., Romalis, M. V., & Kornack, T. W. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.054024 · Cited by 13
Optimizing longitudinal spin relaxation in miniaturized optically pumped magnetometers
McWilliam, A., Dyer, S., Hunter, D., Mrozowski, M. S., Ingleby, S. J., Sharp, O., Burt, D. P., Griffin, P. F., McGilligan, J. P., & Riis, E. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.064024 · Cited by 9
Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure
Wu, Z., Zhang, J., Chen, W., Ou, Z., Yue, H., Cheng, C., & Liu, Y. (2024) · Optics Letters · doi:10.1364/ol.518697 · Cited by 8
Modulation crosstalk effect analysis on single-beam SERF atomic magnetic gradiometer
Chen, T., Zheng, Z., Zhang, J., Chen, Z., Chen, W., Ou, Z., Yue, H., & Liu, Y. (2025) · Measurement · doi:10.1016/j.measurement.2025.117782 · Cited by 8
Magnetic field sensing based on multi-order resonances of atomic spins
Yang, H., Wang, Q., Zhao, B., Li, L., Zhai, Y., Han, B., & Tang, F. (2021) · Optics Express · doi:10.1364/oe.443679 · Cited by 6
Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands
Campbell, K., Wang, Y.-J., Savukov, I., Schwindt, P. D. D., Jau, Y., & Shah, V. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.163602 · Cited by 4
A compact unshielded optically pumped magnetic gradiometer
Ye, H., Xu, C., Hu, M., & Dong, H. (2025) · Review of Scientific Instruments · doi:10.1063/5.0233804 · Cited by 4
Characteristic analysis and blind area prediction of aeromagnetic scalar gradient detection method
Chang, M., Xu, L., Pang, X., Zhang, J., Li, H., & Lin, M. (2022) · AIP Advances · doi:10.1063/5.0102139 · Cited by 3
Yao, H., & Renzoni, F. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3608340 · Cited by 3
“Inspired by Zhang et al. [19], we measured both the signal amplitude spectrum (AS) and the signal amplitude spectral density (ASD) with the RF field on and took the value of the detuned signal (ASD (cid:48) ) as the noise level, as reported in Table I.”
Status and future perspectives of airborne magnetic gradiometry
Stolz, R., Schiffler, M., Zakosarenko, V., Larnier, H., Rudd, J., Chubak, G., Polomé, L., Pitts, B., Schneider, M., Schulz, M., et al. (2021) · Second International Meeting for Applied Geoscience & Energy · doi:10.1190/segam2021-w6-05.1 · Cited by 4
Fiber-Coupled OPM in Purely Coil-Shielded Environment
Wu, T., Peng, X., Chen, J., & Guo, H. M. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_9 · Cited by 2
Single-Beam, Dual-Channel Self-Oscillating Optically Pumped Magnetometer
Wang, X., Fu, Y., Yu, H., Zhang, X., Wang, H., & Zheng, W. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3637032 · Cited by 1
“Compared with the typical magnetic gradiometer structure that employs at least two laser beams to illuminate two separate cells [14], [15], [16], [17], this single-beam configuration enables a more compact sensor probe.”
Assessment of Relaxation Components in Optically Pumped Magnetometers Under Operational Conditions
Zhou, H., Zhangu, Y., Li, J., Xuan, Y., Zhu, R., & Zhu, Z. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3654695 · Cited by 2
“In addition to the aforementioned parameters, the magnetic resonance linewidth ∆ x FWHM serves as a key parameter for extracting relaxation information in the proposed relaxation measurement method, as described by (7).”
Simulation of Scalar-Mode Optically Pumped Magnetometers to Search Optimal Operating Conditions
Ito, Y., Tatsuya, G. O. T. O., & Takuma, H. O. R. I. (2023) · IEICE Transactions on Electronics · doi:10.1587/transele.2023sei0002 · Cited by 1
“To solve this problem, many attempts have been made in recent years to realize biomagetic-field measurements in Earth’s ambient fields [4], [5].”
BackgroundDesign of an Integrated MEMS Magnetic Gradiometer Rejecting Vibrations and Stray Fields
Gasparin, E., Hoogerwerf, A. C., Bayat, D. Z., Durante, G. S., Pétremand, Y., Tormen, M., Despont, M., & Close, G. F. (2025) · IEEE Journal of the Electron Devices Society · doi:10.1109/jeds.2025.3543662 · Cited by 1
“In this application, the characteristic length scale is a few cm, and so is d [7], [8], [9].”
Бобров, М. А., Блохин, С. А., Малеев, Н. А., Кузьменков, А. Г., Блохин, А. А., Васильев, А. П., Кулагина, М. М., Pazgalev, A. S., Новиков, И. И., Карачинский, Л. Я., et al. (2021) · Письма в журнал технической физики · doi:10.21883/pjtf.2021.24.51789.18940 · Cited by 1
Perry, A. R., Bulatowicz, M., Larsen, M., Walker, T. G., & Wyllie, R. (2020) · arXiv (Cornell University)
Bobrov, M. A., Blokhin, S. A., Maleev, N. A., Kuzmenkov, A. G., Blokhin, A. A., Vasilyev, A. P., Kulagina, M. M., Pazgalev, A. S., Novikov, I. I., Ya., K. L., et al. (2022) · Письма в журнал технической физики · doi:10.21883/tpl.2022.15.54264.18940
Yudanov, N. A., Nemirovich, M. A., Andreiko, M. A., Makhnovskiy, D. P., Rodionova, V. V., & Panina, L. V. (2023) · Izmeritel`naya Tekhnika · doi:10.32446/0368-1025it.2023-11-38-44
Bobrov, M. A., Blokhin, S. A., Maleev, N. A., Kuzmenkov, A. G., Blokhin, A. A., Vasilyev, A. P., Kulagina, M. M., Pazgalev, A. S., Novikov, I. I., Karachinsky, L. Y., et al. (2023) · Technical Physics Letters · doi:10.1134/s1063785023900686
Yudanov, N. A., Nemirovich, M. A., Andreiko, M. A., Makhnovskiy, D. P., Rodionova, V. V., & Panina, L. V. (2024) · Measurement Techniques · doi:10.1007/s11018-024-02300-6
Miniature Quantum Gradiometer Using 3D Interconnected Atomic Vapor Cells
Zhang, J., & Shang, J. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10917793
“Compared to the quantum gradiometers fabricated with traditional methods, the miniature quantum gradiometers (MQG), empowered by MEMS technology, provide advantages including reduced size, effective cost, and low power consumption [3], [4].”
A Single-Cell Optically Pumped Intrinsic Gradiometer
Zilinski, N., Parameswaran, A. M., Gray, B. L., & Cheung, T. P. L. (2026) · Sensors · doi:10.3390/s26051678 · Cited by 1
“A high CMRR is essential for rejecting environmental noise, and typical values for OPM-based gradiometers using shielding or modulation range from 40 to 60 dB [18–20].”
Wang, Z., Zhang, X., Tang, K., wu, L., Huang, Y. N., Zhang, N., Wang, B., Wang, X. X., Ruan, Y., & Lin, Q. (2026) · Biosensors · doi:10.3390/bios16060316 · Cited by 1
“Recent advances in OPM gradiometry, active noise cancelation, and low-noise shielding have significantly improved the feasibility of field-compatible bio-magnetic sensing [175,176].”
Xu, C., Wu, L., Jiang, J., Dai, Y., Ye, H., Dong, H., & Chen, J. C. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3714614
“Furthermore, such a di ff er-ential configuration can mitigate other noise sources, including laser frequency [23] and intensity fluctuations, temperature drifts, and residual stress e ff ects [19], [24], [25], [26], [27], [28], [29], [30].”
Metadata
- Authors
- Zhang, R., Mhaskar, R., Smith, K., & Prouty, M.
- Affiliations
- Geometrics, Inc ., San Jose, California 95131, USA
- Corresponding author
- Zhang, Rui
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2020-04-06
- Volume
- 116
- Issue
- 14
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W3005689553
- Cited by
- 48
- References
- 24
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 5 · 2023: 8 · 2022: 11 · 2021: 10 · 2020: 4
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Applied Physics Letters (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Strategic Environmental Research and Development Program (MR19-1379)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum optics and atomic interactions
- Keywords
- magnetic gradiometer, cesium vapor magnetometer, Larmor precession, vertical-cavity surface-emitting lasers, magnetic field gradient measurement, unshielded environment, magnetocardiography, unexploded ordnance detection, non-destructive testing, portable sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.