CoChat

Selective fluorescent imaging of superoxide in vivo using ethidium-based probes

Open access

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

The putative oxidation of hydroethidine (HE) has become a widely used fluorescent assay for the detection of superoxide in cultured cells. By covalently joining HE to a hexyl triphenylphosphonium cation (Mito-HE), the HE moiety can be targeted to mitochondria. However, the specificity of HE and Mito-HE for superoxide in vivo is limited by autooxidation as well as by nonsuperoxide-dependent cellular processes that can oxidize HE probes to ethidium (Etd). Recently, superoxide was shown to react with HE to generate 2-hydroxyethidium [Zhao, H., Kalivendi, S., Zhang, H., Joseph, J., Nithipatikom, K., Vasquez-Vivar, J. & Kalyanaraman, B. (2003) Free Radic. Biol. Med. 34, 1359–1368]. However, 2-hydroxyethidium is difficult to distinguish from Etd by conventional fluorescence techniques exciting at 510 nm. While investigating the oxidation of Mito-HE by superoxide, we found that the superoxide product of both HE and Mito-HE could be selectively excited at 396 nm with minimal interference from other nonspecific oxidation products. The oxidation of Mito-HE monitored at 396 nm by antimycin-stimulated mitochondria was 30% slower than at 510 nm, indicating that superoxide production may be overestimated at 510 nm by even a traditional superoxide-stimulating mitochondrial inhibitor. The rate-limiting step for oxidation by superoxide was 4 × 10 6 M −1 ·s −1 , which is proposed to involve the formation of a radical from Mito-HE. The rapid reaction with a second superoxide anion through radical–radical coupling may explain how Mito-HE and HE can compete for superoxide in vivo with intracellular superoxide dismutases. Monitoring oxidation at both 396 and 510 nm of excitation wavelengths can facilitate the more selective detection of superoxide in vivo .

Overview

Integrity signals

Registry

Crossref · 10.1073/pnas.0601945103

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. PM Gallop, MA Paz, E Henson, SA Latt BioTechniques 1, 32–36 (1984).

Cited by

See all 792

Metadata

Authors
Robinson, K. M., Janes, M. S., Pehar, M., Monette, J. S., Ross, M. F., Hagen, T. M., Murphy, M. P., & Beckman, J. S.
Affiliations
  • Oregon State University (US)
  • Instituto de Investigaciones Biológicas Clemente Estable (UY)
  • MRC Mitochondrial Biology Unit (GB)
Venue
Proceedings of the National Academy of Sciences
Published
2006-10-10
Volume
103
Issue
41
Pages
15038-15043
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2098227836
Cited by
777
References
37
Citations by year
2026: 30 · 2025: 27 · 2024: 38 · 2023: 21 · 2022: 30 · 2021: 37 · 2020: 43 · 2019: 39 · 2018: 38 · 2017: 51 · 2016: 51 · 2015: 44 · 2014: 48 · 2013: 59 · 2012: 35
FWCI
14.94
Type
journal article
Language
en
Open access
Locations
  • Proceedings of the National Academy of Sciences (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Oregon State University
  • U.S. Public Health Service (PAT002034-01)
  • National Institute on Aging (AG17141A, R01AG017141)
  • Fogarty International Center (R03TW006482, TW006482-02)
  • National Institute of Environmental Health Sciences (ES-00040, P01ES000040, ES-00240)
  • National Center for Complementary and Integrative Health (P01AT002034, AT002034-02)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Redox biology and oxidative stress
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
Keywords
superoxide detection, hydroethidine, ethidium, fluorescent probes, mitochondrial superoxide, autooxidation, antimycin A, superoxide dismutase, radical-radical coupling, in vivo imaging
MeSH terms
Animals, Animals, Newborn, Cells, Cultured, Chromatography, High Pressure Liquid, Ethidium, Fluorescent Dyes, Mitochondria, Phenanthridines, Spectrometry, Fluorescence, Superoxides, Rats, Sprague-Dawley, Microscopy, Confocal, Spectrometry, Mass, Electrospray Ionization, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.