The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Self-assembled artificial cilia
Open accessAbstract
Due to their small dimensions, microfluidic devices operate in the low Reynolds number regime. In this case, the hydrodynamics is governed by the viscosity rather than inertia and special elements have to be introduced into the system for mixing and pumping of fluids. Here we report on the realization of an effective pumping device that mimics a ciliated surface and imitates its motion to generate fluid flow. The artificial biomimetic cilia are constructed as long chains of spherical superparamagnetic particles, which self-assemble in an external magnetic field. Magnetic field is also used to actuate the cilia in a simple nonreciprocal manner, resulting in a fluid flow. We prove the concept by measuring the velocity of a cilia-pumped fluid as a function of height above the ciliated surface and investigate the influence of the beating asymmetry on the pumping performance. A numerical simulation was carried out that successfully reproduced the experimentally obtained data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Purcell, E. M. (1977) · American Journal of Physics · doi:10.1119/1.10903 · Cited by 4,360
Microscopic artificial swimmers
Dreyfus, R., Baudry, J., Roper, M. L., Fermigier, M., Stone, H. A., & Bibette, J. (2005) · Nature · doi:10.1038/nature04090 · Cited by 1,853
Variational Treatment of Hydrodynamic Interaction in Polymers
Rotne, J., & Prager, S. (1969) · The Journal of Chemical Physics · doi:10.1063/1.1670977 · Cited by 1,139
Printed artificial cilia from liquid-crystal network actuators modularly driven by light
van Oosten, C. L., Bastiaansen, C. W. M., & Broer, D. J. (2009) · Nature Materials · doi:10.1038/nmat2487 · Cited by 971
A note on the image system for a stokeslet in a no-slip boundary
Blake, J. R. (1971) · Mathematical Proceedings of the Cambridge Philosophical Society · doi:10.1017/s0305004100049902 · Cited by 778
Moving Fluid with Bacterial Carpets
Darnton, N., Turner, L., Breuer, K., & Berg, H. C. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74253-8 · Cited by 376
Magnetically Actuated Nanorod Arrays as Biomimetic Cilia
Evans, E. E., Shields, A. R., Carroll, R. L., Washburn, S., Falvo, M. R., & Superfine, R. (2007) · Nano Letters · doi:10.1021/nl070190c · Cited by 304
Artificial cilia for active micro-fluidic mixing
Toonder, J. D., Bos, F., Broer, D., Filippini, L., Gillies, M., de Goede, J., Mol, T., Reijme, M., Talen, W., Wilderbeek, H., et al. (2008) · Lab on a Chip · doi:10.1039/b717681c · Cited by 296
Hydrodynamic Flow Patterns and Synchronization of Beating Cilia
Vilfan, A., & Jülicher, F. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.058102 · Cited by 234
Self-citationEnergetic considerations of ciliary beating and the advantage of metachronal coordination
Gueron, S., & Levit-Gurevich, K. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.22.12240 · Cited by 232
Cilia internal mechanism and metachronal coordination as the result of hydrodynamical coupling
Gueron, S., Levit-Gurevich, K., Liron, N., & Blum, J. J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.12.6001 · Cited by 227
Fabrication of Bioinspired Actuated Nanostructures with Arbitrary Geometry and Stiffness
Pokroy, B., Epstein, A. K., Persson‐Gulda, M. C. M., & Aizenberg, J. (2009) · Advanced Materials · doi:10.1002/adma.200801432 · Cited by 190
Fluid transport at low Reynolds number with magnetically actuated artificial cilia
Gauger, E. M., Downton, M. T., & Stark, H. (2008) · The European Physical Journal E · doi:10.1140/epje/i2008-10388-1 · Cited by 135
Fluid mechanics of nodal flow due to embryonic primary cilia
Smith, D. J., Blake, J. R., & Gaffney, E. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2007.1306 · Cited by 118
Active micromixer based on artificial cilia
Khatavkar, V. V., Anderson, P. D., den Toonder, J. M. J., & Meijer, H. E. H. (2007) · Physics of Fluids · doi:10.1063/1.2762206 · Cited by 115
Cited by
Bio-inspired magnetic swimming microrobots for biomedical applications
Peyer, K. E., Zhang, L., & Nelson, B. J. (2013) · Nanoscale · doi:10.1039/c2nr32554c · Cited by 820
Shape-programmable magnetic soft matter
Lum, G. Z., Ye, Z., Dong, X., Marvi, H., Erin, O., Hu, W., & Sitti, M. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1608193113 · Cited by 650
Photodeformable Azobenzene‐Containing Liquid Crystal Polymers and Soft Actuators
Pang, X., Lv, J., Zhu, C., Qin, L., & Yu, Y. (2019) · Advanced Materials · doi:10.1002/adma.201904224 · Cited by 514
Linking synchronization to self-assembly using magnetic Janus colloids
Yan, J., Bloom, M., Bae, S. C., Luijten, E., & Granick, S. (2012) · Nature · doi:10.1038/nature11619 · Cited by 430
Emergence of metachronal waves in cilia arrays
Elgeti, J., & Gompper, G. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1218869110 · Cited by 377
Metadata
- Authors
- Vilfan, M., Potočnik, A., Kavčič, B., Osterman, N., Poberaj, I., Vilfan, A., & Babič, D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-02-02
- Volume
- 107
- Issue
- 5
- Pages
- 1844-1847
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2120908282
- Cited by
- 262
- References
- 17
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.