Long-term in vivo glucose monitoring using fluorescent hydrogel fibers
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The use of fluorescence-based sensors holds great promise for continuous glucose monitoring (CGM) in vivo, allowing wireless transdermal transmission and long-lasting functionality in vivo. The ability to monitor glucose concentrations in vivo over the long term enables the sensors to be implanted and replaced less often, thereby bringing CGM closer to practical implementation. However, the full potential of long-term in vivo glucose monitoring has yet to be realized because current fluorescence-based sensors cannot remain at an implantation site and respond to blood glucose concentrations over an extended period. Here, we present a long-term in vivo glucose monitoring method using glucose-responsive fluorescent hydrogel fibers. We fabricated glucose-responsive fluorescent hydrogels in a fibrous structure because this structure enables the sensors to remain at the implantation site for a long period. Moreover, these fibers allow easy control of the amount of fluorescent sensors implanted, simply by cutting the fibers to the desired length, and facilitate sensor removal from the implantation site after use. We found that the polyethylene glycol (PEG)-bonded polyacrylamide (PAM) hydrogel fibers reduced inflammation compared with PAM hydrogel fibers, transdermally glowed, and continuously responded to blood glucose concentration changes for up to 140 days, showing their potential application for long-term in vivo continuous glucose monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · cited 1×
“However, these methods have several drawbacks for long-term use because these enzyme based sensors are insufficiently stable in vivo (1), they are poorly accurate in low glucose concentrations (2), and their activity is oxygen-dependent (3).”
BackgroundDelves, P. J., & Roitt, I. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007063430107 · Cited by 1,666
Glucose oxidase: an ideal enzyme
Wilson, R., & Turner, A. P. F. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87013-f · Cited by 1,350
Electrochemical non-enzymatic glucose sensors
Park, S., Boo, H., & Chung, T. D. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.05.080 · Cited by 1,159
Surface Treatments of Polymers for Biocompatibility
Elbert, D. L., & Hubbell, J. A. (1996) · Annual Review of Materials Science · doi:10.1146/annurev.ms.26.080196.002053 · Cited by 531
James, T. D., Sandanayake, K. R. A. S., Iguchi, R., & Shinkai, S. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00140a013 · Cited by 485
Wavelength dependence of skin cancer induction by ultraviolet irradiation of albino hairless mice.
de Gruijl, F. R., Sterenborg, H. J. C. M., Forbes, P. D., Davies, R. E., Cole, C. A., Kelfkens, G., van Weelden, H., Slaper, H., & van der Leun, J. C. (1993) · PubMed · Cited by 471
Onuki, Y., Bhardwaj, U., Papadimitrakopoulos, F., & Burgess, D. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200610 · Cited by 418
Russell, R. J., Pishko, M. V., Gefrides, C. C., McShane, M. J., & Coté, G. L. (1999) · Analytical Chemistry · doi:10.1021/ac990060r · Cited by 353
Effect of Chain Density on Inhibition of Protein Adsorption by Poly(ethylene glycol) Based Coatings
Malmsten, M., Emoto, K., & Van Alstine, J. M. (1998) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5513 · Cited by 342
Freeman, S. E., Hacham, H., Gange, R. W., Maytum, D. J., Sutherland, J. C., & Sutherland, B. M. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.14.5605 · Cited by 311 · cited 1×
“7 mW·cm−2) for 1 ms every 5 min, this amount of the excitation light exposure is negligible with respect to skin radiation damage and cancer development (23, 24).”
BackgroundInjectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring
Shibata, H., Heo, Y. J., Okitsu, T., Matsunaga, Y., Kawanishi, T., & Takeuchi, S. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006911107 · Cited by 287
Self-citationTSURUFUJI, S., SUGIO, K., & TAKEMASA, F. (1979) · Nature · doi:10.1038/280408a0 · Cited by 216
Continuous Subcutaneous Glucose Monitoring in Diabetic Patients
Maran, A., Crepaldi, C., Tiengo, A., Grassi, G., Vitali, E., Pagano, G., Bistoni, S., Calabrese, G., Santeusanio, F., Leonetti, F., et al. (2002) · Diabetes Care · doi:10.2337/diacare.25.2.347 · Cited by 198
Bridgett, M. J., Davies, M. C., & Denyer, S. P. (1992) · Biomaterials · doi:10.1016/0142-9612(92)90159-l · Cited by 155
Norton, L. W., Tegnell, E., Toporek, S. S., & Reichert, W. M. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.069 · Cited by 113
Saccharide-Selective Boronic Acid Based Photoinduced Electron Transfer (PET) Fluorescent Sensors
James, T. D. (2007) · Springer eBooks · doi:10.1007/128_2007_110 · Cited by 111
DeFife, K. M., Shive, M. S., Hagen, K. M., Clapper, D. L., & Anderson, J. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19990305)44:3<298::aid-jbm8>3.0.co;2-n · Cited by 81
Skin inflammation induced by reactive oxygen species (ROS): an in-vivo model
TRENAM, C. W., DABBAGH, A. J., MORRIS, C. J., & BLAKE, D. R. (1991) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1991.tb14165.x · Cited by 55 · cited 1×
“PEG, a well-known biomaterial (11), was covalently bonded to the fluorescent hydrogel fibers, thereby reducing inflammation (12, 13).”
Background
Cited by
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Synthesis and Applications of Boronic Acid-Containing Polymers: From Materials to Medicine
Brooks, W. L. A., & Sumerlin, B. S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00300 · Cited by 981
Yu, J., Zhang, Y., Ye, Y., DiSanto, R., Sun, W., Ranson, D., Ligler, F. S., Buse, J. B., & Gu, Z. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1505405112 · Cited by 848
Selective sensing of saccharides using simple boronic acids and their aggregates
Wu, X., Li, Z., Chen, X.-X., Fossey, J. S., James, T. D., & Jiang, Y.-B. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60148j · Cited by 628
Metadata
- Authors
- Heo, Y. J., Shibata, H., Okitsu, T., Kawanishi, T., & Takeuchi, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-08
- Volume
- 108
- Issue
- 33
- Pages
- 13399-13403
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2112740753
- Cited by
- 310
- References
- 20
- FWCI
- 6.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.