CoChat

Isolation and mutational analysis of circulating tumor cells from lung cancer patients with magnetic sifters and biochips

Open access

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

Detection and characterization of circulating tumor cells (CTCs) may reveal insights into the diagnosis and treatment of malignant disease. Technologies for isolating CTCs developed thus far suffer from one or more limitations, such as low throughput, inability to release captured cells, and reliance on expensive instrumentation for enrichment or subsequent characterization. We report a continuing development of a magnetic separation device, the magnetic sifter, which is a miniature microfluidic chip with a dense array of magnetic pores. It offers high efficiency capture of tumor cells, labeled with magnetic nanoparticles, from whole blood with high throughput and efficient release of captured cells. For subsequent characterization of CTCs, an assay, using a protein chip with giant magnetoresistive nanosensors, has been implemented for mutational analysis of CTCs enriched with the magnetic sifter. The use of these magnetic technologies, which are separate devices, may lead the way to routine preparation and characterization of "liquid biopsies" from cancer patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3lc50580d

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 41 references

Cited by

See all 165

Metadata

Authors
Earhart, C. M., Hughes, C. E., Gaster, R. S., Ooi, C. C., Wilson, R. J., Zhou, L. Y., Humke, E. W., Xu, L., Wong, D. J., Willingham, S. B., Schwartz, E. J., Weissman, I. L., Jeffrey, S. S., Neal, J. W., Rohatgi, R., Wakelee, H. A., & Wang, S. X.
Affiliations
  • Stanford University (US)
  • Stanford Medicine (US)
  • Stanford Cancer Institute (US)
  • Institute for Stem Cell Biology and Regenerative Medicine (US)
Corresponding author
Wang, Shan X.
Venue
Lab Chip
Published
2014
Volume
14
Issue
1
Pages
78-88
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2020442157
Cited by
165
References
41
Citations by year
2026: 1 · 2025: 4 · 2024: 5 · 2023: 7 · 2022: 16 · 2021: 11 · 2020: 16 · 2019: 22 · 2018: 21 · 2017: 15 · 2016: 22 · 2015: 13 · 2014: 9
FWCI
8.47
Type
journal article
Language
en
Open access
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health (5u54ca143907-05)
  • National Cancer Institute (U54-CA-143907, R33CA138330, U54CA151459)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cancer Research › Cancer Genomics and Diagnostics
Keywords
circulating tumor cells, lung cancer, microfluidic cell capture, cell release, protein microarrays, mutation analysis, liquid biopsy, blood-based cancer detection
MeSH terms
Epithelial Cell Adhesion Molecule, Antigens, Neoplasm, Carcinoma, Non-Small-Cell Lung, Cell Separation, Humans, Keratins, Lung Neoplasms, Magnetics, Mutation, Neoplastic Cells, Circulating, Cell Adhesion Molecules, Fluorescein-5-isothiocyanate, Cell Line, Tumor, Microfluidic Analytical Techniques, Antibodies, Immobilized, Magnetite Nanoparticles, MCF-7 Cells, ErbB Receptors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isolation and mutational analysis of circulating tumor cells from lung cancer patients with magnetic sifters and biochips. https://app.cochat.ai/papers/10.1039/c3lc50580d
The paper
Earhart, C. M., Hughes, C. E., Gaster, R. S., Ooi, C. C., Wilson, R. J., Zhou, L. Y., Humke, E. W., Xu, L., Wong, D. J., Willingham, S. B., Schwartz, E. J., Weissman, I. L., Jeffrey, S. S., Neal, J. W., Rohatgi, R., Wakelee, H. A., & Wang, S. X. (2014). Isolation and mutational analysis of circulating tumor cells from lung cancer patients with magnetic sifters and biochips. Lab Chip. https://doi.org/10.1039/c3lc50580d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.