Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 288

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Multiplex protein assays based on real-time magnetic nanotag sensing

Open access
Osterfeld, Sebastian J., Yu, Heng, Gaster, Richard S., Caramuta, Stefano, Xu, Liang, Han, Shu-Jen, Hall, Drew A., Wilson, Robert J., Sun, Shouheng, White, Robert L., Davis, Ronald W., Pourmand, Nader, Wang, Shan X.·2008·Proceedings of the National Academy of Sciences

Abstract

Magnetic nanotags (MNTs) are a promising alternative to fluorescent labels in biomolecular detection assays, because minute quantities of MNTs can be detected with inexpensive giant magnetoresistive (GMR) sensors, such as spin valve (SV) sensors. However, translating this promise into easy to use and multilplexed protein assays, which are highly sought after in molecular diagnostics such as cancer diagnosis and treatment monitoring, has been challenging. Here, we demonstrate multiplex protein detection of potential cancer markers at subpicomolar concentration levels and with a dynamic range of more than four decades. With the addition of nanotag amplification, the analytic sensitivity extends into the low fM concentration range. The multianalyte ability, sensitivity, scalability, and ease of use of the MNT-based protein assay technology make it a strong contender for versatile and portable molecular diagnostics in both research and clinical settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.0810822105

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 288

Metadata

Authors
Osterfeld, S. J., Yu, H., Gaster, R. S., Caramuta, S., Xu, L., Han, S.-J., Hall, D. A., Wilson, R. J., Sun, S., White, R. L., Davis, R. W., Pourmand, N., & Wang, S. X.
Venue
Proceedings of the National Academy of Sciences
Published
2008-12-30
Volume
105
Issue
52
Pages
20637-20640
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2096143567
Cited by
288
References
17
FWCI
7.69
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiplex protein assays based on real-time magnetic nanotag sensing. https://app.cochat.ai/papers/10.1073/pnas.0810822105
The paper
Osterfeld, S. J., Yu, H., Gaster, R. S., Caramuta, S., Xu, L., Han, S.-J., Hall, D. A., Wilson, R. J., Sun, S., White, R. L., Davis, R. W., Pourmand, N., & Wang, S. X. (2008). Multiplex protein assays based on real-time magnetic nanotag sensing. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0810822105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.