Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 304

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Nanometer-localized multiple single-molecule fluorescence microscopy

Open access
Qu, Xiaohui, Wu, David, Mets, Laurens, Scherer, Norbert F.·2004·Proceedings of the National Academy of Sciences

Abstract

Fitting the image of a single molecule to the point spread function of an optical system greatly improves the precision with which single molecules can be located. Centroid localization with nanometer precision has been achieved when a sufficient number of photons are collected. However, if multiple single molecules reside within a diffraction-limited spot, this localization approach does not work. This paper demonstrates nanometer-localized multiple single-molecule (NALMS) fluorescence microscopy by using both centroid localization and photobleaching of the single fluorophores. Short duplex DNA strands are used as nanoscale “rulers” to validate the NALMS microscopy approach. Nanometer accuracy is demonstrated for two to five single molecules within a diffraction-limited area. NALMS microscopy will greatly facilitate single-molecule study of biological systems because it covers the gap between fluorescence resonance energy transfer-based (<10 nm) and diffraction-limited microscopy (>100 nm) measurements of the distance between two fluorophores. Application of NALMS microscopy to DNA mapping with <10-nm (i.e., 30-base) resolution is demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.0402155101

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 304

Metadata

Authors
Qu, X., Wu, D., Mets, L., & Scherer, N. F.
Venue
Proceedings of the National Academy of Sciences
Published
2004-07-26
Volume
101
Issue
31
Pages
11298-11303
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2148283489
Cited by
304
References
24
FWCI
9.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nanometer-localized multiple single-molecule fluorescence microscopy. https://app.cochat.ai/papers/10.1073/pnas.0402155101
The paper
Qu, X., Wu, D., Mets, L., & Scherer, N. F. (2004). Nanometer-localized multiple single-molecule fluorescence microscopy. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0402155101

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.