High sensitivity nanoparticle detection using optical microcavities
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
We demonstrate a highly sensitive nanoparticle and virus detection method by using a thermal-stabilized reference interferometer in conjunction with an ultrahigh-Q microcavity. Sensitivity is sufficient to resolve shifts caused by binding of individual nanobeads in solution down to a record radius of 12.5 nm, a size approaching that of single protein molecules. A histogram of wavelength shift versus nanoparticle radius shows that particle size can be inferred from shift maxima. Additionally, the signal-to-noise ratio for detection of Influenza A virus is enhanced to 38∶1 from the previously reported 3∶1. The method does not use feedback stabilization of the probe laser. It is also observed that the conjunction of particle-induced backscatter and optical-path-induced shifts can be used to enhance detection signal-to-noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
Vahala, K. J. (2003) · Nature · doi:10.1038/nature01939 · Cited by 4,878
Self-citationUltra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214 · cited 2×
“Silica microspheres (7) or silica microtoroids (8, 9) provide an easily functionalized detection surface that directly interacts with a high-quality-factor (Q) whispering gallery mode.”
BackgroundSelf-citationWhispering-gallery-mode biosensing: label-free detection down to single molecules
Vollmer, F., & Arnold, S. (2008) · Nature Methods · doi:10.1038/nmeth.1221 · Cited by 1,660
On-chip single nanoparticle detection and sizing by mode splitting in an ultrahigh-Q microresonator
Zhu, J., Ozdemir, S. K., Xiao, Y.-F., Li, L., He, L., Chen, D.-R., & Yang, L. (2010) · Nature Photonics · doi:10.1038/nphoton.2009.237 · Cited by 1,198
Cai, M., Painter, O., & Vahala, K. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.74 · Cited by 912
Self-citationProtein detection by optical shift of a resonant microcavity
Vollmer, F., Braun, D., Libchaber, A., Khoshsima, M., Teraoka, I., & Arnold, S. (2002) · Applied Physics Letters · doi:10.1063/1.1482797 · Cited by 903
Shift of whispering-gallery modes in microspheres by protein adsorption
Arnold, S., Khoshsima, M., Teraoka, I., Holler, S., & Vollmer, F. (2003) · Optics Letters · doi:10.1364/ol.28.000272 · Cited by 736
Towards single-molecule nanomechanical mass spectrometry
Naik, A. K., Hanay, M. S., Hiebert, W. K., Feng, X. L., & Roukes, M. L. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.152 · Cited by 683
Spillane, S. M., Kippenberg, T. J., Painter, O. J., & Vahala, K. J. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.043902 · Cited by 650
Self-citationRayleigh scattering in high-Q microspheres
Gorodetsky, M. L., Pryamikov, A. D., & Ilchenko, V. S. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.001051 · Cited by 525
Label-free screening of bio-molecular interactions
Cooper, M. A. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2111-y · Cited by 460
Modal coupling in traveling-wave resonators
Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2002) · Optics Letters · doi:10.1364/ol.27.001669 · Cited by 396
Self-citation(2024) · Physics Subject Headings (PhySH) · doi:10.29172/5802dce1-0079-4688-9f4e-a79871191efc · Cited by 256
Oxborrow, M. (2007) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2007.897850 · Cited by 255
Oxborrow, M. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 230
Cited by
Whispering gallery mode sensors
Foreman, M. R., Swaim, J. D., & Vollmer, F. (2015) · Advances in Optics and Photonics · doi:10.1364/aop.7.000168 · Cited by 927
Zijlstra, P., Paulo, P. M. R., & Orrit, M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.51 · Cited by 788
Whispering gallery microcavity lasers
He, L., Özdemir, Ş. K., & Yang, L. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201100032 · Cited by 646
Single-molecule nucleic acid interactions monitored on a label-free microcavity biosensor platform
Baaske, M. D., Foreman, M. R., & Vollmer, F. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.180 · Cited by 559
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
Metadata
- Authors
- Lu, T., Lee, H., Chen, T., Herchak, S., Kim, J.-H., Fraser, S. E., Flagan, R. C., & Vahala, K.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-03-28
- Volume
- 108
- Issue
- 15
- Pages
- 5976-5979
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2042024782
- Cited by
- 308
- References
- 16
- FWCI
- 23.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.