Absolute quantification of proteins and phosphoproteins from cell lysates by tandem MS
Open accessThe DOI matches its Crossref record; 15 of the 16 references it cites were found in a registry or an index.
Abstract
A need exists for technologies that permit the direct quantification of differences in protein and posttranslationally modified protein expression levels. Here we present a strategy for the absolute quantification (termed AQUA) of proteins and their modification states. Peptides are synthesized with incorporated stable isotopes as ideal internal standards to mimic native peptides formed by proteolysis. These synthetic peptides can also be prepared with covalent modifications (e.g., phosphorylation, methylation, acetylation, etc.) that are chemically identical to naturally occurring posttranslational modifications. Such AQUA internal standard peptides are then used to precisely and quantitatively measure the absolute levels of proteins and posttranslationally modified proteins after proteolysis by using a selected reaction monitoring analysis in a tandem mass spectrometer. In the present work, the AQUA strategy was used to ( i ) quantify low abundance yeast proteins involved in gene silencing, ( ii ) quantitatively determine the cell cycle-dependent phosphorylation of Ser-1126 of human separase protein, and ( iii ) identify kinases capable of phosphorylating Ser-1501 of separase in an in vitro kinase assay. The methods described here represent focused, alternative approaches for studying the dynamically changing proteome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In contrast to similar methods using labeled peptides as standards, such as AQUA peptides (Gerber et al, 2003), the protein fragments are digested simultaneously together with the target protein, which minimizes errors arising during sample preparation, such as the effect of incomplete trypsin digestion or sample loss prior addition of standard.”
From Gene‐specific correlation of RNA and protein levels in human cells and tissues (2016) · cites this paper as Gerber et al, 2003
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High resolution two-dimensional electrophoresis of proteins.
O'Farrell, P. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41496-8 · Cited by 19,246
Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide Gels
Shevchenko, A., Wilm, M., Vorm, O., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac950914h · Cited by 8,995
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Self-citationCorrelation between Protein and mRNA Abundance in Yeast
Gygi, S. P., Rochon, Y., Franza, B. R., & Aebersold, R. (1999) · Molecular and Cellular Biology · doi:10.1128/mcb.19.3.1720 · Cited by 3,819
Self-citationPeng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647
Self-citationEvaluation of two-dimensional gel electrophoresis-based proteome analysis technology
Gygi, S. P., Corthals, G. L., Zhang, Y., Rochon, Y., & Aebersold, R. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.160270797 · Cited by 1,319
Self-citationA proteomic view of the Plasmodium falciparum life cycle
Florens, L., Washburn, M. P., Raine, J. D., Anthony, R. M., Grainger, M., Haynes, J. D., Moch, J. K., Muster, N., Sacci, J. B., Tabb, D. L., et al. (2002) · Nature · doi:10.1038/nature01107 · Cited by 1,308
Accurate quantitation of protein expression and site-specific phosphorylation
Oda, Y., Huang, K., Cross, F. R., Cowburn, D., & Chait, B. T. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.12.6591 · Cited by 1,006
Analysis of the Plasmodium falciparum proteome by high-accuracy mass spectrometry
Lasonder, E., Ishihama, Y., Andersen, J. S., Vermunt, A. M. W., Pain, A., Sauerwein, R. W., Eling, W. M. C., Hall, N., Waters, A. P., Stunnenberg, H. G., et al. (2002) · Nature · doi:10.1038/nature01111 · Cited by 652
Research works printed but not linked: 1
- Barnidge, D. R., Dratz, E. A., Martin, T., Bonilla, L. E., Moran, L. B. & Lindall, A. (2003) Anal. Chem. 75, 445–451. [DOI] [PubMed] [Google Scholar] · doi:10.1021/ac026154
Cited by
Items 601–700 of 1,002
A Thermal Mechanism of Ion Formation in MALDI
Bae, Y. J., & Kim, M. S. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-081413-024102 · Cited by 46
Percy, A. J., Parker, C. E., & Borchers, C. H. (2013) · Bioanalysis · doi:10.4155/bio.13.245 · Cited by 47
Dayon, L., Turck, N., Kienle, S., Schulz‐Knappe, P., Hochstrasser, D. F., Scherl, A., & Sanchez, J. (2010) · Analytical Chemistry · doi:10.1021/ac901854k · Cited by 50
Hwang, J., Walczak, C. P., Shaler, T. A., Olzmann, J. A., Zhang, L., Elias, J. E., & Kopito, R. R. (2017) · Journal of Biological Chemistry · doi:10.1074/jbc.m117.785055 · Cited by 48
“Stoichiometry of Hrd1 complexes determined by AQUA-MS.”
MethodInfluentialTargeted proteomics for validation of biomarkers in clinical samples
Ye, X., Blonder, J., & Veenstra, T. D. (2008) · Briefings in Functional Genomics and Proteomics · doi:10.1093/bfgp/eln050 · Cited by 54
“that most laboratories use for MS-based biomarker validation [12, 13].”
Chemical tools for activity-based proteomics
Hagenstein, M. C., & Sewald, N. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.12.005 · Cited by 52
Holzmann, J., Pichler, P., Madalinski, M., Kurzbauer, R., & Mechtler, K. (2009) · Analytical Chemistry · doi:10.1021/ac902286m · Cited by 45
Celius, T., Pansoy, A., Matthews, J. B., Okey, A. B., Henderson, M. C., Krueger, S. K., & Williams, D. E. (2010) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2010.05.018 · Cited by 45
“AQUA mass spectrometry for mouse FMO3 protein quantification AQUA (absolute quantification) mass spectrometry quantifies proteins by tandem mass spectrometry and MRM (multiple reaction monitoring) (Gerber et al., 2003).”
MethodAbsolute Quantification of Selected Proteins in the Human Osteoarthritic Secretome
Peffers, M. J., Beynon, R. J., & Clegg, P. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms141020658 · Cited by 49
“Stable isotope labelled quantification includes the use of chemically synthesized peptide standards known as AQUA peptides [25] and QconCAT [26].”
MethodA requirement for wild-type Ras isoforms in mutant KRas-driven signalling and transformation
Bentley, C., Jurinka, S. S., Kljavin, N. M., Vartanian, S., Ramani, S. R., Gonzalez, L. C., Yu, K., Modrusan, Z., Du, P., Bourgon, R., et al. (2013) · Biochemical Journal · doi:10.1042/bj20121578 · Cited by 44
Unique Ion Signature Mass Spectrometry, a Deterministic Method to Assign Peptide Identity
Sherman, J., McKay, M. J., Ashman, K., & Molloy, M. P. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800512-mcp200 · Cited by 44
Shuford, C. M., Li, Q., Sun, Y., Chen, H.-C., Wang, J., Shi, R., Sederoff, R. R., Chiang, V. L., & Muddiman, D. C. (2012) · Journal of Proteome Research · doi:10.1021/pr300205a · Cited by 53
Metal–organic framework-based affinity materials in proteomics
Saeed, A., Hussain, D., Saleem, S., Mehdi, S., Javeed, R., Jabeen, F., & Haq, M. N. U. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01610-x · Cited by 45
Chen, Y., Gruidl, M., Remily-Wood, E. R., Liu, R. Z., Eschrich, S. A., Lloyd, M. C., Nasir, A., Bui, M. M., Huang, E. H., Shibata, D., et al. (2010) · Journal of Proteome Research · doi:10.1021/pr1005197 · Cited by 50
Matic, I., Jaffray, E. G., Oxenham, S. K., Groves, M. J., Barratt, C. L. R., Tauro, S., Stanley-Wall, N. R., & Hay, R. T. (2011) · Journal of Proteome Research · doi:10.1021/pr2004715 · Cited by 44
Gianazza, E., Tremoli, E., & Banfi, C. (2014) · Expert Review of Proteomics · doi:10.1586/14789450.2014.947966 · Cited by 48
“The most commonly used approach for a SRM/MRM absolute quantitation analysis involves the use of stable isotopelabeled internal standards (absolute quantification [AQUA] peptides), that are chemically identical to the native peptides and are added to the sample at a known concentration (TABLE 1) [44].”
MethodCharacterizing phosphoproteins and phosphoproteomes using mass spectrometry
Goshe, M. B. (2006) · Briefings in Functional Genomics and Proteomics · doi:10.1093/bfgp/eli007 · Cited by 45
“A method of isotope dilution using synthetic isotope-coded peptides as internal standards for absolute quantification of proteins by MS has been developed and is referred to as AQUA (absolute quantification) [48].”
Nanavati, D. M., Guček, M., Milne, J. L. S., Subramaniam, S., & Markey, S. P. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700345-mcp200 · Cited by 45
“proteolysis of proteins of interest (7).”
Absolute protein quantification by LC-ICP-MS using MeCAT peptide labeling
Esteban‐Fernández, D., Scheler, C., & Linscheid, M. W. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5104-2 · Cited by 44
“However, the chemical labeling is the most extended strategy and methodologies as ICAT (isotopecoded affinity tag) [19], ICPL (isotope-coded protein label) [20], iTRAQ (isobaric tag for relative and absolute quantification) [21] or PROTEIN-AQUA (protein absolute quantification) [22] are capable to quantify in relative…”
MethodAssessing normalization methods in mass spectrometry-based proteome profiling of clinical samples
Dubois, E., Galindo, A. N., Dayon, L., & Cominetti, O. (2022) · Biosystems · doi:10.1016/j.biosystems.2022.104661 · Cited by 47
Percy, A. J., Chambers, A. G., Parker, C. E., & Borchers, C. H. (2013) · Methods in molecular biology · doi:10.1007/978-1-62703-405-0_13 · Cited by 46
The Staphylococcus aureus proteome
Otto, A., van Dijl, J. M., Hecker, M., & Becher, D. (2013) · International Journal of Medical Microbiology · doi:10.1016/j.ijmm.2013.11.007 · Cited by 51
Curran, T. G., Zhang, Y., Ma, D. J., Sarkaria, J. N., & White, F. M. (2015) · Nature Communications · doi:10.1038/ncomms6924 · Cited by 44
Peptide and Protein Drug Analysis by MS: Challenges and Opportunities for The Discovery Environment
Campbell, J. L., & Blanc, J. Y. L. (2011) · Bioanalysis · doi:10.4155/bio.11.31 · Cited by 44
Higher-energy Collision-activated Dissociation Without a Dedicated Collision Cell
McAlister, G. C., Phanstiel, D. H., Brumbaugh, J., Westphall, M. S., & Coon, J. J. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.009456 · Cited by 43
“uct transitions from upstream discovery data (12, 13).”
BackgroundMass Spectrometry in Systems Biology
Dunn, W. B. (2011) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/b978-0-12-385118-5.00002-5 · Cited by 55
Interplay between the bacterial protein deacetylase CobB and the second messenger c‐di‐GMP
Xu, Z., Zhang, H., Zhang, X., Jiang, H., Liu, C., Wu, F., Qian, L., Hao, B., Czajkowsky, D. M., Guo, S., et al. (2018) · The EMBO Journal · doi:10.15252/embj.2018100948 · Cited by 46
“In order to better characterize the endogenous stoichiometric extent of DgcZ K4 acetylation, we used the absolute quantification (AQUA) method (Gerber et al , 2003; Weinert et al , 2015) to quantify the level of the K4-acetylated peptide.”
The Absolute Quantification Strategy
Gerber, S. A., Kettenbach, A. N., Rush, A. J., & Gygi, S. P. (2007) · Methods in molecular biology · doi:10.1007/978-1-59745-255-7_5 · Cited by 44
Self-citationAnalyzing the Cryptome: Uncovering Secret Sequences
Samir, P., & Link, A. J. (2011) · The AAPS Journal · doi:10.1208/s12248-011-9252-2 · Cited by 155
“identify and/or quantify peptide(s) and can be utilized for quantitating cryptide(s) that is known a priori (49).”
BackgroundDefining Synphenotype Groups in Xenopus tropicalis by Use of Antisense Morpholino Oligonucleotides
Rana, A. A., Collart, C., Gilchrist, M. J., & Smith, J. C. (2006) · PLoS Genetics · doi:10.1371/journal.pgen.0020193 · Cited by 48
“Although in this paper we have not been able to address the efficacy of individual MOs with respect to their ability to depress levels of the targeted protein, this may be possible in the future by use of techniques such as iTRAQ [62] or AQUA [63].”
MethodEvaluation of minimal 13C-labelling for stable isotope dilution in organic analysis
González‐Antuña, A., Rodríguez‐González, P., Centineo, G., & Alonso, J. I. G. (2010) · The Analyst · doi:10.1039/b924432h · Cited by 44
Broad range of missense error frequencies in cellular proteins
Garofalo, R., Wohlgemuth, I., Pearson, M., Lenz, C., Urlaub, H., & Rodnina, M. V. (2019) · Nucleic Acids Research · doi:10.1093/nar/gky1319 · Cited by 49
“First, the amount of correct peptides is determined by selected reaction monitoring (SRM, reviewed in (31)) using four isotopically labeled Absolute QUAntification (AQUA) peptides of known concentration (45) (Figure 2B).”
MethodTargeted proteomics on its way to discovery
Mendes, M. L., & Dittmar, G. (2022) · PROTEOMICS · doi:10.1002/pmic.202100330 · Cited by 43
“Because the concentration of the heavy peptide is previously known, it is possible to determine the absolute concentration of the light counterpart by integrating the areas under the curve [7].”
BackgroundCutillas, P. R., Khwaja, A., Graupera, M., Pearce, W. P., Gharbi, S., Waterfield, M. D., & Vanhaesebroeck, B. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602101103 · Cited by 43
New types of experimental data shape the use of enzyme kinetics for dynamic network modeling
Tummler, K., Lubitz, T., Schelker, M., & Klipp, E. (2013) · FEBS Journal · doi:10.1111/febs.12525 · Cited by 57
“Absolute quantification is possible via standard peptides (e.g. chemically synthesized AQUA peptides [73] or QconCAT-derived peptides [74] for multiplexed absolute quantification) or by using various label-free methods [75], and holds the same benefits as for the metabolomic studies.”
MethodShi, T., Fillmore, T. L., Gao, Y., Zhao, R., He, J., Schepmoes, A. A., Nicora, C. D., Wu, C., Chambers, J. L., Moore, R. J., et al. (2013) · Analytical Chemistry · doi:10.1021/ac402105s · Cited by 43
Ji, C., Tschantz, W. R., Pfeifer, N. D., Ullah, M., & Sadagopan, N. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.12.005 · Cited by 44
Protein quantitation using isotope-assisted mass spectrometry.
Kline, K. G., & Sussman, M. (2010) · Annual Review of Biophysics · doi:10.1146/annurev.biophys.093008.131339 · Cited by 40
Absolute Quantification of Histone PTM Marks by MRM-Based LC-MS/MS
Gao, J., Liao, R., Yu, Y., Zhai, H., Wang, Y., Sack, R., Peters, A. H. F. M., Chen, J., Wu, H., Huang, Z., et al. (2014) · Analytical Chemistry · doi:10.1021/ac502333a · Cited by 43
Phenotypic Analysis of Organoids by Proteomics
Gonneaud, A., Asselin, C., Boudreau, F., & Boisvert, F. (2017) · PROTEOMICS · doi:10.1002/pmic.201700023 · Cited by 47
“In contrast to the other quantitative methods, MRM allows absolute quantitation by using isotopically labeled synthetic peptide internal standards, which are designed to be identical to target peptides [45].”
ResultProtein Quantification and Imaging by Surface‐Enhanced Raman Spectroscopy and Similarity Analysis
Shin, H., Oh, S., Kang, D., & Choi, Y. (2020) · Advanced Science · doi:10.1002/advs.201903638 · Cited by 43
Protein identification and expression analysis using mass spectrometry
Kolker, E., Higdon, R., & Hogan, J. M. (2006) · Trends in Microbiology · doi:10.1016/j.tim.2006.03.005 · Cited by 58
Sung, H.-J., Jeon, S., Ahn, J., Seul, K.-J., Kim, J. Y., Lee, J. Y., Yoo, J. S., Lee, S., Kim, H., & Cho, J. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.01.018 · Cited by 42
Rigorous determination of the stoichiometry of protein phosphorylation using mass spectrometry
Johnson, H., Eyers, C. E., Eyers, P. A., Beynon, R. J., & Gaskell, S. J. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.08.009 · Cited by 42
“Alternatively, mass spectrometric experiments can be performed to determine the exact amount of phosphorylated and nonphosphorylated peptides, thereby inferring the stoichiometry of phosphorylation, by addition of known amounts of synthetic stable isotope-labeled analogues of both variants [10, 11].”
BackgroundCharacterization of Cytochrome P450s with Key Roles in Determining Herbicide Selectivity in Maize
Brazier‐Hicks, M., Ortega, S. F., Watson, P., Rougemont, B., Cohn, J., Dale, R. P., Hawkes, T. R., Goldberg-Cavalleri, A., Onkokesung, N., & Edwards, R. (2022) · ACS Omega · doi:10.1021/acsomega.2c01705 · Cited by 45
Tools for exploring the proteomosphere
Shevchenko, A., Vâlcu, C., & Junqueira, M. (2009) · Journal of Proteomics · doi:10.1016/j.jprot.2009.01.012 · Cited by 42
“[63] Gerber SA, Rush J, Stemman O, Kirschner MW, Gygi SP.”
Blackburn, K., & Goshe, M. B. (2008) · Briefings in Functional Genomics and Proteomics · doi:10.1093/bfgp/eln051 · Cited by 48
“With the use of ion traps, these neutral losses can be used to trigger another round of CID of the neutral loss ‘precursor’ using an MS(3) event, which produces peptide backbone sequence specific ions which may be used for a subsequent database searching and phosphopeptide site assignment [31, 62, 63].”
Basic Design of MRM Assays for Peptide Quantification
James, A., & Jørgensen, C. (2010) · Methods in molecular biology · doi:10.1007/978-1-60761-780-8_10 · Cited by 42
Stauber, E. J., Busch, A., Naumann, B., Svatoš, A., & Hippler, M. (2009) · PROTEOMICS · doi:10.1002/pmic.200700620 · Cited by 42
Analysis of biopharmaceutical proteins in biological matrices by LC-MS/MS II. LC-MS/MS analysis
Gérard Hopfgartner, D., Lesur, A., & Varesio, E. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.03.008 · Cited by 41
Vasilj, A., Gentzel, M., Ueberham, E., Gebhardt, R., & Shevchenko, A. (2012) · Journal of Proteome Research · doi:10.1021/pr300147z · Cited by 43
Evaluation of absolute peptide quantitation strategies using selected reaction monitoring
Campbell, J., Rezai, T., Prakash, A., Krastins, B., Dayon, L., Ward, M., Robinson, S., & Lopez, M. (2011) · PROTEOMICS · doi:10.1002/pmic.201000511 · Cited by 40
“Heavy stable isotopes are commonly used to introduce a mass difference into the standards and are either directly incorporated into synthetic absolute quantitation (AQUA) peptides or added as part of a chemical derivatisation step such as tandem mass tag (TMT)-SRM [1, 2].”
BackgroundNew dimensions in the study of protein complexes using quantitative mass spectrometry
Oeljeklaus, S., Meyer, H. E., & Warscheid, B. (2009) · FEBS Letters · doi:10.1016/j.febslet.2009.04.018 · Cited by 41
“This requires the acquisition of absolute quantitative information on their abundance, for example using stable isotope-labeled synthetic standard peptides for absolute quantification (AQUA; [42]) or following dif-”
Ludwig, M. R., Kojima, K., Bowersock, G. J., Chen, D., Jhala, N. C., Buchsbaum, D. J., Grizzle, W. E., Klug, C. A., & Mobley, J. A. (2015) · PROTEOMICS · doi:10.1002/pmic.201500133 · Cited by 41
“For this experiment, we chose to use a medium throughput 3-hour 1D gradient run in triplicate as opposed to a more standard 2D MudPIT analysis in order to increase throughput, while exploring the potential for a more streamlined paralleled validation via an AQUA-based approach for future studies [57].”
MethodChen, Y., Tuan, L.-P., Chen, H., Wei, I.-A., Chou, M., Chen, H., Tyan, Y., & Chen, S. (2014) · Analytical Chemistry · doi:10.1021/ac5033066 · Cited by 42
Croote, D., Braslavsky, I., & Quake, S. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01388 · Cited by 44
Yu, Q., Liu, X., Keller, M. P., Navarrete-Perea, J., Zhang, T., Fu, S., Vaites, L. P., Shuken, S. R., Schmid, E. W., Keele, G. R., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-36269-7 · Cited by 43
Self-citationA Nutrigenomics View of Protein Intake
Chou, C. J., Affolter, M., & Kussmann, M. (2012) · Progress in molecular biology and translational science · doi:10.1016/b978-0-12-398397-8.00003-4 · Cited by 49
Reference Measurement Procedure Development for C-Reactive Protein in Human Serum
Kilpatrick, E. L., & Bunk, D. M. (2009) · Analytical Chemistry · doi:10.1021/ac901597h · Cited by 41
Kubota, K., Yoneyama‐Takazawa, T., & Ichikawa, K. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1842 · Cited by 41
Proteomic methods in nutrition
Kussmann, M., & Affolter, M. (2006) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/01.mco.0000241667.23137.a2 · Cited by 41
Greer, T., Lietz, C. B., Xiang, F., & Li, L. (2014) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-014-1012-y · Cited by 40
“Peptides are used as surrogates representing absolute protein abundance levels and can be quantified at subfemtomole levels [6, 7].”
BackgroundMethodTimm, W., Scherbart, A., Böcker, S., Kohlbacher, O., & Nattkemper, T. W. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-443 · Cited by 43
“Absolute quantification with very high accuracy using label-free methods is possible through the use of reference peptides [7], an example being AQUA (Absolute Quantification of Proteins) [8].”
MethodRecent developments in public proteomic MS repositories and pipelines
Mead, J. A., Bianco, L., & Bessant, C. (2009) · PROTEOMICS · doi:10.1002/pmic.200800553 · Cited by 43
Proteomic analysis of plasma membrane lipid rafts of HL‐60 cells
Yanagida, M., Nakayama, H., Yoshizaki, F., Fujimura, T., Takamori, K., Ogawa, H., & Iwabuchi, K. (2007) · PROTEOMICS · doi:10.1002/pmic.200700056 · Cited by 44
Gene expression and protein abundance: Just how associated are these molecular traits?
Samih, A., Ferreira, M. A. D. M., & Nikoloski, Z. (2025) · Biotechnology Advances · doi:10.1016/j.biotechadv.2025.108720 · Cited by 43
Impact of HDL oxidation by the myeloperoxidase system on sterol efflux by the ABCA1 pathway
Shao, B., & Heinecke, J. W. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.04.001 · Cited by 42
“Therefore, chemical noise is significantly reduced and the signal to noise ratio can be markedly improved [87,88].”
Miliotis, T., Ali, L., Palm, J. E., Lundqvist, A. J., Ahnoff, M., Andersson, T. B., & Hilgendorf, C. (2011) · Drug Metabolism and Disposition · doi:10.1124/dmd.111.040774 · Cited by 39
“The core mass spectrometric technology that has emerged for protein quantification is based on the concept of stable isotope dilution combined with multiple reaction monitoring (MRM) (Gerber et al., 2003; Anderson et al., 2004; Carr and Anderson, 2008).”
MethodProteomic Investigations of Complex I Composition: How to Define a Subunit?
Meyer, E. H. (2012) · Frontiers in Plant Science · doi:10.3389/fpls.2012.00106 · Cited by 39
“Several approaches have been developed to determine the stoichiometry of proteins (Gerber et al., 2003; Hochleitner et al., 2004; Beynon et al., 2005; Nanavati et al., 2008).”
BackgroundRecent advances in phosphoproteomics and application to neurological diseases
Arrington, J. V., Hsu, C.-C., Elder, S. G., & Andy Tao, W. (2017) · The Analyst · doi:10.1039/c7an00985b · Cited by 38
Zimmer, D. M., Schneider, K., Sommer, F., Schroda, M., & Mühlhaus, T. (2018) · Frontiers in Plant Science · doi:10.3389/fpls.2018.01559 · Cited by 53
“After ionization, these pairs can be separated and quantified by mass spectrometry, with the synthetic peptide serving as calibrator (Barnidge et al., 2003; Gerber et al., 2003).”
MethodAbundance of bacterial Type VI secretion system components measured by targeted proteomics
Lin, L., Lezan, E., Schmidt, A., & Basler, M. (2019) · Nature Communications · doi:10.1038/s41467-019-10466-9 · Cited by 39
Lam, M. P. Y., Scruggs, S. B., Kim, T., Zong, C., Lau, E., Wang, D., Ryan, C. M., Faull, K. F., & Ping, P. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.02.014 · Cited by 39
“MRM quantification of phosphorylation was performed by measuring the ion current generated from analyte-specific transitions; this provides specificity and sensitivity as a result of utilizing liquid chromatographic retention time in combination with two selective mass filters of a triple quadrupole mass spectrometer…”
MethodTissue Bioanalysis of Biotherapeutics And Drug Targets to Support Pk/Pd
Neubert, H., Fountain, S. T., King, L., Clark, T. H., Weng, Y., O’Hara, D. M., Li, W., Leung, S. S., RAY, C. A., Palandra, J., et al. (2012) · Bioanalysis · doi:10.4155/bio.12.234 · Cited by 39
Costs of life - Dynamics of the protein inventory of Staphylococcus aureus during anaerobiosis
Zühlke, D., Dörries, K., Bernhardt, J., Maaß, S., Muntel, J., Liebscher, V., Pané‐Farré, J., Riedel, K., Lalk, M., Völker, U., et al. (2016) · Scientific Reports · doi:10.1038/srep28172 · Cited by 44
Analytical methodologies for broad metabolite coverage of exhaled breath condensate
Aksenov, A. A., Zamuruyev, K. O., Pasamontes, A., Brown, J. F., Schivo, M., Foutouhi, S., Weimer, B. C., Kenyon, N. J., & Davis, C. E. (2017) · Journal of Chromatography B · doi:10.1016/j.jchromb.2017.06.038 · Cited by 42
“In addition to offering a tremendous volume of chemical information, MS offers incredible sensitivity down to attomolar levels [25], and selectivity appropriate for chemical species identification.”
BackgroundEbhardt, H. A., Sabidó, E., Hüttenhain, R., Collins, B., & Aebersold, R. (2012) · PROTEOMICS · doi:10.1002/pmic.201100543 · Cited by 38
Quantification of seven apolipoproteins in human plasma by proteotypic peptides using fast LC‐MS/MS
Ceglarek, U., Dittrich, J., Becker, S., Baumann, F., Kortz, L., & Thiery, J. (2013) · PROTEOMICS – Clinical Applications · doi:10.1002/prca.201300034 · Cited by 38
Hakimi, A., Auluck, J., Jones, G. D. D., Ng, L. L., & Jones, D. J. L. (2013) · PROTEOMICS · doi:10.1002/pmic.201200563 · Cited by 38
“Different methods of labeling such as stable isotope labeling by amino acids in cell culture [21], chemically synthesized peptides [22] and isobaric tags for relative and absolute quantification [23] are among the most common methods used for quantitation studies.”
MethodGonzález‐Antuña, A., Rodríguez‐González, P., Ohlendorf, R., Henrion, A., Delatour, V., & Alonso, J. I. G. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.09.005 · Cited by 38
Applications of Mass Spectrometry in Proteomics
Sokolowska, I., Wetie, A. G. N., Woods, A. G., & Darie, C. C. (2013) · Australian Journal of Chemistry · doi:10.1071/ch13137 · Cited by 41
Feteisi, H. A., Achour, B., Barber, J., & Rostami‐Hodjegan, A. (2015) · The AAPS Journal · doi:10.1208/s12248-014-9712-6 · Cited by 40
“Absolute quantification may be done by introducing a defined amount of chemically synthesized standard peptides to the sample prior to LC-MSMS analysis (6) and these peptides are sometimes known as absolute quantification (AQUA) peptides.”
Quantification of the Proteins of the Bacterial Ribosome Using QconCAT Technology
Al‐Majdoub, Z. M., Carroll, K. M., Gaskell, S. J., & Barber, J. (2014) · Journal of Proteome Research · doi:10.1021/pr400667h · Cited by 38
Discussion on common data analysis strategies used in MS‐based proteomics
Matthiesen, R., Azevedo, L., Amorim, A., & Carvalho, A. S. (2011) · PROTEOMICS · doi:10.1002/pmic.201000404 · Cited by 45
“[118] Sherman, J., McKay, M., Ashman, K., Molloy, K., How specific is my SRM?”
MethodInfluentialProteomic tools to decipher microbial community structure and functioning
Arsène‐Ploetze, F., Bertin, P. N., & Carapito, C. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-3898-0 · Cited by 41
“…quantified heavy labeled synthetic standards exist in several alternative forms: purified and quantified synthetic peptides (AQUA peptides, Gerber et al. 2003), concatemers of peptides (QconCAT, Beynon et al. 2005) and standard proteins biochemically identical to natural proteins (PSAQ,…”
BackgroundRemily-Wood, E. R., Benson, K., Baz, R., Chen, Y. A., Hussein, M. A., Hartley-Brown, M. A., Sprung, R. W., Perez, B., Liu, R. Z., Yoder, S., et al. (2014) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201300077 · Cited by 40
Hillered, L., Dahlin, A. P., Clausen, F., Chu, J., Bergquist, J., Hjort, K., Enblad, P., & Lewén, A. (2014) · Frontiers in Neurology · doi:10.3389/fneur.2014.00245 · Cited by 38
“There are several strategies for quantitative MS proteomics (56, 57).”
MethodErratum To: Acetylation dynamics and stoichiometry in Saccharomyces cerevisiae
Weinert, B. T., Iešmantavičius, V., Moustafa, T., Schölz, C., Wagner, S., Magnes, C., Zechner, R., & Choudhary, C. (2015) · Molecular Systems Biology · doi:10.15252/msb.156513 · Cited by 38
Iliuk, A. B., Arrington, J. V., & Tao, W. A. (2014) · Electrophoresis · doi:10.1002/elps.201400153 · Cited by 39
Recombinant Isotope Labeled and Selenium Quantified Proteins for Absolute Protein Quantification
Zinn, N., Winter, D., & Lehmann, W. D. (2010) · Analytical Chemistry · doi:10.1021/ac9025412 · Cited by 44
CZE‐ESI‐MS/MS system for analysis of subnanogram amounts of tryptic digests of a cellular homogenate
Sun, L., Zhu, G., Li, Y., Wojcik, R., Yang, P., & Dovichi, N. J. (2012) · PROTEOMICS · doi:10.1002/pmic.201200100 · Cited by 37
“The use of accurate mass tags or multiple reaction monitoring should provide an order of magnitude improved sensitivity [26, 27].”
MethodMeCAT—new iodoacetamide reagents for metal labeling of proteins and peptides
Schwarz, G., Beck, S., Weller, M. G., & Linscheid, M. W. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5189-7 · Cited by 37
“The only exception to this drawback is AQUA, which enables absolute quantification of proteins and peptides, but requires detailed structural knowledge of the protein, due to the use of isotopically labeled standard peptides [2].”
BackgroundZuberovic, A., Wetterhall, M., Hanrieder, J., & Bergquist, J. (2009) · Electrophoresis · doi:10.1002/elps.200800714 · Cited by 37
Statistical Approach to Protein Quantification
Gerster, S., Kwon, T., Ludwig, C., Matondo, M., Vogel, C., Marcotte, E. M., Aebersold, R., & Bühlmann, P. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.025445 · Cited by 36
“The presented datasets include (i) mixtures with added AQUA peptides (1) used to experimentally quantify a subset of the proteins (see “SRM Experiment on Leptospira interrogans” (36) and “Directed MS Human Data” (42)) and (ii) a human SILAC-labeled proteomics experiment without a known ground truth (see “SILAC-labeled…”
MethodRecent advances in absolute quantification of peptides and proteins using LC-MS
Zhang, S., & Jian, W. (2014) · Reviews in Analytical Chemistry · doi:10.1515/revac-2013-0019 · Cited by 40
“called these peptides “absolute quantification” (AQUA) peptides and used the strategy to quantify phosphorylated proteins in whole-cell lysates (Gerber et al. 2003).”
MethodTrost, M., Bridon, G., Desjardins, M., & Thibault, P. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20297 · Cited by 43
The role of toxicoproteomics in assessing organ specific toxicity
Merrick, B. A., & Witzmann, F. A. (2009) · Proceedings of the Fourth International Symposium on Polarization Phenomena in Nuclear Reactions · doi:10.1007/978-3-7643-8336-7_13 · Cited by 39
“This can be accomplished without stable-isotope labeling or tagging, in any of several ways that include integration of ion chromatogram intensities [32,33], spectral counting [34–37], or selected reaction monitoring (SRM) [38,39].”
BackgroundGeLC-MRM Quantitation of Mutant KRAS Oncoprotein in Complex Biological Samples
Halvey, P. J., Ferrone, C. R., & Liebler, D. C. (2012) · Journal of Proteome Research · doi:10.1021/pr300161j · Cited by 37
Quantification of Proteins Using Peptide Immunoaffinity Enrichment Coupled with Mass Spectrometry
Zhao, L., Whiteaker, J. R., Pope, M. E., Kuhn, E. W., Jackson, A., Anderson, N. L., Pearson, T. W., Carr, S. A., & Paulovich, A. G. (2011) · Journal of Visualized Experiments · doi:10.3791/2812 · Cited by 37
“SRM/MRM-MS is well established for accurate quantitation of small molecules 3, 4 and more recently has been adapted to measure the concentrations of proteins in plasma and cell lysates.(5-7) To achieve quantitation of proteins, these larger molecules are digested to component peptides using an enzyme such as trypsin.”
MethodProteomic analysis of parthenogenetic and in vitro fertilized porcine embryos
Gupta, M. K., Jang, J. M., Jung, J. W., Uhm, S. J., Kim, K. P., & Lee, H. T. (2009) · PROTEOMICS · doi:10.1002/pmic.200800700 · Cited by 38
“LC-MS/MS evaluation of synthetic internal standard peptides (myoglobin and MAP3K) was also performed to obtain qualitative information about peptide retention by reverse-phase chromatography, ionization efficiency and fragmentation via collision-induced dissociation [48, 54].”
Method
Metadata
- Authors
- Gerber, S. A., Rush, J., Stemman, O., Kirschner, M. W., & Gygi, S. P.
- Affiliations
- Harvard University (US)
- Department of Cell Biology, Harvard Medical School, Boston, MA 02115; and Cell Signaling Technology, Inc., Beverly, MA 01915
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2003-05-27
- Volume
- 100
- Issue
- 12
- Pages
- 6940-6945
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC165809
- OpenAlex
- W2068481474
- Cited by
- 1,733
- References
- 16
- Citations by year
- 2026: 17 · 2025: 23 · 2024: 23 · 2023: 34 · 2022: 36 · 2021: 34 · 2020: 44 · 2019: 62 · 2018: 56 · 2017: 68 · 2016: 78 · 2015: 94 · 2014: 117 · 2013: 136 · 2012: 159
- FWCI
- 24.98
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- ERef Bayreuth (University of Bayreuth) (submittedVersion)
- Funders
- National Human Genome Research Institute (HG000 41, T32HG000041, K22HG000041)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ubiquitin and proteasome pathways
- Keywords
- absolute protein quantification, Aqua, isotope-labeled internal standards, post-translational modification, phosphoproteins, multiple reaction monitoring, tandem mass spectrometry, separase, gene silencing, yeast proteome, kinase identification, in vitro kinase assay
- MeSH terms
- Amino Acid Sequence, Animals, Binding Sites, HeLa Cells, Histone Deacetylases, Horses, Humans, Molecular Sequence Data, Myoglobin, Endopeptidases, Phosphoproteins, Phosphorylation, Protein Kinases, Proteins, Mass Spectrometry, Cell Cycle Proteins, Saccharomyces cerevisiae Proteins, Sirtuins, Silent Information Regulator Proteins, Saccharomyces cerevisiae, Sirtuin 2, Separase, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.