Differential patterning of cGMP in vascular smooth muscle cells revealed by single GFP-linked biosensors
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Here, we report the design of unprecedented, non-FRET based cGMP-biosensors, named FlincGs, to assess the dynamics of nitric oxide (NO) and atrial natriuretic peptide (ANP) induced synthesis of intracellular cGMP, [cGMP] i . Regulatory fragments of PKG I α, PKG I β, and an N-terminal deletion mutant of PKG I α were fused to circular permutated EGFP to generate α-, β-, and δ-FlincG, with high dynamic ranges and apparent K D,cGMP values of 35 nM, 1.1 μM, and 170 nM, respectively. All indicators displayed significant selectivity for cGMP over cAMP, and 1.5- to 2.1-fold increases in fluorescence intensity at 510 nm when excited at 480 nm. Surprisingly, FlincGs displayed an additional excitation peak at 410 nm. δ-FlincG permitted ratiometric (480/410 nm) measurements, with a cGMP-specific 3.5-fold ratio change. In addition, δ-FlincG presented cGMP association and dissociation kinetics sufficiently fast to monitor rapid changes of [cGMP] i in intact cells. In unpassaged, adenoviral transfected vascular smooth muscle (VSM) cells, δ-FlincG had an EC 50,cGMP of 150 nM, and revealed transient global cGMP elevations to sustained physiological NO (EC 50,DEA/NO = 4 nM), and the decay phase depended on the activity of PDE-5. In contrast, ANP elicited sustained submembrane elevations in [cGMP] i , which were converted to global cGMP elevations by inhibition of PDE-5 by sildenafil. These results indicate that FlincG is an innovative tool to elucidate the dynamics of a central biological signal, cGMP, and that NO and natriuretic peptides induce distinct cGMP patterning under the regulation of PDE-5, and therefore likely differentially engage cGMP targets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new generation of Ca2+ indicators with greatly improved fluorescence properties.
Grynkiewicz, G., Poenie, M., & Tsien, R. Y. (1985) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)83641-4 · Cited by 21,607
Polazzi, E., Mengoni, I., Caprini, M., Peña-Altamira, E., Kurtys, E., & Monti, B. (2013) · Neurosignals · doi:10.1159/000337115 · Cited by 8,994
International Union of Pharmacology: Approaches to the Nomenclature of Voltage-Gated Ion Channels
Catterall, W. A., Chandy, K. G., Clapham, D. E., Gutman, G. A., Hofmann, F., Harmar, A. J., Abernethy, D. R., & Spedding, M. (2003) · Pharmacological Reviews · doi:10.1124/pr.55.4.5 · Cited by 7,126
A high signal-to-noise Ca2+ probe composed of a single green fluorescent protein
Nakai, J., Ohkura, M., & Imoto, K. (2001) · Nature Biotechnology · doi:10.1038/84397 · Cited by 1,616
Conti, M., & Beavo, J. (2007) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.76.060305.150444 · Cited by 1,183 · cited 2×
“guanylyl cyclase by 1H-[1,2,4]oxadiazolo[4,3-a]quinoxalin-1-one.”
BackgroundGarthwaite, J., Southam, E., Boulton, C. L., Nielsen, E. B., Schmidt, K., & Mayer, B. (1995) · Molecular Pharmacology · doi:10.1016/s0026-895x(25)10233-2 · Cited by 1,101
Reducing the Environmental Sensitivity of Yellow Fluorescent Protein
Griesbeck, O., Baird, G. S., Campbell, R. E., Zacharias, D. A., & Tsien, R. Y. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m102815200 · Cited by 1,023
Circular permutation and receptor insertion within green fluorescent proteins
Baird, G. S., Zacharias, D. A., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.20.11241 · Cited by 961
Robertson, B. E., Schubert, R., Hescheler, J., & Nelson, M. T. (1993) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1993.265.1.c299 · Cited by 618
Self-citationWinquist, R. J., Faison, E. P., Waldman, S. A., Schwartz, K., Murad, F., & Rapoport, R. M. (1984) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.81.23.7661 · Cited by 497
Cited by
Concepts of neural nitric oxide‐mediated transmission
Garthwaite, J. (2008) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2008.06285.x · Cited by 807
Imaging cytosolic NADH-NAD(+) redox state with a genetically encoded fluorescent biosensor
Hung, Y. P., Albeck, J. G., Tantama, M., & Yellen, G. (2011) · Cell Metabolism · doi:10.1016/j.cmet.2011.08.012 · Cited by 509
“With this strategy, fluorescent biosensors have been engineered to report calcium, hydrogen peroxide, cyclic 30,50-guanosine monophosphate (cGMP), and ATP:ADP ratio (Nagai et al., 2001; Belousov et al., 2006; Nausch et al., 2008; Berg et al., 2009).”
Greenwald, E. C., Mehta, S., & Zhang, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00333 · Cited by 495
Cyclic GMP signaling in cardiovascular pathophysiology and therapeutics
Tsai, E. J., & Kass, D. A. (2009) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2009.02.009 · Cited by 420
What is the real physiological NO concentration in vivo?
Hall, C. N., & Garthwaite, J. (2009) · Nitric Oxide · doi:10.1016/j.niox.2009.07.002 · Cited by 378
“The recent engineering of cGMP biosensors with improved kinetics [42,43] should provide the means for obtaining complementary information using endogenous GCs as the NO detectors and amplifiers, potentially allowing quantifiable responses to NO in the low nM range and below.”
BackgroundPhosphodiesterase 9A controls nitric-oxide-independent cGMP and hypertrophic heart disease
Lee, D. I., Zhu, G., Sasaki, T., Cho, G.-S., Hamdani, N., Holewinski, R., Jo, S.-H., Danner, T., Zhang, M., Rainer, P. P., et al. (2015) · Nature · doi:10.1038/nature14332 · Cited by 353
Self-citationGenetically Encodable Fluorescent Biosensors for Tracking Signaling Dynamics in Living Cells
Newman, R. H., Fosbrink, M. D., & Zhang, J. (2011) · Chemical Reviews · doi:10.1021/cr100002u · Cited by 353
Lohse, M. J., Nuber, S., & Hoffmann, C. (2012) · Pharmacological Reviews · doi:10.1124/pr.110.004309 · Cited by 307
Connecting the Chemical and Biological Properties of Nitric Oxide
Toledo, J. C., & Augusto, O. (2012) · Chemical Research in Toxicology · doi:10.1021/tx300042g · Cited by 286
Castrop, H., Höcherl, K., Kurtz, A., Schweda, F., Todorov, V., & Wagner, C. (2010) · Physiological Reviews · doi:10.1152/physrev.00011.2009 · Cited by 269
Structure- and mechanism-guided design of single fluorescent protein-based biosensors
Nasu, Y., Shen, Y., Kramer, L., & Campbell, R. E. (2021) · Nature Chemical Biology · doi:10.1038/s41589-020-00718-x · Cited by 225
Cyclic nucleotide-dependent relaxation pathways in vascular smooth muscle
Morgado, M., Cairrão, E., Santos-Silva, A. J., & Verde, I. (2012) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-011-0815-2 · Cited by 196
Structural Basis for Calcium Sensing by GCaMP2
Wang, Q., Shui, B., Kotlikoff, M. I., & Sondermann, H. (2008) · Structure · doi:10.1016/j.str.2008.10.008 · Cited by 170
“Genetically encoded Ca indicators (GECIs) enable the monitoring of intracellular signaling events in defined cell lineages within complex multicellular tissues, without disrupting cell-cell contacts or permeabilizing cell membranes (Ledoux et al., 2008; Mao et al., 2008; Miyawaki et al., 1997, 1999; Nausch et al., 200…”
BackgroundGarthwaite, J. (2010) · Molecular and Cellular Biochemistry · doi:10.1007/s11010-009-0318-8 · Cited by 102
“fluorescent methods for imaging cellular cGMP in physiological concentrations and in real time [94–96] offers a”
BackgroundSubcellular second messenger networks drive distinct repellent-induced axon behaviors
Baudet, S., Zagar, Y., Roche, F., Gomez-Bravo, C., Couvet, S., Bécret, J., Belle, M., Vougny, J., Uthayasuthan, S., Ros, O., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-39516-z · Cited by 13
Metadata
- Authors
- Nausch, L. W. M., Ledoux, J., Bonev, A. D., Nelson, M. T., & Dostmann, W. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-01-08
- Volume
- 105
- Issue
- 1
- Pages
- 365-370
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1986217842
- Cited by
- 164
- References
- 46
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.