The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Multitarget magnetic activated cell sorter
Open accessAbstract
Magnetic selection allows high-throughput sorting of target cells based on surface markers, and it is extensively used in biotechnology for a wide range of applications from in vitro diagnostics to cell-based therapies. However, existing methods can only perform separation based on a single parameter (i.e., the presence or absence of magnetization), and therefore, the simultaneous sorting of multiple targets at high levels of purity, recovery, and throughput remains a challenge. In this work, we present an alternative system, the multitarget magnetic activated cell sorter (MT-MACS), which makes use of microfluidics technology to achieve simultaneous spatially-addressable sorting of multiple target cell types in a continuous-flow manner. We used the MT-MACS device to purify 2 types of target cells, which had been labeled via target-specific affinity reagents with 2 different magnetic tags with distinct saturation magnetization and size. The device was engineered so that the combined effects of the hydrodynamic force produced from the laminar flow and the magnetophoretic force produced from patterned ferromagnetic structures within the microchannel result in the selective purification of the differentially labeled target cells into multiple independent outlets. We demonstrate here the capability to simultaneously sort multiple magnetic tags with >90% purity and >5,000-fold enrichment and multiple bacterial cell types with >90% purity and >500-fold enrichment at a throughput of 10 9 cells per hour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shapiro, H. M. (2003) · Wiley eBooks · doi:10.1002/0471722731 · Cited by 2,671
Bone-Marrow Transplantation: (First of Two Parts)
Thomas, E. D., Storb, R., Clift, R. A., Fefer, A., Johnson, F. L., Neiman, P. E., Lerner, K. G., Glucksberg, H., & Buckner, C. D. (1975) · New England Journal of Medicine · doi:10.1056/nejm197504172921605 · Cited by 1,693
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Chemical Amplification: Continuous-Flow PCR on a Chip
Kopp, M. U., Mello, A. J. D., & Manz, A. (1998) · Science · doi:10.1126/science.280.5366.1046 · Cited by 1,212
Bone-Marrow Transplantation: (Second of Two Parts)
Thomas, E. D., Storb, R., Clift, R. A., Fefer, A., Johnson, F. L., Neiman, P. E., Lerner, K. G., Glucksberg, H., & Buckner, C. D. (1975) · New England Journal of Medicine · doi:10.1056/nejm197504242921706 · Cited by 1,182
A biosensor based on magnetoresistance technology
Baselt, D. R., Lee, G. U., Natesan, M., Metzger, S. W., Sheehan, P. E., & Colton, R. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00037-2 · Cited by 823
Yamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Use of magnetic techniques for the isolation of cells
Šafařı́k, I., & Šafařı́ková, M. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00338-7 · Cited by 617
An improved immunomagnetic procedure for the isolation of highly purified human blood eosinophils
Hansel, T. T., De Vries, I. J. M., Iff, T., Rihs, S., Wandzilak, M., Betz, S., Blaser, K., & Walker, C. (1991) · Journal of Immunological Methods · doi:10.1016/0022-1759(91)90315-7 · Cited by 601
Allogeneic Bone‐Marrow Transplantation
Storb, R., & Thomas, E. D. (1983) · Immunological Reviews · doi:10.1111/j.1600-065x.1983.tb01069.x · Cited by 587
On-Chip Free-Flow Magnetophoresis: Continuous Flow Separation of Magnetic Particles and Agglomerates
Pamme, N., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac049183o · Cited by 475
Continuous microfluidic immunomagnetic cell separation
Inglis, D. W., Riehn, R., Austin, R. H., & Sturm, J. C. (2004) · Applied Physics Letters · doi:10.1063/1.1823015 · Cited by 353
Selection of ventricular‐like cardiomyocytes from ES cells in vitro
MÜller, M., Fleischmann, B. K., Selbert, S., Ji, G. J., Endl, E., Middeler, G., MÜller, O. J., Schlenke, P., Frese, S., Wobus, A. M., et al. (2000) · The FASEB Journal · doi:10.1096/fj.00-0002com · Cited by 292
Patterson, B. K., Till, M., Otto, P., Goolsby, C., Furtado, M. R., McBride, L. J., & Wolinsky, S. M. (1993) · Science · doi:10.1126/science.8493534 · Cited by 264
Applications of cell sorting in biotechnology
Mattanovich, D., & Borth, N. (2006) · Microbial Cell Factories · doi:10.1186/1475-2859-5-12 · Cited by 165
Rapid isolation of high-affinity protein binding peptides using bacterial display
Bessette, P. H., Rice, J. J., & Daugherty, P. S. (2004) · Protein Engineering Design and Selection · doi:10.1093/protein/gzh084 · Cited by 155
Continuous magnetophoretic separation of blood cells in microdevice format
Han, K.-H., & Frazier, A. B. (2004) · Journal of Applied Physics · doi:10.1063/1.1803628 · Cited by 151
Smistrup, K., Hansen, O. P., Bruus, H., et al. (2005) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2005.01.079 · Cited by 146
Mena, M. A., Treynor, T. P., Mayo, S. L., & Daugherty, P. S. (2006) · Nature Biotechnology · doi:10.1038/nbt1264 · Cited by 140
Flow Through, Immunomagnetic Cell Separation
Chalmers, J. J., Zborowski, M., Sun, L., et al. (1998) · Biotechnology Progress · doi:10.1021/bp970140l · Cited by 132
Pamme, N., Eijkel, J. C. T., & Manz, A. (2006) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.04.008 · Cited by 125
Rice, J. J., Schohn, A., Bessette, P. H., Boulware, K. T., & Daugherty, P. S. (2006) · Protein Science · doi:10.1110/ps.051897806 · Cited by 117
Pavlovic, E., Lai, R. Y., Wu, T., Ferguson, B. S., Sun, R., Plaxco, K. W., & Soh, H. T. (2008) · Langmuir · doi:10.1021/la702681c · Cited by 80
Self-citationOn-chip separation of magnetic particles with different magnetophoretic mobilities
Liu, C., Lagae, L., Wirix-Speetjens, R., & Borghs, G. (2007) · Journal of Applied Physics · doi:10.1063/1.2423137 · Cited by 55
Cited by
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Particle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Magnetic responsive polymer composite materials
Thévenot, J., Oliveira, H., Sandre, O., & Lecommandoux, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60058k · Cited by 633
Metadata
- Authors
- Adams, J. D., Kim, U., & Soh, H. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-11-25
- Volume
- 105
- Issue
- 47
- Pages
- 18165-18170
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2071747626
- Cited by
- 390
- References
- 25
- FWCI
- 12.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.