Long-term in vivo glucose monitoring using fluorescent hydrogel fibers
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The use of fluorescence-based sensors holds great promise for continuous glucose monitoring (CGM) in vivo, allowing wireless transdermal transmission and long-lasting functionality in vivo. The ability to monitor glucose concentrations in vivo over the long term enables the sensors to be implanted and replaced less often, thereby bringing CGM closer to practical implementation. However, the full potential of long-term in vivo glucose monitoring has yet to be realized because current fluorescence-based sensors cannot remain at an implantation site and respond to blood glucose concentrations over an extended period. Here, we present a long-term in vivo glucose monitoring method using glucose-responsive fluorescent hydrogel fibers. We fabricated glucose-responsive fluorescent hydrogels in a fibrous structure because this structure enables the sensors to remain at the implantation site for a long period. Moreover, these fibers allow easy control of the amount of fluorescent sensors implanted, simply by cutting the fibers to the desired length, and facilitate sensor removal from the implantation site after use. We found that the polyethylene glycol (PEG)-bonded polyacrylamide (PAM) hydrogel fibers reduced inflammation compared with PAM hydrogel fibers, transdermally glowed, and continuously responded to blood glucose concentration changes for up to 140 days, showing their potential application for long-term in vivo continuous glucose monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · cited 1×
“However, these methods have several drawbacks for long-term use because these enzyme based sensors are insufficiently stable in vivo (1), they are poorly accurate in low glucose concentrations (2), and their activity is oxygen-dependent (3).”
BackgroundDelves, P. J., & Roitt, I. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007063430107 · Cited by 1,666
Glucose oxidase: an ideal enzyme
Wilson, R., & Turner, A. P. F. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87013-f · Cited by 1,350
Electrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,159
Surface Treatments of Polymers for Biocompatibility
Elbert, D. L., & Hubbell, J. A. (1996) · Annual Review of Materials Science · doi:10.1146/annurev.ms.26.080196.002053 · Cited by 531
James, T. D., Sandanayake, K. R. A. S., Iguchi, R., & Shinkai, S. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00140a013 · Cited by 485
Wavelength dependence of skin cancer induction by ultraviolet irradiation of albino hairless mice.
de Gruijl, F. R., Sterenborg, H. J. C. M., Forbes, P. D., Davies, R. E., Cole, C. A., Kelfkens, G., van Weelden, H., Slaper, H., & van der Leun, J. C. (1993) · PubMed · Cited by 471
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 418
Russell, R. J., Pishko, M. V., Gefrides, C. C., McShane, M. J., & Coté, G. L. (1999) · Analytical Chemistry · doi:10.1021/ac990060r · Cited by 353
Cited by
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Synthesis and Applications of Boronic Acid-Containing Polymers: From Materials to Medicine
Brooks, W. L. A., & Sumerlin, B. S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00300 · Cited by 981
Yu, J., Zhang, Y., Ye, Y., DiSanto, R., Sun, W., Ranson, D., Ligler, F. S., Buse, J. B., & Gu, Z. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1505405112 · Cited by 848
Selective sensing of saccharides using simple boronic acids and their aggregates
Wu, X., Li, Z., Chen, X.-X., Fossey, J. S., James, T. D., & Jiang, Y.-B. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60148j · Cited by 628
Bioactive hydrogels for bone regeneration
Bai, X., Gao, M., Syed, S., Zhuang, J., Xu, X., & Zhang, X.-Q. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2018.05.006 · Cited by 556
Smart drug delivery systems: from fundamentals to the clinic
Alvarez-Lorenzo, C., & Concheiro, A. (2014) · Chem. Commun. · doi:10.1039/c4cc01429d · Cited by 415
Döring, A., Birnbaum, W., & Kuckling, D. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60031a · Cited by 391
Glucose Sensing in Supramolecular Chemistry
Sun, X., & James, T. D. (2015) · Chemical Reviews · doi:10.1021/cr500562m · Cited by 386
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Optical Fiber Sensors: Working Principle, Applications, and Limitations
Elsherif, M., Salih, A. E., Muñoz, M. G., Alam, F., AlQattan, B., Antonysamy, D. S., Zaki, M. F., Yetisen, A. K., Park, S., Wilkinson, T. D., et al. (2022) · Advanced Photonics Research · doi:10.1002/adpr.202100371 · Cited by 330
Glucose‐Sensitive Hydrogel Optical Fibers Functionalized with Phenylboronic Acid
Yetisen, A. K., Jiang, N., Fallahi, A., Montelongo, Y., Ruiz‐Esparza, G. U., Tamayol, A., Zhang, Y. S., Mahmood, I., Yang, S., Kim, K. S., et al. (2017) · Advanced Materials · doi:10.1002/adma.201606380 · Cited by 311
Functional Fiber Materials to Smart Fiber Devices
Chen, C., Feng, J., Li, J., Guo, Y., Shi, X., & Peng, H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00192 · Cited by 308
Lee, I., Probst, D., Klonoff, D., & Sode, K. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113054 · Cited by 288
Hypoxia and H2O2 Dual-Sensitive Vesicles for Enhanced Glucose-Responsive Insulin Delivery
Yu, J., Qian, C., Zhang, Y., Cui, Z., Zhu, Y., Shen, Q., Ligler, F. S., Buse, J. B., & Gu, Z. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b03848 · Cited by 280
Nonspecific Binding—Fundamental Concepts and Consequences for Biosensing Applications
Frutiger, A., Tanno, A., Hwu, S., Tiefenauer, R. F., Vörös, J., & Nakatsuka, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00044 · Cited by 278
Flexible pH‐Sensing Hydrogel Fibers for Epidermal Applications
Tamayol, A., Akbari, M., Zilberman, Y., Comotto, M., Lesha, E., Serex, L., Bagherifard, S., Chen, Y., Fu, G., Ameri, S. K., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201500553 · Cited by 262
Microfluidic Spinning of Flat Alginate Fibers with Grooves for Cell‐Aligning Scaffolds
Kang, E., Choi, Y. Y., Chae, S., Moon, J., Chang, J., & Lee, S. (2012) · Advanced Materials · doi:10.1002/adma.201201232 · Cited by 245
Li, W., Liu, J., Wei, J., Yang, Z., Ren, C., & Li, B. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202213485 · Cited by 233
Brown, M. S., Ashley, B., & Koh, A. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00047 · Cited by 227
“, 2014), fluorescent hydrogel fibers (Heo et al., 2011) and injectable hydrogel microbeads (Shibata et al.”
BackgroundSkin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
Ratiometric Fluorescent Nanohybrid for Noninvasive and Visual Monitoring of Sweat Glucose
Cui, Y., Duan, W., Jin, Y., Wo, F., Xi, F., & Wu, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00718 · Cited by 177
Metadata
- Authors
- Heo, Y. J., Shibata, H., Okitsu, T., Kawanishi, T., & Takeuchi, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-08
- Volume
- 108
- Issue
- 33
- Pages
- 13399-13403
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2112740753
- Cited by
- 310
- References
- 20
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.