Design, calibration and calculation for flow-through respirometry systems
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Flow-through respirometry systems that measure oxygen consumption (VO2), carbon dioxide production (VCO2) and evaporative water loss (EWL) require the accurate calibration of the flow meter and three separate analysers (O2, CO2 and H2O vapour). Correct measurement of VO2, VCO2 and EWL depends on the incurrent air flow (VI) and its condition (e.g. dry, CO2-free), and the excurrent air flow (VE) and its condition (e.g. dry, CO2-free), which can differ in different parts of the excurrent circuit. Usually either VI or VE is measured and the other is calculated from the gas composition. I describe here a procedure for precise calibration of CO2 and H2O analysers in a flow-through respirometry system by reference to a calibrated O2 analyser, using a small gas flame. Generic equations are derived for calculation of VO2, VO2 and EWL with a variety of configurations for a flow-through respirometry system. Procedures for selection of data from continuous records of VO2, VCO2 and EWL for calculation of minimal (basal or standard) values are briefly described. Finally, the importance of the correct order of data treatment prior to calculation is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Locally Weighted Regression and Smoothing Scatterplots
Cleveland, W. S. (1979) · Journal of the American Statistical Association · doi:10.1080/01621459.1979.10481038 · Cited by 11,594
One-step N2-dilution technique for calibrating open-circuit VO2 measuring systems
Fedak, M. A., Rome, L., & Seeherman, H. J. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.3.772 · Cited by 337
Withers, P. C., Thompson, G. G., & Seymour, R. S. (2000) · Australian Journal of Zoology · doi:10.1071/zo99073 · Cited by 74
Self-citation
Cited by
Energy metabolism and animal personality
Careau, V., Thomas, D., Humphries, M. M., & Réale, D. (2008) · Oikos · doi:10.1111/j.0030-1299.2008.16513.x · Cited by 888
WILSON, R. P., WHITE, C. R., QUINTANA, F., HALSEY, L. G., LIEBSCH, N., MARTIN, G. R., & BUTLER, P. J. (2006) · Journal of Animal Ecology · doi:10.1111/j.1365-2656.2006.01127.x · Cited by 797
“oxygen consumption (VO , ml min-') and carbon dioxide production (Vco, ml min-') were recorded using standard positive pressure open-flow respirometry (Withers 2001).”
MethodLighton, J. R. B. (2008) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195310610.001.0001 · Cited by 739
Jung, C. M., Melanson, E. L., Frydendall, E. J., Perreault, L., Eckel, R. H., & Wright, K. P. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2010.197517 · Cited by 318
Oxygen limitation and thermal tolerance in two terrestrial arthropod species
Stevens, M. M., Jackson, S., Bester, S. A., Terblanche, J. S., & Chown, S. L. (2010) · Journal of Experimental Biology · doi:10.1242/jeb.040170 · Cited by 115
“The extent of this affinity can be investigated by estimating the washout of CO2 from both the cuvette and the scrubber column (see Withers, 2001; White et al., 2006).”
Background
Metadata
- Authors
- Withers, P. C.
- Venue
- Australian Journal of Zoology
- Publisher
- CSIRO Publishing
- Published
- 2001-09-26
- Volume
- 49
- Issue
- 4
- Pages
- 445-461
- ISSN
- 0004-959X (ISSN-L)
- 1446-5698
- OpenAlex
- W1686762661
- Cited by
- 238
- References
- 3
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design, calibration and calculation for flow-through respirometry systems. https://app.cochat.ai/papers/10.1071/zo00057
- The paper
- Withers, P. C. (2001). Design, calibration and calculation for flow-through respirometry systems. Australian Journal of Zoology. https://doi.org/10.1071/zo00057
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.