The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Nanometer-localized multiple single-molecule fluorescence microscopy
Open accessAbstract
Fitting the image of a single molecule to the point spread function of an optical system greatly improves the precision with which single molecules can be located. Centroid localization with nanometer precision has been achieved when a sufficient number of photons are collected. However, if multiple single molecules reside within a diffraction-limited spot, this localization approach does not work. This paper demonstrates nanometer-localized multiple single-molecule (NALMS) fluorescence microscopy by using both centroid localization and photobleaching of the single fluorophores. Short duplex DNA strands are used as nanoscale “rulers” to validate the NALMS microscopy approach. Nanometer accuracy is demonstrated for two to five single molecules within a diffraction-limited area. NALMS microscopy will greatly facilitate single-molecule study of biological systems because it covers the gap between fluorescence resonance energy transfer-based (<10 nm) and diffraction-limited microscopy (>100 nm) measurements of the distance between two fluorophores. Application of NALMS microscopy to DNA mapping with <10-nm (i.e., 30-base) resolution is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Log-normal distributions across the sciences: keys and clues
LIMPERT, E., STAHEL, W. A., & ABBT, M. (2001) · BioScience · doi:10.1641/0006-3568(2001)051[0341:lndats]2.0.co;2 · Cited by 2,621
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization
Yildiz, A., Forkey, J. N., McKinney, S. A., Ha, T., Goldman, Y. E., & Selvin, P. R. (2003) · Science · doi:10.1126/science.1084398 · Cited by 1,837
Yildiz, A., Tomishige, M., Vale, R. D., & Selvin, P. R. (2004) · Science · doi:10.1126/science.1093753 · Cited by 965
Quantitative Comparison of Algorithms for Tracking Single Fluorescent Particles
Cheezum, M. K., Walker, W. F., & Guilford, W. H. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75884-5 · Cited by 896
Tracking kinesin-driven movements with nanometre-scale precision
Gelles, J., Schnapp, B. J., & Sheetz, M. P. (1988) · Nature · doi:10.1038/331450a0 · Cited by 819
Single-Molecule Fluorescence Resonance Energy Transfer
Ha, T. (2001) · Methods · doi:10.1006/meth.2001.1217 · Cited by 626
Dynamic Molecular Combing: Stretching the Whole Human Genome for High-Resolution Studies
Michalet, X., Ekong, R., Fougerousse, F., Rousseaux, S., Schurra, C., Hornigold, N., Slegtenhorst, M. V., Wolfe, J., Povey, S., Beckmann, J. S., et al. (1997) · Science · doi:10.1126/science.277.5331.1518 · Cited by 611
Cited by
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Diffusional trapping of GluR1 AMPA receptors by input-specific synaptic activity
Ehlers, M. D., Heine, M., Groc, L., Lee, M.-C., & Choquet, D. (2007) · Neuron · doi:10.1016/j.neuron.2007.04.010 · Cited by 300
Metadata
- Authors
- Qu, X., Wu, D., Mets, L., & Scherer, N. F.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-07-26
- Volume
- 101
- Issue
- 31
- Pages
- 11298-11303
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2148283489
- Cited by
- 304
- References
- 24
- FWCI
- 9.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanometer-localized multiple single-molecule fluorescence microscopy. https://app.cochat.ai/papers/10.1073/pnas.0402155101
- The paper
- Qu, X., Wu, D., Mets, L., & Scherer, N. F. (2004). Nanometer-localized multiple single-molecule fluorescence microscopy. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0402155101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.