Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Open accessThe DOI matches its Crossref record; 15 of the 16 references it cites were found in a registry or an index.
Abstract
A need exists for technologies that permit the direct quantification of differences in protein and posttranslationally modified protein expression levels. Here we present a strategy for the absolute quantification (termed AQUA) of proteins and their modification states. Peptides are synthesized with incorporated stable isotopes as ideal internal standards to mimic native peptides formed by proteolysis. These synthetic peptides can also be prepared with covalent modifications (e.g., phosphorylation, methylation, acetylation, etc.) that are chemically identical to naturally occurring posttranslational modifications. Such AQUA internal standard peptides are then used to precisely and quantitatively measure the absolute levels of proteins and posttranslationally modified proteins after proteolysis by using a selected reaction monitoring analysis in a tandem mass spectrometer. In the present work, the AQUA strategy was used to ( i ) quantify low abundance yeast proteins involved in gene silencing, ( ii ) quantitatively determine the cell cycle-dependent phosphorylation of Ser-1126 of human separase protein, and ( iii ) identify kinases capable of phosphorylating Ser-1501 of separase in an in vitro kinase assay. The methods described here represent focused, alternative approaches for studying the dynamically changing proteome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In contrast to similar methods using labeled peptides as standards, such as AQUA peptides (Gerber et al, 2003), the protein fragments are digested simultaneously together with the target protein, which minimizes errors arising during sample preparation, such as the effect of incomplete trypsin digestion or sample loss prior addition of standard.”
From Gene‐specific correlation of RNA and protein levels in human cells and tissues (2016) · cites this paper as Gerber et al, 2003
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,995
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Self-citationCorrelation between Protein and mRNA Abundance in Yeast
Gygi, S. P., Rochon, Y., Franza, B. R., & Aebersold, R. (1999) · Molecular and Cellular Biology · doi:10.1128/mcb.19.3.1720 · Cited by 3,819
Self-citationPeng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647
Self-citationEvaluation of two-dimensional gel electrophoresis-based proteome analysis technology
Gygi, S. P., Corthals, G. L., Zhang, Y., Rochon, Y., & Aebersold, R. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.160270797 · Cited by 1,319
Self-citationA proteomic view of the Plasmodium falciparum life cycle
Florens, L., Washburn, M. P., Raine, J. D., Anthony, R. M., Grainger, M., Haynes, J. D., Moch, J. K., Muster, N., Sacci, J. B., Tabb, D. L., et al. (2002) · Nature · doi:10.1038/nature01107 · Cited by 1,308
Accurate quantitation of protein expression and site-specific phosphorylation
Oda, Y., Huang, K., Cross, F. R., Cowburn, D., & Chait, B. T. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.12.6591 · Cited by 1,006
Analysis of the Plasmodium falciparum proteome by high-accuracy mass spectrometry
Lasonder, E., Ishihama, Y., Andersen, J. S., Vermunt, A. M. W., Pain, A., Sauerwein, R. W., Eling, W. M. C., Hall, N., Waters, A. P., Stunnenberg, H. G., et al. (2002) · Nature · doi:10.1038/nature01111 · Cited by 652
Research works printed but not linked: 1
- Barnidge, D. R., Dratz, E. A., Martin, T., Bonilla, L. E., Moran, L. B. & Lindall, A. (2003) Anal. Chem. 75, 445–451. [DOI] [PubMed] [Google Scholar] · doi:10.1021/ac026154
Cited by
Items 101–200 of 1,002
Swan, A. L., Mobasheri, A., Allaway, D., Liddell, S., & Bacardit, J. (2013) · OMICS: A Journal of Integrative Biology · doi:10.1089/omi.2013.0017 · Cited by 249
“Finally, there are methods that result in absolute protein quantitation, including those that use stable isotope labeling standards, such as AQUA and Qcon-CAT (Beynon et al., 2005; Gerber et al., 2003).”
MethodChen, S., & Harmon, A. C. (2006) · PROTEOMICS · doi:10.1002/pmic.200600143 · Cited by 255
Methods for samples preparation in proteomic research
Bodzon-Kulakowska, A., Bierczynska-Krzysik, A., Dylag, T., Drabik, A., Suder, P., Noga, M., Jarzebinska, J., & Silberring, J. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.10.040 · Cited by 254
Scientific Opinion on the evaluation of allergenic foods and food ingredients for labelling purposes
EFSA Panel on Dietetic Products, N. A. A. (. (2014) · EFSA Journal · doi:10.2903/j.efsa.2014.3894 · Cited by 239
Chung, C.-S., Chen, C.-H., Ho, M.-Y., Huang, C.-Y., Liao, C.-L., & Chang, W. (2006) · Journal of Virology · doi:10.1128/jvi.80.5.2127-2140.2006 · Cited by 253
“Although quantification of particular proteins of interest using isotope-labeled synthetic peptides, termed Protein-AQUA, is in principle applicable to comprehensive analyses (12, 64), it is hampered by the high cost of isotope-labeled peptides and the difficulty of quantitative digestion of proteins in gel (73).”
BackgroundBarnidge, D. R., Goodmanson, M. K., Klee, G. G., & Muddiman, D. C. (2004) · Journal of Proteome Research · doi:10.1021/pr049963d · Cited by 253
No evidence for a shift in pyruvate kinase PKM1 to PKM2 expression during tumorigenesis
Bluemlein, K., Grüning, N.-M., Feichtinger, R. G., Lehrach, H., Kofler, B., & Ralser, M. (2011) · Oncotarget · doi:10.18632/oncotarget.278 · Cited by 253
“com/oncotarget synthesized, heavy-isotope labeled peptide standards (AQUA peptides) that match the proteolytic peptide of interest in sequence, but are distinguishable from the analyte by mass [14, 15, 17].”
BackgroundMethodAdvancing the sensitivity of selected reaction monitoring‐based targeted quantitative proteomics
Shi, T., Su, D., Liu, T., Tang, K., Camp, D. G., Qian, W., & Smith, R. D. (2012) · PROTEOMICS · doi:10.1002/pmic.201100436 · Cited by 245
“first reported the concept of absolute quantification with internal standard peptides coupled with IMAC enrichment of phosphopeptides and LC-SRM for quantifying the dynamic changes in phosphoproteins [37].”
BackgroundProtein Identification by Mass Spectrometry
Baldwin, M. A. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r300012-mcp200 · Cited by 229
A Proteomic Strategy for Gaining Insights into Protein Sumoylation in Yeast
Denison, C., Rudner, A. D., Gerber, S. A., Bakalarski, C. E., Moazed, D., & Gygi, S. P. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400154-mcp200 · Cited by 245
Self-citationWeckwerth, W. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.07.010 · Cited by 239
MacLean, B., Tomazela, D. M., Abbatiello, S. E., Zhang, S., Whiteaker, J. R., Paulovich, A. G., Carr, S. A., & MacCoss, M. J. (2010) · Analytical Chemistry · doi:10.1021/ac102179j · Cited by 238
Multiple Phosphorylations in the C-terminal Tail of Plant Plasma Membrane Aquaporins
Prak, S., Hem, S., Boudet, J., Viennois, G., Sommerer, N., Rossignol, M., Maurel, C., & Santoni, V. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700566-mcp200 · Cited by 243
“The unmodified C-terminal AtPIP2;1 peptide and its singly and diphosphorylated forms were quantified using a strategy adapted from the absolute quantification method (38).”
MethodThe translation of non-canonical open reading frames controls mucosal immunity
Jackson, R., Kroehling, L., Khitun, A., Bailis, W., Jarret, A., York, A. G., Khan, O. M., Brewer, J. R., Skadow, M. H., Duizer, C., et al. (2018) · Nature · doi:10.1038/s41586-018-0794-7 · Cited by 242
“Peptide standards (JPT Peptide Technologies) with 13C(6)15N(4) R isotopic labels were added to a final concentration of 100 ng/mL 44 .”
Mass spectrometry–based functional proteomics: from molecular machines to protein networks
Köcher, T., & Superti-Furga, G. (2007) · Nature Methods · doi:10.1038/nmeth1093 · Cited by 241
“Absolute quantitation of proteins can be achieved by spiking a single sample with isotopically labeled standard peptide”
Mapping and analysis of phosphorylation sites: a quick guide for cell biologists
Dephoure, N., Gould, K. L., Gygi, S. P., & Kellogg, D. R. (2013) · Molecular Biology of the Cell · doi:10.1091/mbc.e12-09-0677 · Cited by 241
“An alternative, targeted approach, termed AQUA, uses isotope-labeled synthetic peptides spiked into the experimental sample at a known concentration to provide absolute quantification (Gerber et al., 2003).”
BackgroundSelf-citationGli Protein Activity Is Controlled by Multisite Phosphorylation in Vertebrate Hedgehog Signaling
Niewiadomski, P., Kong, J. H., Ahrends, R., Ma, Y., Humke, E. W., Khan, S., Teruel, M. N., Novitch, B. G., & Rohatgi, R. (2014) · Cell Reports · doi:10.1016/j.celrep.2013.12.003 · Cited by 239
“Instead, we developed a mass spectrometry (MS)-based selected reaction monitoring (SRM) assay to quantitatively assess phosphate occupancy at P1, P2, P5, and P6 (Cox et al., 2005; Gerber et al., 2003; Mayya et al., 2006).”
In vivo discovery of immunotherapy targets in the tumour microenvironment
Zhou, P., Shaffer, D. R., Alvarez Arias, D. A., Nakazaki, Y., Pos, W., Torres, A. J., Cremasco, V., Dougan, S. K., Cowley, G. S., Elpek, K., et al. (2014) · Nature · doi:10.1038/nature12988 · Cited by 237
Robust and Sensitive iTRAQ Quantification on an LTQ Orbitrap Mass Spectrometer
Bantscheff, M., Boesche, M., Eberhard, D., Matthieson, T., Sweetman, G., & Kuster, B. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800029-mcp200 · Cited by 235
Class IA phosphoinositide 3-kinases are obligate p85-p110 heterodimers
Geering, B., Cutillas, P. R., Nock, G., Gharbi, S. I., & Vanhaesebroeck, B. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700373104 · Cited by 225
Multi-omics data integration considerations and study design for biological systems and disease
Graw, S., Chappell, K., Washam, C. L., Gies, A., Bird, J., Robeson, M. S., & Byrum, S. D. (2020) · Molecular Omics · doi:10.1039/d0mo00041h · Cited by 220
Paulovich, A. G., Whiteaker, J. R., Hoofnagle, A. N., & Wang, P. (2008) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.200780174 · Cited by 231
“Typical LOQ are in the range of 100–1000 ng/mL of target protein in plasma [32,45,48].”
BackgroundShi, T., Fillmore, T. L., Sun, X., Zhao, R., Schepmoes, A. A., Hossain, M., Xie, F., Wu, S., Kim, J.-S., Jones, N., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204366109 · Cited by 224
Stable-Isotope Dilution LC–MS for Quantitative Biomarker Analysis
Ciccimaro, E., & Blair, I. A. (2010) · Bioanalysis · doi:10.4155/bio.09.185 · Cited by 226
Liquid Chromatography-Mass Spectrometry-based Quantitative Proteomics
Xie, F., Liu, T., Qian, W.-J., Petyuk, V. A., & Smith, R. D. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.r110.199703 · Cited by 215
Absolute SILAC for Accurate Quantitation of Proteins in Complex Mixtures Down to the Attomole Level
Hanke, S., Besir, H., Oesterhelt, D., & Mann, M. (2008) · Journal of Proteome Research · doi:10.1021/pr7007175 · Cited by 216
Li, W., Li, F., Zhang, X., Lin, H.-K., & Xu, C. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00825-8 · Cited by 198
“Many of these enzymes in UBL modification are identified by labeling dependent and independent quantitative proteomics, such as the reported stable isotope labeling by amino acids(SILAC) in cell culture through metabolic incorporation,(147,148) isobaric tags for relative and absolute quantification (iTRAQ),(149) and t…”
BackgroundAbbatiello, S. E., Schilling, B., Mani, D. R., Zimmerman, L. J., Hall, S. C., MacLean, B., Albertolle, M., Allen, S., Burgess, M., Cusack, M. P., et al. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.047050 · Cited by 215
Quantitative mouse brain proteomics using culture-derived isotope tags as internal standards
Ishihama, Y., Sato, T., Tabata, T., Miyamoto, N., Sagane, K., Nagasu, T., & Oda, Y. (2005) · Nature Biotechnology · doi:10.1038/nbt1086 · Cited by 211
A database of mass spectrometric assays for the yeast proteome
Picotti, P., Lam, H., Campbell, D., Deutsch, E. W., Mirzaei, H., Ranish, J., Domon, B., & Aebersold, R. (2008) · Nature Methods · doi:10.1038/nmeth1108-913 · Cited by 211
Schubert, O. T., Ludwig, C., Kogadeeva, M., Zimmermann, M., Rosenberger, G., Gengenbacher, M., Gillet, L. C., Collins, B. C., Röst, H. L., Kaufmann, S. H. E., et al. (2015) · Cell Host & Microbe · doi:10.1016/j.chom.2015.06.001 · Cited by 211
Ballif, B. A., Roux, P. P., Gerber, S. A., MacKeigan, J. P., Blenis, J., & Gygi, S. P. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409143102 · Cited by 211
Self-citationSchmid, A. W., Fauvet, B., Moniatte, M., & Lashuel, H. A. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r113.032730 · Cited by 212
“lated counterparts using targeted MS methods (85).”
MethodSKAR Is a Specific Target of S6 Kinase 1 in Cell Growth Control
Richardson, C. J., Bröenstrup, M., Fingar, D. C., Jülich, K., Ballif, B. A., Gygi, S., & Blenis, J. (2004) · Current Biology · doi:10.1016/j.cub.2004.08.061 · Cited by 198
Self-citationSystems Biology in Immunology: A Computational Modeling Perspective
Germain, R. N., Meier-Schellersheim, M., Nita-Lazar, A., & Fraser, I. D. C. (2011) · Annual Review of Immunology · doi:10.1146/annurev-immunol-030409-101317 · Cited by 203
Functional proteomics to dissect tyrosine kinase signalling pathways in cancer
Kolch, W., & Pitt, A. (2010) · Nature Reviews Cancer · doi:10.1038/nrc2900 · Cited by 200
Steen, H., Jebanathirajah, J. A., Springer, M., & Kirschner, M. W. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0409536102 · Cited by 206
Self-citationMultiple Signaling Roles of CD3ε and Its Application in CAR-T Cell Therapy
Wu, W., Zhou, Q., Masubuchi, T., Shi, X., Li, H., Xu, X., Huang, M., Meng, L., He, X., Zhu, H., et al. (2020) · Cell · doi:10.1016/j.cell.2020.07.018 · Cited by 197
Proteomic analysis of Schistosoma mansoni egg secretions
Cass, C. L., Johnson, J. R., Califf, L. L., Xu, T., Hernandez, H. J., Stadecker, M. J., Yates, J. R., & Williams, D. L. (2007) · Molecular and Biochemical Parasitology · doi:10.1016/j.molbiopara.2007.06.002 · Cited by 205
“The advantage to other approaches is that the identification of components is much more comprehensive, but the relative abundance of those components can never be exactly quantified without absolute quantitative measures that are quite low-throughput and costly [36].”
BackgroundLange, V., Malmström, J. A., Didion, J., King, N. L., Johansson, B. P., Schäfer, J., Rameseder, J., Wong, C.-H., Deutsch, E. W., Brusniak, M.-Y., et al. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800032-mcp200 · Cited by 204
“It has been demonstrated before that MRM can be likewise used to quantify peptides (4) or specifically target potential phosphorylation sites (34, 35).”
BackgroundMethodAbbatiello, S. E., Mani, D. R., Keshishian, H., & Carr, S. A. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.138420 · Cited by 198
A Human Proteome Detection and Quantitation Project
Anderson, N. L., Anderson, N. G., Pearson, T. W., Borchers, C. H., Paulovich, A. G., Patterson, S. D., Gillette, M., Aebersold, R., & Carr, S. A. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r800015-mcp200 · Cited by 200
Relative and Absolute Quantitation in Mass Spectrometry–Based Proteomics
Ankney, J. A., Muneer, A., & Chen, X. (2018) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061516-045357 · Cited by 183
Schleich, K., Warnken, U., Fricker, N., Öztürk, S., Richter, P., Kammerer, K., Schnölzer, M., Krammer, P. H., & Lavrik, I. N. (2012) · Molecular Cell · doi:10.1016/j.molcel.2012.05.006 · Cited by 198
“Absolute quantitative protein MS, termed AQUA, is achieved by parallel analysis of proteotypic analyte and isotopically labeled synthetic peptide standards (Gerber et al., 2003).”
MethodIsoelectric focusing technology quantifies protein signaling in 25 cells
O'Neill, R. A., Bhamidipati, A., Bi, X., Deb-Basu, D., Cahill, L., Ferrante, J., Gentalen, E., Glazer, M., Gossett, J., Hacker, K., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607973103 · Cited by 194
Kettenbach, A. N., Rush, J., & Gerber, S. A. (2011) · Nature Protocols · doi:10.1038/nprot.2010.196 · Cited by 176
“To this end, targeted quantification strategies such as AQU”
Self-citationDeciphering post‐translational modification codes
Lothrop, A. P., Torres, M. P., & Fuchs, S. M. (2013) · FEBS Letters · doi:10.1016/j.febslet.2013.01.047 · Cited by 180
Cima, I., Schiess, R., Wild, P., Kaelin, M., Schüffler, P., Lange, V., Picotti, P., Ossola, R., Templeton, A., Schubert, O., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1013699108 · Cited by 189
PhosphoPep—a phosphoproteome resource for systems biology research in Drosophila Kc167 cells
Bodenmiller, B., Malmstrom, J., Gerrits, B., Campbell, D., Lam, H., Schmidt, A., Rinner, O., Mueller, L. N., Shannon, P. T., Pedrioli, P. G., et al. (2007) · Molecular Systems Biology · doi:10.1038/msb4100182 · Cited by 187
“In a typical experiment of this type, the known phosphorylation sites of a protein or set of proteins are detected and quanti-fied in extracts representing different cellular conditions via targeted mass spectrometry experiments such as MRM (Gerber et al , 2003; Domon and Aebersold, 2006; Picotti et al , 2007; Stahl-Ze…”
BackgroundInfluentialFortin, T., Salvador, A., Charrier, J. P., Lenz, C., Lacoux, X., Morla, A., Choquet-Kastylevsky, G., & Lemoine, J. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800238-mcp200 · Cited by 177
“synthetic stable isotope-labeled isotopomer (2).”
MethodKümper, S., Mardakheh, F. K., McCarthy, A., Yeo, M., Stamp, G. W., Paul, A., Worboys, J., Sadok, A., Jørgensen, C., Guichard, S., et al. (2016) · eLife · doi:10.7554/elife.12203 · Cited by 186
“DOI: 10.7554/eLife.12203 18 of 24 Absolute protein level quantitation by selected reaction monitoring A previously reported approach for absolute quantitation of proteins (AQUA) based on standard stable isotope labelled peptides was used (Gerber et al., 2003).”
InfluentialProteolytic 18O‐labeling strategies for quantitative proteomics
Miyagi, M., & Rao, K. C. S. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20116 · Cited by 180
“Absolute quantification of proteins can be done by using isotopically labeled synthetic peptides and mass spectrometry (Gerber et al., 2003); however, this goal requires foreknowledge of the target proteins and preparation of isotopically-labeled synthetic peptides for each of the target proteins.”
BackgroundProteomics technologies for the global identification and quantification of proteins
Brewis, I. A., & Brennan, P. (2010) · Advances in Protein Chemistry and Structural Biology · doi:10.1016/b978-0-12-381264-3.00001-1 · Cited by 171
“This peptide is spiked into the analyte mixture at a known concentration and the ratio of the test peptide to the heavy labeled standard can be used to calculate the concentration of the peptide and hence the protein from which it is derived (Gerber et al., 2003).”
BackgroundGlobal proteomic assessment of the classical protein-tyrosine phosphatome and “Redoxome”
Karisch, R., Fernandez, M., Taylor, P., Virtanen, C., St-Germain, J. R., Jin, L. L., Harris, I. S., Mori, J., Mak, T. W., Senis, Y. A., et al. (2011) · Cell · doi:10.1016/j.cell.2011.07.020 · Cited by 179
“We asked if, by combining qPTPome with absolute quantification (AQUA) (Gerber et al., 2003), the absolute amount of a PTP could be determined (Figure S1).”
Pichler, P., Köcher, T., Holzmann, J., Mazanek, M., Taus, T., Ammerer, G., & Mechtler, K. (2010) · Analytical Chemistry · doi:10.1021/ac100890k · Cited by 175
Increased Selectivity, Analytical Precision, and Throughput in Targeted Proteomics
Kiyonami, R., Schoen, A., Prakash, A., Peterman, S., Zabrouskov, V., Picotti, P., Aebersold, R., Huhmer, A., & Domon, B. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002931 · Cited by 177
“Using isotopic labeled counterparts of the targeted analytes is a common way to confirm the target peptide identity [8,9].”
BackgroundAckermann, B. L., & Berna, M. J. (2007) · Expert Review of Proteomics · doi:10.1586/14789450.4.2.175 · Cited by 179
Perspectives of targeted mass spectrometry for protein biomarker verification
Hüttenhain, R., Malmström, J., Picotti, P., & Aebersold, R. (2009) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.09.014 · Cited by 174
“So far, the most accurate quantification using SRM is achieved by the addition of isotope-labeled reference peptides to the plasma samples at a known concentration and by simultaneously monitoring the transitions for the endogenous and the reference peptides [51,52].”
MethodDeSouza, L. V., Taylor, A. M., Li, W., Minkoff, M. S., Romaschin, A. D., Colgan, T. J., & Siu, K. W. M. (2008) · Journal of Proteome Research · doi:10.1021/pr800312m · Cited by 172
Triple Quad ICPMS (ICPQQQ) as a New Tool for Absolute Quantitative Proteomics and Phosphoproteomics
Fernández, S. D., Sugishama, N., Encinar, J. R., & Sanz-Medel, A. (2012) · Analytical Chemistry · doi:10.1021/ac3009516 · Cited by 173
Quantitative Mass Spectrometry-Based Proteomics: An Overview
Nikolov, M., Schmidt, C., & Urlaub, H. (2012) · Methods in Molecular Biology · doi:10.1007/978-1-61779-885-6_7 · Cited by 167
Shao, B., Pennathur, S., & Heinecke, J. W. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.337345 · Cited by 170
“SRM—Samples were analyzed by nano-LC-MS/MS on a Thermo TSQ Quantum Access coupled to a Waters nanoACQUITY UltraPerformance liquid chromatography (nano-LC) system.”
BackgroundMethodInfluentialIndirect inhibition of 26S proteasome activity in a cellular model of Huntington’s disease
Hipp, M. S., Patel, C. N., Bersuker, K., Riley, B. E., Kaiser, S. E., Shaler, T. A., Brandeis, M., & Kopito, R. R. (2012) · Journal of Cell Biology · doi:10.1083/jcb.201110093 · Cited by 169
Mutant proteins as cancer-specific biomarkers
Wang, Q., Chaerkady, R., Wu, J., Hwang, H. J., Papadopoulos, N., Kopelovich, L., Maitra, A., Matthaei, H., Eshleman, J. R., Hruban, R. H., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1019203108 · Cited by 168
“Heavy isotope-labeled synthetic peptides can serve as internal controls for such experiments, increasing the confidence of identification and facilitating absolute quantification (9,30, 31).”
BackgroundLC–MS/MS for protein and peptide quantification in clinical chemistry
Rauh, M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.09.030 · Cited by 171
Effects of Modified Digestion Schemes on the Identification of Proteins from Complex Mixtures
Klammer, A. A., & MacCoss, M. J. (2006) · Journal of Proteome Research · doi:10.1021/pr050315j · Cited by 164
Zeiler, M., Straube, W. L., Lundberg, E., Uhlen, M., & Mann, M. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.009613 · Cited by 168
“These peptides are very problematic for peptide standard based methods such as AQUA, but in our measurements very similar ratios were measured for such peptides.”
InfluentialGenerating and navigating proteome maps using mass spectrometry
Ahrens, C. H., Brunner, E., Qeli, E., Basler, K., & Aebersold, R. (2010) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2973 · Cited by 168
“Navigating a (complete) proteome map with or without prior information, by the methods described above, can be combined with the well-known quantitative proteomic concepts based on stable isotope labelling to determine absolute or relative quantification between sample”
MethodPeptide and protein imaging mass spectrometry in cancer research
McDonnell, L. A., Corthals, G. L., Willems, S. M., van Remoortere, A., van Zeijl, R. J. M., & Deelder, A. M. (2010) · Journal of Proteomics · doi:10.1016/j.jprot.2010.05.007 · Cited by 161
“When combined with isotopically labeled peptides for absolute protein quantitation [100] this strategy can be used to generate specific MS assays for 10's to 100's of proteins, enabling protein detection and quantification in practically any sample type.”
MethodProteomic Analyses using an Accurate Mass and time Tag Strategy
Paša-Tolić, L., Masselon, C., Barry, R. C., Shen, Y., & Smith, R. D. (2004) · BioTechniques · doi:10.2144/04374rv01 · Cited by 163
Current Status and Advances in Quantitative Proteomic Mass Spectrometry
Wasinger, V. C., Zeng, M., & Yau, Y. Y. (2013) · International Journal of Proteomics · doi:10.1155/2013/180605 · Cited by 190
Personalized Proteomics: The Future of Precision Medicine
Duarte, T. T., & Spencer, C. T. (2016) · Proteomes · doi:10.3390/proteomes4040029 · Cited by 175
“Comparative studies between Hi3 and AQUA have shown that a single labeled internal standard is sufficient for global protein quantitation [34,49].”
Deubiquitinase USP37 Is Activated by CDK2 to Antagonize APCCDH1 and Promote S Phase Entry
Huang, X., Summers, M. K., Pham, V. C., Lill, J. R., Liu, J., Lee, G., Kirkpatrick, D. S., Jackson, P. K., Fang, G., & Dixit, V. M. (2011) · Molecular Cell · doi:10.1016/j.molcel.2011.03.027 · Cited by 175
The emerging role of ICP-MS in proteomic analysis
Bettmer, J., Montes‐Bayón, M., Encinar, J. R., Fernández‐Sánchez, M. L., de la Campa, M. D. R. F., & Sanz‐Medel, A. (2009) · Journal of Proteomics · doi:10.1016/j.jprot.2009.05.003 · Cited by 162
Riley, B. E., Kaiser, S. E., Shaler, T. A., Ng, A. C. Y., Hara, T., Hipp, M. S., Lage, K., Xavier, R. J., Ryu, K.-Y., Taguchi, K., et al. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201005012 · Cited by 161
Proteomics Analysis of Human Coronary Atherosclerotic Plaque
Bagnato, C., Thumar, J., Mayya, V., Hwang, S.-I., Zebroski, H., Claffey, K. P., Haudenschild, C., Eng, J. K., Lundgren, D. H., & Han, D. K. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600259-mcp200 · Cited by 161
“Detection and Quantification of Stromal Cell-derived Factor 1 (SDF1- ) and Growth Factors in Human Atherosclerotic Coronary Artery Samples SDF1- and growth factors in the atherosclerotic human coronary arteries were detected and quantified by using a technique termed AQUA (11).”
MethodInfluentialPlasma Membrane Proteomics and Its Application in Clinical Cancer Biomarker Discovery
Leth‐Larsen, R., Lund, R. R., & Ditzel, H. J. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r900006-mcp200 · Cited by 167
“AQUA has been shown to be useful for quantification of both proteins and post-translational modifications (158).”
MethodInvestigating the Quantitative Nature of MALDI-TOF MS
Szaéjli, E., Feheér, T., & Medzihradszky, K. F. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800108-mcp200 · Cited by 160
“(AQUA) ( 43 ). iTRAQ labeling is unique in this list because the differently labeled components yield the same nominal masses, and thus the quantitation can be accomplished only from MS/MS data.”
BackgroundThe importance of the digest: Proteolysis and absolute quantification in proteomics
Brownridge, P., & Beynon, R. J. (2011) · Methods · doi:10.1016/j.ymeth.2011.05.005 · Cited by 173
Integration of Metabolomic and Proteomic Phenotypes
Wienkoop, S., Morgenthal, K., Wolschin, F., Scholz, M., Selbig, J., & Weckwerth, W. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700273-mcp200 · Cited by 155
“However, for a detailed analysis of the interaction between metabolic enzymes and their corresponding metabolites, targeted approaches are much more feasible (81–84).”
BackgroundRivers, J., Simpson, D. M., Robertson, D. H. L., Gaskell, S. J., & Beynon, R. J. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600456-mcp200 · Cited by 152
From coarse to fine: the absolute Escherichia coli proteome under diverse growth conditions
Mori, M., Zhang, Z., Banaei‐Esfahani, A., Lalanne, J., Okano, H., Collins, B. C., Schmidt, A., Schubert, O. T., Lee, D., Li, G., et al. (2021) · Molecular Systems Biology · doi:10.15252/msb.20209536 · Cited by 149
“These absolute protein mass fractions were evaluated against a set of 29 proteins whose absolute protein abundances had been measured with one representative stable isotope-labeled synthetic peptide per protein (AQUA peptides (Gerber et al, 2003); Dataset EV7).”
Holland, A. J., Fachinetti, D., Zhu, Q., Bauer, M., Verma, I. M., Nigg, E. A., & Cleveland, D. W. (2012) · Genes & Development · doi:10.1101/gad.207027.112 · Cited by 157
“Since only a portion of the total Plk4 pool is likely to be associated with the centrosome at a given time, we determined the total number of Plk4 molecules per cell using protein absolute quantification (AQUA) mass spectrometry (Gerber et al. 2003).”
MethodStable isotopic labeling in proteomics
Gevaert, K., Impens, F., Ghesquière, B., Damme, P. V., Lambrechts, A., & Vandekerckhove, J. (2008) · Proteomics · doi:10.1002/pmic.200800421 · Cited by 91
Köcher, T., Pichler, P., Schutzbier, M., Stingl, C., Kaul, A., Teucher, N., Hasenfuss, G., Penninger, J. M., & Mechtler, K. (2009) · Journal of Proteome Research · doi:10.1021/pr900451u · Cited by 152
Ytterberg, A. J., Joshua, V., Reynisdottir, G., Tarasova, N. K., Rutishauser, D., Ossipova, E., Hensvold, A. H., Eklúnd, A., Sköld, C. M., Grünewald, J., et al. (2014) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2013-204912 · Cited by 154
Proteomics meets the scientific method
Picotti, P., Bodenmiller, B., & Aebersold, R. H. (2012) · Nature Methods · doi:10.1038/nmeth.2291 · Cited by 176
Quantitative interaction proteomics using mass spectrometry
Wepf, A., Glatter, T., Schmidt, A., Aebersold, R. H., & Gstaiger, M. (2009) · Nature Methods · doi:10.1038/nmeth.1302 · Cited by 158
Standardization approaches in absolute quantitative proteomics with mass spectrometry
Calderón‐Celis, F., Encinar, J. R., & Sanz‐Medel, A. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21542 · Cited by 145
“In the case of stable-isotope enriched peptide standards, they can be generated by using the corresponding isotope labeled amino acids, usually enriched in the C-terminal in Lys or Arg, with (15)N and (13)C.(107)”
BackgroundMethodApplication of Mass Spectrometry in Proteomics
Guerrera, I. C., & Kleiner, O. (2005) · Bioscience Reports · doi:10.1007/s10540-005-2849-x · Cited by 191
“Absolute quantitation of modified proteins and peptides has also been done using the previously mentioned AQUA method [ 78 ].”
BackgroundMethodQuantifying Ubiquitin Signaling
Ordureau, A., Münch, C., & Harper, J. W. (2015) · Molecular Cell · doi:10.1016/j.molcel.2015.02.020 · Cited by 149
“…an in vitro sample (Barr et al., 1996), but has been used more recently to determine the stoichiometry of multiple proteins within protein complexes purified from cells as well as the stoichiometry of PTMs in individual proteins (Bennett et al., 2010; Gerber et al., 2003; Kirkpatrick et al., 2005).”
Fortin, T., Salvador, A., Charrier, J. P., Lenz, C., Bettsworth, F., Lacoux, X., Choquet-Kastylevsky, G., & Lemoine, J. (2009) · Analytical Chemistry · doi:10.1021/ac901447h · Cited by 140
Analysis of acetylation stoichiometry suggests that SIRT 3 repairs nonenzymatic acetylation lesions
Weinert, B. T., Moustafa, T., Iesmantavicius, V., Zechner, R., & Choudhary, C. (2015) · The EMBO Journal · doi:10.15252/embj.201591271 · Cited by 151
“In order to directly validate our stoichiometry estimates, we devised a spike-in absolute quantification (AQUA) approach using heavy-isotope-labeled peptide standards (AQUA peptides) (Gerber et al , 2003).”
Analysis of protein phosphorylation on a proteome‐scale
Collins, M. O., Yu, L., & Choudhary, J. S. (2007) · PROTEOMICS · doi:10.1002/pmic.200700145 · Cited by 170
How specific is my SRM?: The issue of precursor and product ion redundancy
Sherman, J., McKay, M. J., Ashman, K., & Molloy, M. P. (2009) · PROTEOMICS · doi:10.1002/pmic.200800577 · Cited by 144
“The proteomic research community is enthusiastically embracing selected reaction monitoring (SRM) MS methods for targeted quantitative proteomic analysis [1–14].”
MethodA Metal-coded Affinity Tag Approach to Quantitative Proteomics
Ahrends, R., Pieper, S., Kühn, A., Weisshoff, H., Hamester, M., Lindemann, T., Scheler, C., Lehmann, K., Taubner, K., & Linscheid, M. W. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700152-mcp200 · Cited by 150
“However, only relative changes can be monitored, and currently, with a few exceptions such as the absolute quantification (AQUA) method (8) or QCAT (9), no labeling techniques are available to determine accurate amounts particularly of whole proteins.”
MethodPhosphoprotein analysis: from proteins to proteomes.
Delom, F., & Chevet, É. (2006) · Proteome Science · doi:10.1186/1477-5956-4-15 · Cited by 182
“The internal standard is a chemically synthesized heavier version of the phosphopeptide being analyzed, allowing absolute quantitation of phosphorylation levels [100,101].”
Prakash, A., Tomazela, D. M., Frewen, B., MacLean, B., Merrihew, G., Peterman, S., & MacCoss, M. J. (2009) · Journal of Proteome Research · doi:10.1021/pr801028b · Cited by 147
Improved Quantitative Mass Spectrometry Methods for Characterizing Complex Ubiquitin Signals
Phu, L., Izrael-Tomasevic, A., Matsumoto, M. L., Bustos, D., Dynek, J. N., Fedorova, A. V., Bakalarski, C. E., Arnott, D., Deshayes, K., Dixit, V. M., et al. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.003756 · Cited by 145
“Each heavy peptide had a single incorporated residue enriched in (13)C/(15)N, and peptide concentrations were determined by amino acid analysis as described previously (36).”
MethodProtein Significance Analysis in Selected Reaction Monitoring (SRM) Measurements
Chang, C.-Y., Picotti, P., Hüttenhain, R., Heinzelmann-Schwarz, V., Jovanovic, M., Aebersold, R., & Vitek, O. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.014662 · Cited by 144
“Heavy isotope-labeled reference peptides (20) were spiked into the samples as internal references, and up to three transitions were measured for each endogenous and heavy-labeled peptide.”
MethodInfluential
Metadata
- Authors
- Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P.
- Affiliations
- Harvard University (US)
- Department of Cell Biology, Harvard Medical School, Boston, MA 02115; and Cell Signaling Technology, Inc., Beverly, MA 01915
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-05-27
- Volume
- 100
- Issue
- 12
- Pages
- 6940-6945
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC165809
- OpenAlex
- W2068481474
- Cited by
- 1,733
- References
- 16
- Citations by year
- 2026: 17 · 2025: 23 · 2024: 23 · 2023: 34 · 2022: 36 · 2021: 34 · 2020: 44 · 2019: 62 · 2018: 56 · 2017: 68 · 2016: 78 · 2015: 94 · 2014: 117 · 2013: 136 · 2012: 159
- FWCI
- 24.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- ERef Bayreuth (University of Bayreuth) (submittedVersion)
- Funders
- National Human Genome Research Institute (HG000 41, T32HG000041, K22HG000041)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ubiquitin and proteasome pathways
- Keywords
- absolute protein quantification, Aqua, isotope-labeled internal standards, post-translational modification, phosphoproteins, multiple reaction monitoring, tandem mass spectrometry, separase, gene silencing, yeast proteome, kinase identification, in vitro kinase assay
- MeSH terms
- Amino Acid Sequence, Animals, Binding Sites, HeLa Cells, Histone Deacetylases, Horses, Humans, Molecular Sequence Data, Myoglobin, Endopeptidases, Phosphoproteins, Phosphorylation, Protein Kinases, Proteins, Mass Spectrometry, Cell Cycle Proteins, Saccharomyces cerevisiae Proteins, Sirtuins, Silent Information Regulator Proteins, Saccharomyces cerevisiae, Sirtuin 2, Separase, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.