Dynamic self-assembly and control of microfluidic particle crystals
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Engineered two-phase microfluidic systems have recently shown promise for computation, encryption, and biological processing. For many of these systems, complex control of dispersed-phase frequency and switching is enabled by nonlinearities associated with interfacial stresses. Introducing nonlinearity associated with fluid inertia has recently been identified as an easy to implement strategy to control two-phase (solid-liquid) microscale flows. By taking advantage of inertial effects we demonstrate controllable self-assembling particle systems, uncover dynamics suggesting a unique mechanism of dynamic self-assembly, and establish a framework for engineering microfluidic structures with the possibility of spatial frequency filtering. Focusing on the dynamics of the particle–particle interactions reveals a mechanism for the dynamic self-assembly process; inertial lift forces and a parabolic flow field act together to stabilize interparticle spacings that otherwise would diverge to infinity due to viscous disturbance flows. The interplay of the repulsive viscous interaction and inertial lift also allow us to design and implement microfluidic structures that irreversibly change interparticle spacing, similar to a low-pass filter. Although often not considered at the microscale, nonlinearity due to inertia can provide a platform for high-throughput passive control of particle positions in all directions, which will be useful for applications in flow cytometry, tissue engineering, and metamaterial synthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whitesides, G. M., & Grzybowski, B. (2002) · Science · doi:10.1126/science.1070821 · Cited by 7,439
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288 · cited 1×
“polydimethylsiloxane channels (44) to glass slides.”
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708 · cited 1×
“In addition to transverse migration, particles are observed to self-assemble into uniformly spaced flowing “lattices” with no external force fields (14).”
BackgroundSelf-citationDi Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Self-citationField-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983 · cited 1×
“P and programmable control of microscale droplets and particles is poised to facilitate new capabilities in biomedicine (1), materials synthesis (2), and computation (3–5), similar to how robust control of electrons enabled a myriad of applications in computation and communication.”
BackgroundLabel-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930 · cited 1×
“Control of the positions of microscale bioparticles, such as cells in flowing channels, is of great importance for flow cytometry (6), cell separation (7, 8), and cell diagnostics (9).”
BackgroundSelf-citationPatterns and collective behavior in granular media: Theoretical concepts
Aranson, I. S., & Tsimring, L. S. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.641 · Cited by 848
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Yamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Biophysical aspects of blood flow in the microvasculature
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00065-x · Cited by 553
Dynamic self-assembly of magnetized, millimetre-sized objects rotating at a liquid–air interface
Grzybowski, B. A., Stone, H. A., & Whitesides, G. M. (2000) · Nature · doi:10.1038/35016528 · Cited by 538
Self-citationPrakash, M., & Gershenfeld, N. (2007) · Science · doi:10.1126/science.1136907 · Cited by 511
Controlled encapsulation of single-cells into monodisperse picolitre drops
Edd, J. F., Di Carlo, D., Humphry, K. J., Köster, S., Irimia, D., Weitz, D. A., & Toner, M. (2008) · Lab on a Chip · doi:10.1039/b805456h · Cited by 511
Self-citationMicrodroplet-based PCR enrichment for large-scale targeted sequencing
Tewhey, R., Warner, J. B., Nakano, M., Libby, B., Medkova, M., David, P. H., Kotsopoulos, S. K., Samuels, M. L., Hutchison, J. B., Larson, J. W., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1583 · Cited by 454 · cited 1×
“P and programmable control of microscale droplets and particles is poised to facilitate new capabilities in biomedicine (1), materials synthesis (2), and computation (3–5), similar to how robust control of electrons enabled a myriad of applications in computation and communication.”
BackgroundSheathless inertial cell ordering for extreme throughput flow cytometry
Hur, S. C., Tse, H. T. K., & Di Carlo, D. (2010) · Lab Chip · doi:10.1039/b919495a · Cited by 368 · cited 1×
“However, fluid inertia has been used to manipulate the transverse position of particles in flow with exceptionally high throughput (15).”
MethodSelf-citationBarbee, J. H., & Cokelet, G. R. (1971) · Microvascular Research · doi:10.1016/0026-2862(71)90002-1 · Cited by 263 · cited 1×
“Besides implications for improvement of particle control in microfluidic systems, these results also have implications for blood flow near vessel walls (37, 38), suggesting limits to the dimensions of “cell-free layers” (39), and cell and particle diffusion in concentrated suspensions (40).”
BackgroundCalvert, P. (2007) · Science · doi:10.1126/science.1144212 · Cited by 224 · cited 1×
“In addition, improving the uniformity of local bioparticle concentrations at the microscale, by countering large statistical fluctuations away from the average bulk value can enable burgeoning fields such as “tissue printing” (10).”
BackgroundGeometrical focusing of cells in a microfluidic device: An approach to separate blood plasma
Faivre, M., Abkarian, M., Bickraj, K., & Stone, H. A. (2006) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2006043002001 · Cited by 196 · cited 1×
“Besides implications for improvement of particle control in microfluidic systems, these results also have implications for blood flow near vessel walls (37, 38), suggesting limits to the dimensions of “cell-free layers” (39), and cell and particle diffusion in concentrated suspensions (40).”
BackgroundSelf-citationPhonons in a one-dimensional microfluidic crystal
Beatus, T., Tlusty, T., & Bar-Ziv, R. (2006) · Nature Physics · doi:10.1038/nphys432 · Cited by 190 · cited 1×
“Potentially, this unique wave-like momentum transfer can be used to reveal nonequilibrium phenomena in self-assembled 1D particle systems as shown with microfluidic crystals (41, 42).”
BackgroundStationary shear flow around fixed and free bodies at finite Reynolds number
Mikulencak, D., & Morris, J. F. (2004) · Journal of Fluid Mechanics · doi:10.1017/s0022112004001648 · Cited by 136
Golosovsky, M., Saado, Y., & Davidov, D. (1999) · Applied Physics Letters · doi:10.1063/1.125571 · Cited by 127 · cited 1×
“Complete control of lattices of particles may also allow tunable fabrication of optical or acoustic metamaterials with controlled bandgaps (11, 12).”
BackgroundHydrodynamic Interaction in Confined Geometries
Diamant, H. (2009) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.78.041002 · Cited by 124 · cited 1×
“One possible explanation for observations of stable particle positions is that the repulsive interaction quickly decreases with interparticle spacing, In our high aspect ratio channel system the viscous interactions decay quickly with interparticle spacing; the interactions will decay in a manner similar to that due t…”
BackgroundHypersonic Modulation of Light in Three-Dimensional Photonic and Phononic Band-Gap Materials
Akimov, A. V., Tanaka, Y., Pevtsov, A. B., Kaplan, S. F., Golubev, V. G., Tamura, S.-I., Yakovlev, D. R., & Bayer, M. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.033902 · Cited by 116
Flowing Crystals: Nonequilibrium Structure of Foam
Garstecki, P., & Whitesides, G. M. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.024503 · Cited by 79 · cited 1×
“Potentially, this unique wave-like momentum transfer can be used to reveal nonequilibrium phenomena in self-assembled 1D particle systems as shown with microfluidic crystals (41, 42).”
BackgroundDynamic Self-Assembly of Rings of Charged Metallic Spheres
Grzybowski, B. A., Wiles, J. A., & Whitesides, G. M. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.083903 · Cited by 53
Complexity and dynamic self-assembly
Grzybowski, B. A., & Campbell, C. J. (2004) · Chemical Engineering Science · doi:10.1016/j.ces.2004.01.023 · Cited by 50
Cited by
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Autonomous Motion of Metallic Microrods Propelled by Ultrasound
Wang, W., Castro, L. A., Hoyos, M., & Mallouk, T. E. (2012) · ACS Nano · doi:10.1021/nn301312z · Cited by 736
Amini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Self-citationDeformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Self-citationInertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Metadata
- Authors
- Lee, W., Amini, H., Stone, H. A., & Di Carlo, D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-12-13
- Volume
- 107
- Issue
- 52
- Pages
- 22413-22418
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2022394827
- Cited by
- 209
- References
- 28
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.