Portable intrinsic gradiometer for ultra-sensitive detection of magnetic gradient in unshielded environment
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We demonstrate a portable all-optical intrinsic scalar magnetic gradiometer composed of miniaturized cesium vapor cells and vertical-cavity surface-emitting lasers (VCSELs). Two cells, with inner dimensions of 5 mm × 5 mm × 5 mm and separated by a baseline of 5 cm, are driven by one VCSEL, and the resulting Larmor precessions are probed by a second VCSEL through optical rotation. The off-resonant linearly polarized probe light interrogates two cells at the same time, and the output of the intrinsic gradiometer is proportional to the magnetic field gradient measured over the given baseline. This intrinsic gradiometer scheme has the advantage of avoiding added noise from combining two scalar magnetometers. We achieve a sensitivity better than 18 fT/cm/√Hz in the gradient measurement. Ultra-sensitive short-baseline magnetic gradiometers can potentially play an important role in many practical applications, such as nondestructive evaluation and unexploded ordnance detection. Another application of the gradiometer is for magnetocardiography (MCG) in an unshielded environment. Real-time MCG signals can be extracted from the raw gradiometer readings. The demonstrated gradiometer greatly simplifies the MCG setup and may lead to a ubiquitous MCG measurement in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“Sensitivities comparable with [2] or even outperforming [3] those of superconducting quantum interference devices (SQUIDs) have been reported with SERF magnetometers.”
BackgroundHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049 · cited 1×
“For example, the discovery of the spin-exchange relaxation-free (SERF) phenomenon at high atomic density and low magnetic field leads to a great improvement in the magnetometer noise performance [1].”
BackgroundUltrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621 · cited 3×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodChip-scale atomic magnetometer
Schwindt, P. D. D., Knappe, S., Shah, V., Hollberg, L., Kitching, J., Liew, L.-A., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1839274 · Cited by 481 · cited 3×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodSubfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364 · cited 1×
“With bigger cells, scalar magnetometers can reach sensitivities of sub-10 fT/√Hz [10] or even sub-fT/√Hz [11].”
BackgroundA laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185 · cited 1×
“With the bandwidth of over 100 Hz, the gradiometer can be used for many applications such as nondestructive evaluation [20], unexploded ordnance (UXO) detection [21] and magnetocardiography (MCG) in an unshielded environment [22, 23, 24, 25].”
MethodChip-scale atomic magnetometer with improved sensitivity by use of the Mx technique
Schwindt, P. D. D., Lindseth, B., Knappe, S., Shah, V., Kitching, J., & Liew, L.-A. (2007) · Applied Physics Letters · doi:10.1063/1.2709532 · Cited by 183 · cited 3×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodAlem, O., Sander, T. H., Mhaskar, R., LeBlanc, J., Eswaran, H., Steinhoff, U., Okada, Y., Kitching, J., Trahms, L., & Knappe, S. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/12/4797 · Cited by 182 · cited 1×
“With the bandwidth of over 100 Hz, the gradiometer can be used for many applications such as nondestructive evaluation [20], unexploded ordnance (UXO) detection [21] and magnetocardiography (MCG) in an unshielded environment [22, 23, 24, 25].”
MethodSelf-citationA low-power, high-sensitivity micromachined optical magnetometer
Mhaskar, R., Knappe, S., & Kitching, J. (2012) · Applied Physics Letters · doi:10.1063/1.4770361 · Cited by 171 · cited 3×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodSelf-citationLee, S.-K., & Romalis, M. V. (2008) · Journal of Applied Physics · doi:10.1063/1.2885711 · Cited by 170
Optical magnetometer array for fetal magnetocardiography
Wyllie, R., Kauer, M., Wakai, R. T., & Walker, T. G. (2012) · Optics Letters · doi:10.1364/ol.37.002247 · Cited by 148 · cited 1×
“With the bandwidth of over 100 Hz, the gradiometer can be used for many applications such as nondestructive evaluation [20], unexploded ordnance (UXO) detection [21] and magnetocardiography (MCG) in an unshielded environment [22, 23, 24, 25].”
MethodLow-noise high-density alkali-metal scalar magnetometer
Smullin, S. J., Savukov, I. M., Vasilakis, G., Ghosh, R. K., & Romalis, M. V. (2009) · Physical Review A · doi:10.1103/physreva.80.033420 · Cited by 139 · cited 1×
“With bigger cells, scalar magnetometers can reach sensitivities of sub-10 fT/√Hz [10] or even sub-fT/√Hz [11].”
BackgroundAn all-optical, high-sensitivity magnetic gradiometer
Affolderbach, C., Stähler, M., Knappe, S. A., & Wynands, R. (2002) · Applied Physics B · doi:10.1007/s00340-002-0959-8 · Cited by 72 · cited 1×
“To overcome this problem, a common solution is to set up a gradiometer system using two or more magnetometers [12, 13, 14, 15].”
MethodMultichannel optical atomic magnetometer operating in unshielded environment
Bevilacqua, G., Biancalana, V., Chessa, P., & Dancheva, Y. V. (2016) · Applied Physics B · doi:10.1007/s00340-016-6375-2 · Cited by 59 · cited 1×
“To overcome this problem, a common solution is to set up a gradiometer system using two or more magnetometers [12, 13, 14, 15].”
MethodMicrofabricated Optically-Pumped Magnetometers for Biomagnetic Applications
Knappe, S., Alem, O., Sheng, D., & Kitching, J. (2016) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/723/1/012055 · Cited by 49 · cited 3×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodDetection of unexploded ordnance (UXO) using marine magnetic gradiometer data
Salem, A., Hamada, T., Asahina, J. K., & Ushijima, K. (2005) · Exploration Geophysics · doi:10.1071/eg05097 · Cited by 48 · cited 1×
“With the bandwidth of over 100 Hz, the gradiometer can be used for many applications such as nondestructive evaluation [20], unexploded ordnance (UXO) detection [21] and magnetocardiography (MCG) in an unshielded environment [22, 23, 24, 25].”
MethodKamada, K., Ito, Y., Ichihara, S., Mizutani, N., & Kobayashi, T. (2015) · Optics Express · doi:10.1364/oe.23.006976 · Cited by 43 · cited 1×
“A similar optical read-out scheme was explored in the SERF regime [18].”
MethodSubpicotesla scalar atomic magnetometer with a microfabricated cell
Zhang, R., Dyer, T., Brockie, N., Parsa, R., & Mhaskar, R. (2019) · Journal of Applied Physics · doi:10.1063/1.5113520 · Cited by 17 · cited 1×
“Highly sensitive SERF magnetometers require a magnetically shielded environment while chip-scale total-field magnetometers have subpar noise performances [5], although a scalar magnetometer with a sensitivity of 100 fT/√Hz has been demonstrated using a MEMS-based cesium vapor cell [9].”
MethodSelf-citationWatanabe, Y., Kang, S. H., Chan, J. W., Morris, J. W., Shaw, T. J., & Clarke, J. L. (2001) · Journal of Applied Physics · doi:10.1063/1.1334637 · Cited by 12
Bai, M., Huang, Y., Zhang, G., Zheng, W., Lin, Q., & Hu, Z. (2019) · Optics Express · doi:10.1364/oe.27.029534 · Cited by 9 · cited 1×
“With the bandwidth of over 100 Hz, the gradiometer can be used for many applications such as nondestructive evaluation [20], unexploded ordnance (UXO) detection [21] and magnetocardiography (MCG) in an unshielded environment [22, 23, 24, 25].”
MethodHighly sensitive miniature scalar optical gradiometer
Zhang, R., Smith, K., & Mhaskar, R. R. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808768 · Cited by 9 · cited 1×
“To overcome this problem, a common solution is to set up a gradiometer system using two or more magnetometers [12, 13, 14, 15].”
MethodSelf-citationA femtotesla quantum-noise-limited pulsed gradiometer at finite fields
Lucivero, V. G., Lee, W., Limes, M. E., Foley, E. L., Kornack, T. W., & Romalis, M. V. (2019) · Quantum Information and Measurement (QIM) · doi:10.1364/qim.2019.t3c.3 · Cited by 8 · cited 1×
“To overcome this problem, a common solution is to set up a gradiometer system using two or more magnetometers [12, 13, 14].”
MethodTotal-field atomic gradiometer for unshielded portable magnetoencephalographyPreprint
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · arXiv (Cornell University) · Cited by 5
Cited by
Sensitive magnetometry in challenging environments
Fu, K. C., Iwata, G. Z., Wickenbrock, A., & Budker, D. (2020) · AVS Quantum Science · doi:10.1116/5.0025186 · Cited by 132
Integrated Optically Pumped Magnetometer for Measurements within Earth’s Magnetic Field
Oelsner, G., IJsselsteijn, R. P. J., Scholtes, T., Krüger, A., Schultze, V., Seyffert, G., Werner, G. R., Jäger, M., Chwala, A., & Stolz, R. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.024034 · Cited by 107
“[21] Rui Zhang, Rahul Mhaskar, Ken Smith, and Mark Prouty, “Portable intrinsic gradiometer for ultra-sensitive detection of magnetic gradient in unshielded environment,” Applied Physics Letters 116, 143501 (2020).”
BackgroundFemtotesla Direct Magnetic Gradiometer Using a Single Multipass Cell
Lucivero, V. G., Lee, W., Dural, N., & Romalis, M. V. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.014004 · Cited by 77
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
SQUIDs for magnetic and electromagnetic methods in mineral exploration
Stolz, R., Schiffler, M., Becken, M., Thiede, A., Schneider, M., Chubak, G., Marsden, P., Bergshjorth, A. B., Schaefer, M. O., & Terblanche, O. (2022) · Mineral Economics · doi:10.1007/s13563-022-00333-3 · Cited by 65
Metadata
- Authors
- Zhang, R., Mhaskar, R., Smith, K., & Prouty, M.
- Affiliations
- Geometrics, Inc ., San Jose, California 95131, USA
- Corresponding author
- Zhang, Rui
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2020-04-06
- Volume
- 116
- Issue
- 14
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W3005689553
- Cited by
- 48
- References
- 24
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 5 · 2023: 8 · 2022: 11 · 2021: 10 · 2020: 4
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Applied Physics Letters (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Strategic Environmental Research and Development Program (MR19-1379)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum optics and atomic interactions
- Keywords
- magnetic gradiometer, cesium vapor magnetometer, Larmor precession, vertical-cavity surface-emitting lasers, magnetic field gradient measurement, unshielded environment, magnetocardiography, unexploded ordnance detection, non-destructive testing, portable sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.