The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Visualization of antitumor treatment by means of fluorescence molecular tomography with an annexin V–Cy5.5 conjugate
Open accessAbstract
In vivo imaging of treatment responses at the molecular level could have a significant impact on the speed of drug discovery and ultimately lead to personalized medicine. Strong interest has been shown in developing quantitative fluorescence-based technologies with good molecular specificity and sensitivity for noninvasive 3D imaging through tissues and whole animals. We show herein that tumor response to chemotherapy can be accurately resolved by fluorescence molecular tomography (FMT) with a phosphatidylserine-sensing fluorescent probe based on modified annexins. We observed at least a 10-fold increase of fluorochrome concentration in cyclophosphamide-sensitive tumors and a 7-fold increase of resistant tumors compared with control studies. FMT is an optical imaging technique developed to overcome limitations of commonly used planar illumination methods and demonstrates higher quantification accuracy validated by histology. It is further shown that a 3-fold variation in background absorption heterogeneity may yield 100% errors in planar imaging but only 20% error in FMT, thus confirming tomographic imaging as a preferred tool for quantitative investigations of fluorescent probes in tissues. Tomographic approaches are found essential for small-animal optical imaging and are potentially well suited for clinical drug development and monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Apoptosis in the Pathogenesis and Treatment of Disease
Thompson, C. B. (1995) · Science · doi:10.1126/science.7878464 · Cited by 6,524
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Integrin αvβ3 antagonists promote tumor regression by inducing apoptosis of angiogenic blood vessels
Brooks, P. C., Montgomery, A. M. P., Rosenfeld, M., Reisfeld, R. A., Hu, T., Klier, G., & Cheresh, D. A. (1994) · Cell · doi:10.1016/0092-8674(94)90007-8 · Cited by 2,262
Molecular imaging in living subjects: seeing fundamental biological processes in a new light
Massoud, T. F., & Gambhir, S. S. (2003) · Genes & Development · doi:10.1101/gad.1047403 · Cited by 2,216
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Self-citationNtziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982
Self-citationFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
Self-citationSpectroscopy and Imaging with Diffusing Light
Yodh, A., & Chance, B. (1995) · Physics Today · doi:10.1063/1.881445 · Cited by 800
Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Self-citationIn vivo molecular target assessment of matrix metalloproteinase inhibition
Bremer, C., Tung, C.-H., & Weissleder, R. (2001) · Nature Medicine · doi:10.1038/89126 · Cited by 726
Self-citation
Cited by
Imaging in the era of molecular oncology
Weissleder, R., & Pittet, M. J. (2008) · Nature · doi:10.1038/nature06917 · Cited by 2,364
Self-citationLooking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
Self-citationMolecular imaging in drug development
Willmann, J. K., van Bruggen, N., Dinkelborg, L. M., & Gambhir, S. S. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2290 · Cited by 1,171
Nanotechnology applications in cancer
Nie, S., Xing, Y., Kim, G. J., & Simons, J. W. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.152025 · Cited by 952
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Sharma, P., Brown, S., Walter, G., Santra, S., & Moudgil, B. (2006) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2006.05.026 · Cited by 755
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Self-citationMammalian Expression of Infrared Fluorescent Proteins Engineered from a Bacterial Phytochrome
Shu, X., Royant, A., Lin, M. Z., Aguilera, T. A., Lev-Ram, V., Steinbach, P. A., & Tsien, R. Y. (2009) · Science · doi:10.1126/science.1168683 · Cited by 675
Bhaskar, S., Tian, F., Stoeger, T., Kreyling, W., de la Fuente, J. M., Grazú, V., Borm, P., Estrada, G., Ntziachristos, V., & Razansky, D. (2010) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-7-3 · Cited by 495
Self-citationBlocking of the PD‐1/PD‐L1 Interaction by a D‐Peptide Antagonist for Cancer Immunotherapy
Chang, H., Liu, B., Qi, Y., Zhou, Y., Chen, Y., Pan, K., Li, W., Zhou, X., Ma, W., Fu, C., et al. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201506225 · Cited by 397
Tutorial on diffuse light transport
Jacques, S. L., & Pogue, B. W. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2967535 · Cited by 354
Kundu, K., Knight, S. F., Willett, N., Lee, S., Taylor, W. R., & Murthy, N. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200804851 · Cited by 339
Fluorescent Biomembrane Probe for Ratiometric Detection of Apoptosis
Shynkar, V. V., Klymchenko, A. S., Kunzelmann, C., Duportail, G., Muller, C. D., Demchenko, A. P., Freyssinet, J.-M., & Mely, Y. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068008h · Cited by 335
Optically-controlled bacterial metabolite for cancer therapy
Zheng, D.-W., Chen, Y., Li, Z.-H., Xu, L., Li, C.-X., Li, B., Fan, J.-X., Cheng, S.-X., & Zhang, X.-Z. (2018) · Nature Communications · doi:10.1038/s41467-018-03233-9 · Cited by 324
Noninvasive optical imaging of apoptosis by caspase-targeted activity-based probes
Edgington, L. E., Berger, A. B., Blum, G., Albrow, V. E., Paulick, M. G., Lineberry, N., & Bogyo, M. (2009) · Nature Medicine · doi:10.1038/nm.1938 · Cited by 276
Engineered nanoparticles for biomolecular imaging
Mahmoudi, M., Serpooshan, V., & Laurent, S. (2011) · Nanoscale · doi:10.1039/c1nr10326a · Cited by 262
Advances in imaging mouse tumour models in vivo
Lyons, S. K. (2005) · The Journal of Pathology · doi:10.1002/path.1697 · Cited by 174
Yang, Z., Zheng, S., Harrison, W. J., Harder, J., Wen, X., Gelovani, J. G., Qiao, A., & Li, C. (2007) · Biomacromolecules · doi:10.1021/bm7005399 · Cited by 130
Metadata
- Authors
- Ntziachristos, V., Schellenberger, E. A., Ripoll, J., Yessayan, D., Graves, E., Bogdanov, A., Josephson, L., & Weissleder, R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-08-10
- Volume
- 101
- Issue
- 33
- Pages
- 12294-12299
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2123021242
- Cited by
- 348
- References
- 23
- FWCI
- 24.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.