Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Open accessThe DOI matches its Crossref record; 15 of the 16 references it cites were found in a registry or an index.
Abstract
A need exists for technologies that permit the direct quantification of differences in protein and posttranslationally modified protein expression levels. Here we present a strategy for the absolute quantification (termed AQUA) of proteins and their modification states. Peptides are synthesized with incorporated stable isotopes as ideal internal standards to mimic native peptides formed by proteolysis. These synthetic peptides can also be prepared with covalent modifications (e.g., phosphorylation, methylation, acetylation, etc.) that are chemically identical to naturally occurring posttranslational modifications. Such AQUA internal standard peptides are then used to precisely and quantitatively measure the absolute levels of proteins and posttranslationally modified proteins after proteolysis by using a selected reaction monitoring analysis in a tandem mass spectrometer. In the present work, the AQUA strategy was used to ( i ) quantify low abundance yeast proteins involved in gene silencing, ( ii ) quantitatively determine the cell cycle-dependent phosphorylation of Ser-1126 of human separase protein, and ( iii ) identify kinases capable of phosphorylating Ser-1501 of separase in an in vitro kinase assay. The methods described here represent focused, alternative approaches for studying the dynamically changing proteome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In contrast to similar methods using labeled peptides as standards, such as AQUA peptides (Gerber et al, 2003), the protein fragments are digested simultaneously together with the target protein, which minimizes errors arising during sample preparation, such as the effect of incomplete trypsin digestion or sample loss prior addition of standard.”
From Gene‐specific correlation of RNA and protein levels in human cells and tissues (2016) · cites this paper as Gerber et al, 2003
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,995
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Self-citationCorrelation between Protein and mRNA Abundance in Yeast
Gygi, S. P., Rochon, Y., Franza, B. R., & Aebersold, R. (1999) · Molecular and Cellular Biology · doi:10.1128/mcb.19.3.1720 · Cited by 3,819
Self-citationPeng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647
Self-citationEvaluation of two-dimensional gel electrophoresis-based proteome analysis technology
Gygi, S. P., Corthals, G. L., Zhang, Y., Rochon, Y., & Aebersold, R. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.160270797 · Cited by 1,319
Self-citationA proteomic view of the Plasmodium falciparum life cycle
Florens, L., Washburn, M. P., Raine, J. D., Anthony, R. M., Grainger, M., Haynes, J. D., Moch, J. K., Muster, N., Sacci, J. B., Tabb, D. L., et al. (2002) · Nature · doi:10.1038/nature01107 · Cited by 1,308
Accurate quantitation of protein expression and site-specific phosphorylation
Oda, Y., Huang, K., Cross, F. R., Cowburn, D., & Chait, B. T. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.12.6591 · Cited by 1,006
Analysis of the Plasmodium falciparum proteome by high-accuracy mass spectrometry
Lasonder, E., Ishihama, Y., Andersen, J. S., Vermunt, A. M. W., Pain, A., Sauerwein, R. W., Eling, W. M. C., Hall, N., Waters, A. P., Stunnenberg, H. G., et al. (2002) · Nature · doi:10.1038/nature01111 · Cited by 652
Research works printed but not linked: 1
- Barnidge, D. R., Dratz, E. A., Martin, T., Bonilla, L. E., Moran, L. B. & Lindall, A. (2003) Anal. Chem. 75, 445–451. [DOI] [PubMed] [Google Scholar] · doi:10.1021/ac026154
Cited by
Items 401–500 of 1,002
Recent findings and technological advances in phosphoproteomics for cells and tissues
von Stechow, L., Francavilla, C., & Olsen, J. V. (2015) · Expert Review of Proteomics · doi:10.1586/14789450.2015.1078730 · Cited by 77
“Next to identifying the relative stoichiometry of phosphorylation, identifying absolute levels of phosphorylated peptides can be of interest [81].”
BackgroundPrókai, L., Zharikova, A. D., & Stevens, S. M. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.736 · Cited by 77
Stengel, F., Aebersold, R., & Robinson, C. V. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r111.014027 · Cited by 70
“cation (52, 76, 77) (for different strategies, see, for example, Ref.”
Blevins, W. R., Tavella, T., Moro, S. G., Blasco-Moreno, B., Closa-Mosquera, A., Díez, J., Carey, L. B., & Albà, M. M. (2019) · Scientific Reports · doi:10.1038/s41598-019-47424-w · Cited by 72
Yan, X., Xu, M., Yang, L., & Wang, Q. (2010) · Analytical Chemistry · doi:10.1021/ac902163x · Cited by 73
OMICS-strategies and methods in the fight against doping
Reichel, C. (2011) · Forensic Science International · doi:10.1016/j.forsciint.2011.07.031 · Cited by 73
Proteogenomic Approaches for the MolecularCharacterization of Natural Microbial Communities
Banfield, J. F., VerBerkmoes, N. C., Hettich, R. L., & Thelen, M. P. (2005) · OMICS A Journal of Integrative Biology · doi:10.1089/omi.2005.9.301 · Cited by 84
Schmidt, F., & Völker, U. (2011) · PROTEOMICS · doi:10.1002/pmic.201100158 · Cited by 83
“If stable isotopes are included, the user has the choice between isotopic labeling via isotope-coded affinity tagging (ICAT) [41], isobaric tagging for relative and absolute quantitation (iTRAQ), isobaric peptide termini labeling (IPTL) [42], absolute quantitation using standard peptides (AQUA) [43], and metabolic lab…”
MethodRegulation of the regulatory enzyme, 6-phosphofructo-2-kinase/fructose-2,6-bisphosphatase
Okar, D. A., Wu, C., & Lange, A. J. (2004) · Advances in Enzyme Regulation · doi:10.1016/j.advenzreg.2003.11.006 · Cited by 80
Navaza, A. P., Encinar, J. R., & Sanz‐Medel, A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200602517 · Cited by 80
Xue, L., Wang, P., Wang, L., Renzi, E. C., Predrag Radivojac, A., Tang, H., Arnold, R. J., Zhu, J., & Tao, W. A. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o113.027284 · Cited by 77
“Absolute quantification peptide technology (AQUA) (19), for example, uses synthetic peptides with isotope labeling for absolute quanti- From the ‡Departments of Biochemistry, Purdue University, West Lafayette, IN 47907; §Horticulture and Landscape Architecture, Purdue University, West Lafayette, IN 47907; ¶School of I…”
MethodInfluentialThe application of quantification techniques in proteomics for biomedical research
Rodríguez‐Suárez, E., & Whetton, A. D. (2012) · Mass Spectrometry Reviews · doi:10.1002/mas.21347 · Cited by 76
“The use of isotope-labeled synthetic peptides was originally described in the early 1980s (Desiderio & Kai, 1983) but it is now becoming more broadly applied since Gerber et al. (2003) developed the AQUA technique.”
MethodNeuroproteomics in neurotrauma
Ottens, A. K., Kobeissy, F. H., Golden, E. C., Zhang, Z., Haskins, W. E., Chen, S., Hayes, R. L., Wang, K., & Denslow, N. D. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20073 · Cited by 77
“Optimally, a synthetic version of the targeted tryptic peptide would be used with heavy isotopes of (2)H, (13)C, and (15)N for differentiation by MSMS (Gerber et al., 2003).”
BackgroundA Chaperone Trap Contributes to the Onset of Cystic Fibrosis
Coppinger, J. A., Hutt, D. M., Razvi, A., Koulov, A. V., Pankow, S., Yates, J. R., & Balch, W. E. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037682 · Cited by 69
“N-labeled protein based approaches to existing absolute quantification strategies based on AQUA synthetic peptides”
BackgroundBozzacco, L., Yu, H., A. Zebroski, H., Dengjel, J., Deng, H., Mojsov, S., & Steinman, R. M. (2011) · Journal of Proteome Research · doi:10.1021/pr200503g · Cited by 68
Hassan, C., Kester, M. G. D., Oudgenoeg, G., de Ru, A. H., Janssen, G. M. C., Drijfhout, J. W., Spaapen, R. M., Jiménez, C. R., Heemskerk, M. H. M., Falkenburg, J. H. F., et al. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.07.009 · Cited by 75
“Currently, the best copy number determinations are based on mass spectrometry, employing SRM in combination with mixing in a known amount of isotopically labeled peptide, known as the AQUA approach [3–6].”
BackgroundMethodMass Spectrometry-based Expression Profiling of Clinical Prostate Cancer
Wright, M. E., Han, D. K. M., & Aebersold, R. H. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r500008-mcp200 · Cited by 74
“More recently, several experimental approaches— one dubbed “AQUA,” which stands for absolute quantification of proteins (67, 68), and another called “VICAT,” which stands for visible isotope-coded affinity tag (66)—have been described that are directed at the selective isolation of proteins or peptides in complex samp…”
MethodRecent advancements in differential proteomics based on stable isotope coding
Julka, S., & Regnier, F. E. (2005) · Briefings in Functional Genomics and Proteomics · doi:10.1093/bfgp/4.2.158 · Cited by 72
Castro‐Borges, W., Simpson, D. M., Dowle, A., Curwen, R. S., THOMAS‐OATES, J. E., Beynon, R. J., & Wilson, R. A. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.06.011 · Cited by 78
Jenkins, R. E., Kitteringham, N. R., Hunter, C. L., Webb, S., Hunt, T., Elsby, R., Watson, R. B., Williams, D. P., Pennington, S. R., & Park, B. K. (2006) · PROTEOMICS · doi:10.1002/pmic.200500432 · Cited by 71
Zilkenat, S., Franz‐Wachtel, M., Stierhof, Y., Galán, J. E., Maček, B., & Wagner, S. (2016) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m115.056598 · Cited by 77
“1, see also for nomenclature), we have employed two complementing mass spectrometry (MS)-based strategies, using peptide concatenated standards (PCS) (25) and synthetic stable isotope-labeled peptides (26).”
Kulyyassov, A., Fresnais, M., & Longuespée, R. (2021) · PROTEOMICS · doi:10.1002/pmic.202100153 · Cited by 79
Pan, S., Rush, A. J., Peskind, E. R., Galasko, D., Chung, K. A., Quinn, J. F., Jankovic, J. J., Leverenz, J. B., Zabetian, C. P., Pan, C., et al. (2008) · Journal of Proteome Research · doi:10.1021/pr700630x · Cited by 74
The Geometry of Multisite Phosphorylation
Manrai, A. K., & Gunawardena, J. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.140632 · Cited by 74
Barnidge, D. R., Tschumper, R. C., Theis, J. D., Snyder, M. R., Jelinek, D. F., Katzmann, J. A., Dispenzieri, A. A., & Murray, D. L. (2014) · Journal of Proteome Research · doi:10.1021/pr5000544 · Cited by 70
Delcourt, V., Brunelle, M., Roy, A. V., Jacques, J., Salzet, M., Fournier, I., & Roucou, X. (2018) · Molecular & Cellular Proteomics · doi:10.1074/mcp.ra118.000593 · Cited by 76
“Absolute quantification PRM experiments were performed by spiking AQUA peptides with trypsin into the digestion mixture as described by [30].”
InfluentialLin, S., Wein, S., Gonzales-Cope, M., Otte, G. L., Yuan, Z.-F., Afjehi-Sadat, L., Maile, T., Berger, S. L., Rush, J., Lill, J. R., et al. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o113.036459 · Cited by 63
Hendrickson, R. C., Lee, A. Y. H., Song, Q., Liaw, A., Wiener, M., Paweletz, C. P., Seeburger, J. L., Li, J., Meng, F., Deyanova, E. G., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135365 · Cited by 69
“Using the AQUA approach ([59]), where stable-isotope peptides for each candidate-peptide were synthesized and used, these authors report an impressive interassay CVs less of less than 20% for all 30 proteins.”
MethodProteomics Investigations of HDL: Challenges and Promise
Vaisar, T. (2012) · Current Vascular Pharmacology · doi:10.2174/157016112800812755 · Cited by 79
Domanski, D., Murphy, L. C., & Borchers, C. H. (2010) · Analytical Chemistry · doi:10.1021/ac1005553 · Cited by 69
Ocaña, M. F., & Neubert, H. (2010) · Analytical Biochemistry · doi:10.1016/j.ab.2010.01.002 · Cited by 69
Zhao, Y., Jamaluddin, M., Zhang, Y., Sun, H., Ivanciuc, T., Garofalo, R. P., & Brasier, A. R. (2017) · The Journal of Immunology · doi:10.4049/jimmunol.1601291 · Cited by 71
Elemental tagging in inorganic mass spectrometric bioanalysis
Bettmer, J., Jakubowski, N., & Prange, A. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0557-4 · Cited by 69
Kim, H., Kim, K., Yu, S. J., Jang, E. S., Yu, J., Cho, G., Yoon, J., & Kim, Y. (2013) · PLoS ONE · doi:10.1371/journal.pone.0063468 · Cited by 68
“In MRM verification, specific peptides of candidates are selected to represent the protein from which they are quantitated against a spiked internal standard (a synthetic stable isotope-labeled peptide), yielding a measure of its concentration [10].”
BackgroundMass spectrometry approaches to study mammalian kinase and phosphatase associated proteins
Kean, M. J., Couzens, A. L., & Gingras, A. (2012) · Methods · doi:10.1016/j.ymeth.2012.06.002 · Cited by 76
Yan, X., Luo, Y., Zhang, Z., Li, Z., Luo, Q., Yang, L., Zhang, B., Chen, H., Bai, P., & Wang, Q. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201108277 · Cited by 71
Redlich, G., Zanger, U. M., Riedmaier, S., Bache, N., Giessing, A. M. B., Eisenacher, M., Stephan, C., Meyer, H. E., Jensen, O. N., & Marcus, K. (2008) · Journal of Proteome Research · doi:10.1021/pr800231w · Cited by 78
Whiteaker, J. R., Zhao, L., Lin, C., Yan, P., Wang, P., & Paulovich, A. G. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.015347 · Cited by 70
Targeted proteomics: Current status and future perspectives for quantification of food allergens
Ahsan, N., Rao, R. S. P., Gruppuso, P. A., Ramratnam, B., & Salomon, A. R. (2016) · Journal of Proteomics · doi:10.1016/j.jprot.2016.04.018 · Cited by 71
“The physiochemical and chromatographic properties such as retention time and ionization efficiency of the AQUA standards are nearly identical to the native target peptides except for the inclusion of heavy-isotopes of an amino acid which distinguishes the standards from the native peptides by a mass shift [66].”
BackgroundLow, J. K. K., Silva, A. P. G., Sharifi Tabar, M., Torrado, M., Webb, S. R., Parker, B. L., Sana, M., Smits, C., Schmidberger, J. W., Brillault, L., et al. (2020) · Cell Reports · doi:10.1016/j.celrep.2020.108450 · Cited by 66
“Subunit stoichiometry derived from DIA-MS data for MTAN-HDAC-MBDGATAD2CC and MTA-HDAC-MBD-GATAD2 complexes.”
MethodInfluentialJi, C., Sadagopan, N., Zhang, Y., & Lepsy, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac901800f · Cited by 67
Oudenhove, L. V., & Devreese, B. V. (2013) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-013-4897-7 · Cited by 74
“Gerber et al. (2003) proposed an absolute quantification (AQUA) strategy for proteins as well as their posttranslationally modified forms, in which synthetic proteotypic peptides with incorporated stable isotopes are used as the ideal internal standard.”
BackgroundThe role of sulfur and sulfur isotope dilution analysis in quantitative protein analysis
Rappel, C., & Schaumlöffel, D. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1607-2 · Cited by 67
Proteomics and its applications for food authentication and food-technology research
Gallardo, J. M., Ortea, I., & Carrera, M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.05.019 · Cited by 74
Proteomics of industrial fungi: trends and insights for biotechnology
de Oliveira, J. M. P. F., & de Graaff, L. H. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2900-0 · Cited by 78
Ackermann, B., Berna, M., Eckstein, J., Ott, L., & Chaudhary, A. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112855 · Cited by 68
Quantitative Protein Analysis by Mass Spectrometry
Pagala, V., High, A. A., Wang, X., Tan, H., Kodali, K., Mishra, A., Kavdia, K., Xu, Y., Wu, Z., & Peng, J. (2015) · Methods in molecular biology · doi:10.1007/978-1-4939-2425-7_17 · Cited by 74
Genomics and proteomics: Emerging technologies in clinical cancer research
Chung, C. H., Levy, S., Chaurand, P., & Carbone, D. P. (2006) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2006.06.005 · Cited by 74
“[128] Gerber SA, Rush J, Stemman O, Kirschner MW, Gygi SP.”
BackgroundData processing methods and quality control strategies for label-free LC–MS protein quantification
Sandin, M., Teleman, J., Malmström, J. A., & Levander, F. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2013.03.026 · Cited by 76
Quantitative proteomics of complex mixtures
Coombs, K. M. (2011) · Expert Review of Proteomics · doi:10.1586/epr.11.55 · Cited by 69
Addressing proteolytic efficiency in enzymatic degradation therapy for celiac disease
Rey, M., Yang, M., Lee, L., Zhang, Y., Sheff, J. G., Sensen, C. W., Mrázek, H., Halada, P., Man, P., McCarville, J. L., et al. (2016) · Scientific Reports · doi:10.1038/srep30980 · Cited by 71
Clinical protein mass spectrometry
Scherl, A. (2015) · Methods · doi:10.1016/j.ymeth.2015.02.015 · Cited by 69
Stoichiometry and Phosphoisotypes of Hippocampal AMPA-Type Glutamate Receptor Phosphorylation
Hosokawa, T., Mitsushima, D., Kaneko, R., & Hayashi, Y. (2015) · Neuron · doi:10.1016/j.neuron.2014.11.026 · Cited by 63
Simpson, D. M., & Beynon, R. J. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6230-1 · Cited by 68
Analysis of protein carbonylation — pitfalls and promise in commonly used methods
Rogowska-Wrzesinska, A., Wojdyla, K., Nedić, O., Baron, C. P., & Griffiths, H. R. (2014) · Free Radical Research · doi:10.3109/10715762.2014.944868 · Cited by 65
“Examples of this approach are AQUA [88] and QconCAT [89], which utilize isotope labeled peptides.”
MethodPaul, D., Kumar, A., Gajbhiye, A., Santra, M. K., & Srikanth, R. (2013) · BioMed Research International · doi:10.1155/2013/783131 · Cited by 75
“successfully used this method for absolute quantification of proteins and phosphoproteins from cell lysates [67].”
Development of an immuno tandem mass spectrometry (iMALDI) assay for EGFR diagnosis
Jian, J., Parker, C. E., Hoadley, K. A., Perou, C. M., Boysen, G., & Borchers, C. H. (2007) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.200700009 · Cited by 65
“This amount of digested EGFR protein is the same as the amount in the original cell lysate and cells, assuming 100% efficiency of the digestion reaction and the protein extraction upon cell lysis [19].”
BackgroundReid, G. E., Roberts, K. D., Simpson, R. J., & O’Hair, R. A. J. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.03.015 · Cited by 65
“The approach could also by readily applied to the “absolute” quantitative analysis of protein expression, in an analogous manner to recent reports whereby a known quantity of an isotopically encoded peptide of interest is “spiked” into a°sample°of°interest°as°an°internal°standard°[101].”
BackgroundBuilding Protein-Protein Interaction Networks with Proteomics and Informatics Tools
Sardiu, M. E., & Washburn, M. P. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.r110.174052 · Cited by 60
Direct quantitation of MHC‐bound peptide epitopes by selected reaction monitoring
Tan, C. T., Croft, N. P., Dudek, N. L., Williamson, N. A., & Purcell, A. W. (2011) · PROTEOMICS · doi:10.1002/pmic.201000531 · Cited by 64
“In essence, it searches for the mass spectral fingerprint of the peptide(s) being monitored and, when combined with an isotopically labelled internal peptide standard, allows absolute quantitation (AQUA) in the same experiment [5, 7].”
MethodPollreisz, A., Funk, M., Breitwieser, F. P., Parapatics, K., Sacu, S., Georgopoulos, M., Dunavoelgyi, R., Zlabinger, G. J., Colinge, J., Bennett, K. L., et al. (2012) · Experimental Eye Research · doi:10.1016/j.exer.2012.11.010 · Cited by 64
Ottens, A. K., Golden, E. C., Bustamante, L., Hayes, R. L., Denslow, N. D., & Wang, K. (2007) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2007.05086.x · Cited by 67
“In this study, we adapted isotope dilution analysis (IDA) (Barr et al. 1996; Gerber et al. 2003) for the novel purpose of quantifying proteolytic processes, in particular the calpain-induced fragmentation of MBP following TBI in rats.”
MethodInfluentialA Modified “Cross-talk” between Histone H2B Lys-120 Ubiquitination and H3 Lys-79 Methylation
Darwanto, A., Curtis, M. P., Schrag, M., Kirsch, W. M., Liu, P., Xu, G., Neidigh, J. W., & Zhang, K. (2010) · Journal of Biological Chemistry · doi:10.1074/jbc.m110.126813 · Cited by 68
If the antibody fails – a mass Western approach
Lehmann, U., Wienkoop, S., Tschoep, H., & Weckwerth, W. (2008) · The Plant Journal · doi:10.1111/j.1365-313x.2008.03554.x · Cited by 69
“These synthetic peptides can be used to optimize the selectivity and sensitivity of a mass spectrometer (Gerber et al., 2003; Glinski and Weckwerth, 2005; Wienkoop and Weckwerth, 2006).”
BackgroundMass spectrometry in nutrition: Understanding dietary health effects at the molecular level
Kussmann, M., Affolter, M., Nagy, K., Holst, B., & Fay, L. B. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20147 · Cited by 70
“…of LC-MS/MS data and display of three-dimensional peptide maps (m/z, retention time and peak intensity) (Higgs et al., 2005); and (d) absolute protein quantification by spiking ‘‘proteotypic’’ peptides representative of each protein of interest as internal standards (Gerber et al., 2003).”
BackgroundMethodAnalysis of the Saccharomyces cerevisiae proteome with PeptideAtlas
King, N. L., Deutsch, E. W., Ranish, J. A., Nesvizhskii, A. I., Eddes, J. S., Mallick, P., Eng, J., Desiere, F., Flory, M., Martin, D. B., et al. (2006) · Genome Biology · doi:10.1186/gb-2006-7-11-r106 · Cited by 65
“9 ) Genome Biology 2006, 7: R106 multi-protein complex [32] or to determine the absolute quantity of a protein in a sample [33,34].”
BackgroundHaskins, W. E., Kobeissy, F. H., Wolper, R. A., Ottens, A. K., Kitlen, J. W., McClung, S. H., O'Steen, B. E., Chow, M. M., Pineda, J., Denslow, N. D., et al. (2005) · Journal of Neurotrauma · doi:10.1089/neu.2005.22.629 · Cited by 63
“Absolute quantification (AQUA) (Gerber et al., 2003) of these proteins can be readily achieved by incorporating an isotopically labeled tryptic peptide as an internal standard during trypsin digestion (publication in preparation).”
Li, N., Nemirovskiy, O. V., Zhang, Y., Yuan, H., Mo, J., Ji, C., Zhang, B., Brayman, T. G., Lepsy, C. S., Heath, T. G., et al. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.05.032 · Cited by 70
Faria, S. S., Morris, C. F. M., Silva, A. R., Fonseca, M. P., Forget, P., Castro, M. S., & Fontes, W. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00013 · Cited by 58
“org February 2017 | Volume 7 | Article 13 (AQUA peptides) (149).”
Seibert, C., Davidson, B. R., Fuller, B. J., Patterson, L. H., Griffiths, W. J., & Wang, Y. (2008) · Journal of Proteome Research · doi:10.1021/pr800795r · Cited by 66
Balogh, L. M. (2013) · Journal of Proteomics & Bioinformatics · doi:10.4172/jpb.1000285 · Cited by 67
“Among the common method descriptors is the absolute quantification (AQUA) method in which synthesized stable isotopelabeled (SIL) peptide standards are added to digested samples [29].”
MethodChampion, M. M., Williams, E. A., Pinapati, R. S., & Champion, P. A. D. (2014) · Journal of Proteome Research · doi:10.1021/pr500484w · Cited by 60
Rolland, N., Atteia, A., Decottignies, P., Garin, J., Hippler, M., Kreimer, G., Lemaire, S. D., Mittag, M., & Wagner, V. (2009) · Current Opinion in Microbiology · doi:10.1016/j.mib.2009.04.001 · Cited by 62
Free computational resources for designing selected reaction monitoring transitions
Cham, J. A., Bianco, L., & Bessant, C. (2010) · PROTEOMICS · doi:10.1002/pmic.200900396 · Cited by 66
“This ratio is also useful for AQUA [20] and SILAC [65] experiments, which can also be optimized using MRMer.”
MethodAdvances in Mass Spectrometric Tools for Probing Neuropeptides
Buchberger, A. R., Yu, Q., & Li, L. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040210 · Cited by 69
“(75) later developed the absolute quantification of proteins.”
BackgroundWilliams, D. K., & Muddiman, D. C. (2009) · Journal of Proteome Research · doi:10.1021/pr800922p · Cited by 64
Phosphorylation of Jak2 on Ser 523 InhibitsJak2-Dependent Leptin ReceptorSignaling
Ishida-Takahashi, R., Rosario, F., Gong, Y., Kopp, K., Stancheva, Z., Chen, X., Feener, E. P., & Myers, M. G. (2006) · Molecular and Cellular Biology · doi:10.1128/mcb.01589-05 · Cited by 60
“We thus employed LC-SRM using mass-tagged synthetic peptide standards (13) in order to examine the stoichiometry of Ser523 phosphorylation on Jak2 from HEK293 cells.”
Methodvan den Broek, I., Blokland, M., Nessen, M. A., & Sterk, S. S. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21419 · Cited by 66
“Although SIL-peptide internal standards, also named Absolute Quantification or AQUA peptides (Gerber et al., 2003), are easily available and simple in use, they suffer from quantification uncertainties introduced before and during enzymatic digestion of the target protein (Arsene et al.”
BackgroundIntroduction to Mass Spectrometry-Based Proteomics
Matthiesen, R., & Bunkenborg, J. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-392-3_1 · Cited by 70
A practical data processing workflow for multi-OMICS projects
Kohl, M., Megger, D. A., Trippler, M., Meckel, H., Ahrens, M., Bracht, T., Weber, F., Hoffmann, A.-C., Baba, H. A., Sitek, B., et al. (2014) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2013.02.029 · Cited by 60
“Additionally, labeling enables the absolute quantitation of protein changes even within complex protein samples (AQUA method, [59]).”
MethodLehmann, S., Hoofnagle, A., Hochstrasser, D., Brede, C., Glueckmann, M., Cocho, J. A., Ceglarek, U., Lenz, C., Vialaret, J., Scherl, A., et al. (2013) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm-2012-0723 · Cited by 59
Regulation of class IA PI3Ks: is there a role for monomeric PI3K subunits?
Geering, B., Cutillas, P. R., & Vanhaesebroeck, B. (2007) · Biochemical Society Transactions · doi:10.1042/bst0350199 · Cited by 63
Tanca, A., Pagnozzi, D., & Addis, M. F. (2011) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201100044 · Cited by 60
“Moreover, the absolute quantification (AQUA) methodology [77] was applied to quantify PSA in the FFPE tissue extract, and a putative biomarker as the Wnt-3 protein was confirmed as upregulated in cancerous cells by IHC.”
MethodRussell, M. R., Achour, B., McKenzie, E. A., Lopez, R., Harwood, M. D., Rostami‐Hodjegan, A., & Barber, J. (2013) · Journal of Proteome Research · doi:10.1021/pr400279u · Cited by 60
Quantitative isoform-profiling of highly diversified recognition molecules
Schreiner, D., Simicevic, J., Ahrné, E., Schmidt, A., & Scheiffele, P. (2015) · eLife · doi:10.7554/elife.07794 · Cited by 57
“During the development of our study, we evaluated the use of AQUA synthetic peptides (Gerber et al., 2003) for quantification of brain protein repertoires.”
Biomarker Discovery in Animal Health and Disease: The Application of Post-Genomic Technologies
Moore, R. E., Kirwan, J., Doherty, M. K., & Whitfield, P. D. (2007) · Biomarker Insights · doi:10.1177/117727190700200040 · Cited by 54
Application of isotope dilution ICP–MS techniques to quantitative proteomics
Bettmer, J. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3861-y · Cited by 69
Systems biology from a yeast omics perspective
Snyder, M. P., & Gallagher, J. E. G. (2009) · FEBS Letters · doi:10.1016/j.febslet.2009.11.011 · Cited by 64
“…from the limited number of recent studies, over 12 000 high confidence phosphorylation sites on (cid:2) 50% of yeast proteins have been identified in yeast using mass spectrometry [41–44] and the number of phosphorylated sites is expected to grow even higher as additional sites continue to be mapped.”
BackgroundQuantitative phosphoproteomics – an emerging key technology in signal‐transduction research
Schreiber, T. B., Mäusbacher, N., Breitkopf, S. B., Grundner‐Culemann, K., & Daub, H. (2008) · PROTEOMICS · doi:10.1002/pmic.200800132 · Cited by 60
“cells, as losses during protein extraction and further sample processing are not accounted for in the AQUA approach [45, 46].”
BackgroundQuantitative analysis of protein turnover in plants
Nelson, C. J., Li, L., & Millar, A. H. (2014) · PROTEOMICS · doi:10.1002/pmic.201300240 · Cited by 76
“For absolute quantitation, stable isotope labelling of representative peptides [27] or entire proteins works well [28].”
BackgroundGarcía‐Giménez, J. L., Mateo, C. R., Carbonell, N., Palacios, L., Peiró-Chova, L., García-López, E., García-Simón, M., Lahuerta, R., Giménez‐Garzó, C., Berenguer-Pascual, E., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-10830-z · Cited by 62
Relative quantification in proteomics: new approaches for biochemistry
Unwin, R. D., Evans, C. A., & Whetton, A. D. (2006) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2006.06.003 · Cited by 66
Cutillas, P. R., Geering, B., Waterfield, M. D., & Vanhaesebroeck, B. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500078-mcp200 · Cited by 61
“mimic a peptide derived from the target protein (8).”
BackgroundUBB pseudogene 4 encodes functional ubiquitin variants
Dubois, M., Meller, A., Samandi, S., Brunelle, M., Frion, J., Brunet, M. A., Toupin, A., Beaudoin, M. C., Jacques, J., Lévesque, D., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15090-6 · Cited by 60
Receptor tyrosine kinase signaling: a view from quantitative proteomics
Dengjel, J., Kratchmarova, I., & Blagoev, B. (2009) · Molecular BioSystems · doi:10.1039/b909534a · Cited by 56
Method and platform standardization in MRM-based quantitative plasma proteomics
Percy, A. J., Chambers, A. G., Yang, J., Jackson, A., Domański, D., Burkhart, J. M., Sickmann, A., & Borchers, C. H. (2013) · Journal of Proteomics · doi:10.1016/j.jprot.2013.07.026 · Cited by 61
Dahlin, A. P., Wetterhall, M., Caldwell, K. D., Larsson, A. O., Bergquist, J., Hillered, L., & Hjort, K. (2010) · Analytical Chemistry · doi:10.1021/ac1007706 · Cited by 63
History of inductively coupled plasma mass spectrometry-based immunoassays
Giesen, C., Waentig, L., Panne, U., & Jakubowski, N. (2012) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2012.06.009 · Cited by 66
Ciccimaro, E., Hanks, S. K., Yu, K. H., & Blair, I. A. (2009) · Analytical Chemistry · doi:10.1021/ac900204f · Cited by 62
Presence of the Adenovirus IVa2 Protein at a Single Vertex of the Mature Virion
Christensen, J. B., Byrd, S., Walker, A. K., Strahler, J. R., Andrews, P., & Imperiale, M. J. (2008) · Journal of Virology · doi:10.1128/jvi.01024-08 · Cited by 58
“(9) to determine the relative molar ratios of selected tryptic peptides derived from penton, which has a known copy number of 60 per virion, and from IVa2.”
Background
Metadata
- Authors
- Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P.
- Affiliations
- Harvard University (US)
- Department of Cell Biology, Harvard Medical School, Boston, MA 02115; and Cell Signaling Technology, Inc., Beverly, MA 01915
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-05-27
- Volume
- 100
- Issue
- 12
- Pages
- 6940-6945
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC165809
- OpenAlex
- W2068481474
- Cited by
- 1,733
- References
- 16
- Citations by year
- 2026: 17 · 2025: 23 · 2024: 23 · 2023: 34 · 2022: 36 · 2021: 34 · 2020: 44 · 2019: 62 · 2018: 56 · 2017: 68 · 2016: 78 · 2015: 94 · 2014: 117 · 2013: 136 · 2012: 159
- FWCI
- 24.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- ERef Bayreuth (University of Bayreuth) (submittedVersion)
- Funders
- National Human Genome Research Institute (HG000 41, T32HG000041, K22HG000041)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ubiquitin and proteasome pathways
- Keywords
- absolute protein quantification, Aqua, isotope-labeled internal standards, post-translational modification, phosphoproteins, multiple reaction monitoring, tandem mass spectrometry, separase, gene silencing, yeast proteome, kinase identification, in vitro kinase assay
- MeSH terms
- Amino Acid Sequence, Animals, Binding Sites, HeLa Cells, Histone Deacetylases, Horses, Humans, Molecular Sequence Data, Myoglobin, Endopeptidases, Phosphoproteins, Phosphorylation, Protein Kinases, Proteins, Mass Spectrometry, Cell Cycle Proteins, Saccharomyces cerevisiae Proteins, Sirtuins, Silent Information Regulator Proteins, Saccharomyces cerevisiae, Sirtuin 2, Separase, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.