Dynamic self-assembly and control of microfluidic particle crystals
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Engineered two-phase microfluidic systems have recently shown promise for computation, encryption, and biological processing. For many of these systems, complex control of dispersed-phase frequency and switching is enabled by nonlinearities associated with interfacial stresses. Introducing nonlinearity associated with fluid inertia has recently been identified as an easy to implement strategy to control two-phase (solid-liquid) microscale flows. By taking advantage of inertial effects we demonstrate controllable self-assembling particle systems, uncover dynamics suggesting a unique mechanism of dynamic self-assembly, and establish a framework for engineering microfluidic structures with the possibility of spatial frequency filtering. Focusing on the dynamics of the particle–particle interactions reveals a mechanism for the dynamic self-assembly process; inertial lift forces and a parabolic flow field act together to stabilize interparticle spacings that otherwise would diverge to infinity due to viscous disturbance flows. The interplay of the repulsive viscous interaction and inertial lift also allow us to design and implement microfluidic structures that irreversibly change interparticle spacing, similar to a low-pass filter. Although often not considered at the microscale, nonlinearity due to inertia can provide a platform for high-throughput passive control of particle positions in all directions, which will be useful for applications in flow cytometry, tissue engineering, and metamaterial synthesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whitesides, G. M., & Grzybowski, B. (2002) · Science · doi:10.1126/science.1070821 · Cited by 7,439
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288 · cited 1×
“polydimethylsiloxane channels (44) to glass slides.”
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708 · cited 1×
“In addition to transverse migration, particles are observed to self-assemble into uniformly spaced flowing “lattices” with no external force fields (14).”
BackgroundSelf-citationDi Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Self-citationField-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983 · cited 1×
“P and programmable control of microscale droplets and particles is poised to facilitate new capabilities in biomedicine (1), materials synthesis (2), and computation (3–5), similar to how robust control of electrons enabled a myriad of applications in computation and communication.”
BackgroundLabel-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930 · cited 1×
“Control of the positions of microscale bioparticles, such as cells in flowing channels, is of great importance for flow cytometry (6), cell separation (7, 8), and cell diagnostics (9).”
BackgroundSelf-citationPatterns and collective behavior in granular media: Theoretical concepts
Aranson, I. S., & Tsimring, L. S. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.641 · Cited by 848
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Yamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Cited by
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Autonomous Motion of Metallic Microrods Propelled by Ultrasound
Wang, W., Castro, L. A., Hoyos, M., & Mallouk, T. E. (2012) · ACS Nano · doi:10.1021/nn301312z · Cited by 736
Amini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Self-citationDeformability-based cell classification and enrichment using inertial microfluidics
Hur, S. C., Henderson-MacLennan, N. K., McCabe, E. R. B., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c0lc00595a · Cited by 576
Self-citationInertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
Fundamentals of inertial focusing in microchannels
Zhou, J., & Papautsky, I. (2013) · Lab on a Chip · doi:10.1039/c2lc41248a · Cited by 446
Hydrodynamic mechanisms of cell and particle trapping in microfluidics
Karimi, A., Yazdi, S., & Ardekani, A. M. (2013) · Biomicrofluidics · doi:10.1063/1.4799787 · Cited by 384
High-throughput single-microparticle imaging flow analyzer
Goda, K., Ayazi, A., Gossett, D. R., Sadasivam, J., Lonappan, C. K., Sollier, E., Fard, A. M., Hur, S. C., Adam, J., Murray, C., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204718109 · Cited by 384
Self-citationFrom dynamic self-assembly to networked chemical systems
Grzybowski, B. A., Fitzner, K., Paczesny, J., & Granick, S. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00089h · Cited by 302
Odd dynamics of living chiral crystals
Tan, T. H., Mietke, A., Li, J., Chen, Y., Higinbotham, H., Foster, P. J., Gokhale, S., Dunkel, J., & Fakhri, N. (2022) · Nature · doi:10.1038/s41586-022-04889-6 · Cited by 280
Automated cellular sample preparation using a Centrifuge-on-a-Chip
Mach, A. J., Kim, J. H., Arshi, A., Hur, S. C., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20330d · Cited by 280
Self-citationRecent progress of particle migration in viscoelastic fluids
Yuan, D., Zhao, Q., Yan, S., Tang, S.-Y., Alici, G., Zhang, J., & Li, W. (2018) · Lab on a Chip · doi:10.1039/c7lc01076a · Cited by 258
Engineering fluid flow using sequenced microstructures
Amini, H., Sollier, E., Masaeli, M., Xie, Y., Ganapathysubramanian, B., Stone, H. A., & Di Carlo, D. (2013) · Nature Communications · doi:10.1038/ncomms2841 · Cited by 173
Self-citationComputational inertial microfluidics: a review
Razavi Bazaz, S., Mashhadian, A., Ehsani, A., Saha, S. C., Krüger, T., & Ebrahimi Warkiani, M. (2020) · Lab on a Chip · doi:10.1039/c9lc01022j · Cited by 166
Inertial Manipulation and Transfer of Microparticles Across Laminar Fluid Streams
Gossett, D. R., Tse, H. T. K., Dudani, J. S., Goda, K., Woods, T. A., Graves, S. W., & Di Carlo, D. (2012) · Small · doi:10.1002/smll.201200588 · Cited by 163
Self-citation
Metadata
- Authors
- Lee, W., Amini, H., Stone, H. A., & Di Carlo, D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-12-13
- Volume
- 107
- Issue
- 52
- Pages
- 22413-22418
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2022394827
- Cited by
- 209
- References
- 28
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.