High-throughput single-microparticle imaging flow analyzer
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Optical microscopy is one of the most widely used diagnostic methods in scientific, industrial, and biomedical applications. However, while useful for detailed examination of a small number (< 10,000) of microscopic entities, conventional optical microscopy is incapable of statistically relevant screening of large populations (> 100,000,000) with high precision due to its low throughput and limited digital memory size. We present an automated flow-through single-particle optical microscope that overcomes this limitation by performing sensitive blur-free image acquisition and nonstop real-time image-recording and classification of microparticles during high-speed flow. This is made possible by integrating ultrafast optical imaging technology, self-focusing microfluidic technology, optoelectronic communication technology, and information technology. To show the system’s utility, we demonstrate high-throughput image-based screening of budding yeast and rare breast cancer cells in blood with an unprecedented throughput of 100,000 particles/s and a record false positive rate of one in a million.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
Zweig, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,569
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Shapiro, H. M. (2003) · Wiley eBooks · doi:10.1002/0471722731 · Cited by 2,671
The Statistical Evaluation of Medical Tests for Classification and Prediction
(2005) · Technometrics · doi:10.1198/tech.2005.s278 · Cited by 1,899
Handbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Self-citationDi Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Self-citationSupport Vector Machines: Theory and Applications
(2005) · Studies in Fuzziness and Soft Computing · doi:10.1007/b95439 · Cited by 1,493
Super-resolution Aperture Scanning Microscope
ASH, E. A., & NICHOLLS, G. (1972) · Nature · doi:10.1038/237510a0 · Cited by 953
Fluorescence Activated Cell Sorting
Bonner, W. A., Hulett, H. R., Sweet, R. G., & Herzenberg, L. A. (1972) · Review of Scientific Instruments · doi:10.1063/1.1685647 · Cited by 777
Serial time-encoded amplified imaging for real-time observation of fast dynamic phenomena
Goda, K., Tsia, K. K., & Jalali, B. (2009) · Nature · doi:10.1038/nature07980 · Cited by 763
Self-citationCellular Image Analysis and Imaging by Flow Cytometry
Basiji, D. A., Ortyn, W. E., Liang, L., Venkatachalam, V., & Morrissey, P. (2007) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2007.05.008 · Cited by 426
High-Speed Imaging of Drops and Bubbles
Thoroddsen, S. T., Etoh, T. G., & Takehara, K. (2008) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102215 · Cited by 417
Rapid prototyping polymers for microfluidic devices and high pressure injections
Sollier, E., Murray, C., Maoddi, P., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20514e · Cited by 407
Self-citationWestphal, V., Rizzoli, S. O., Lauterbach, M. A., Kamin, D., & Hell, S. W. (2009) · Advances in Imaging · doi:10.1364/ntm.2009.nma1 · Cited by 365
Introduction to Optical Microscopy
Mertz, J. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108552660 · Cited by 352
Cellular imaging in drug discovery
Lang, P., Yeow, K., Nichols, A., & Scheer, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2008 · Cited by 351
Amplified wavelength–time transformation for real-time spectroscopy
Solli, D. R., Chou, J. T., & Jalali, B. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.253 · Cited by 289
Self-citationTracking epitope-specific T cells
Moon, J. J., Chu, H. H., Hataye, J., Pagán, A. J., Pepper, M., McLachlan, J. B., Zell, T., & Jenkins, M. K. (2009) · Nature Protocols · doi:10.1038/nprot.2009.9 · Cited by 288
Biofuels Engineering Process Technology
(2008) · Focus on Catalysts · doi:10.1016/s1351-4180(08)70584-1 · Cited by 273
Particle Focusing Mechanisms in Curving Confined Flows
Gossett, D. R., & Carlo, D. D. (2009) · Analytical Chemistry · doi:10.1021/ac901306y · Cited by 246
Self-citationDynamic self-assembly and control of microfluidic particle crystals
Lee, W., Amini, H., Stone, H. A., & Di Carlo, D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1010297107 · Cited by 209
Self-citationTiwari, V., Sutton, M. A., & McNeill, S. R. (2007) · Experimental Mechanics · doi:10.1007/s11340-006-9011-y · Cited by 196
Automated microscopy for high-content RNAi screening
Conrad, C., & Gerlich, D. W. (2010) · Journal of Cell Biology · doi:10.1083/jcb.200910105 · Cited by 168
A micromachined high throughput Coulter counter for bioparticle detection and counting
Zhe, J., Jagtiani, A. V., Dutta, P., Hu, J., & Carletta, J. E. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/2/017 · Cited by 160
History of haematopoietic stem-cell transplantation
Little, M.-T., & Storb, R. F. (2002) · Nature reviews. Cancer · doi:10.1038/nrc748 · Cited by 141
High throughput microscopy: from raw images to discoveries
Wollman, R., & Stuurman, N. (2007) · Journal of Cell Science · doi:10.1242/jcs.013623 · Cited by 101
Super-resolution microscopy: breaking the limits
Chi, K. R. (2008) · Nature Methods · doi:10.1038/nmeth.f.234 · Cited by 76
Calvert, M. E. K., Lannigan, J. A., & Pemberton, L. F. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20609 · Cited by 63
Kay, D. B., Cambier, J. L., & Wheeless, L. L. (1979) · Journal of Histochemistry & Cytochemistry · doi:10.1177/27.1.374597 · Cited by 61
Rosenblatt, J. I., Hokanson, J. A., McLaughlin, S. R., & Leary, J. F. (1997) · Cytometry · doi:10.1002/(sici)1097-0320(19970301)27:3<233::aid-cyto4>3.0.co;2-f · Cited by 45
Huls, P. G., Nanninga, N., van Spronsen, E. A., Valkenburg, J. A. C., Vishcer, N. O. E., & Woldringh, C. L. (1992) · Biotechnology and Bioengineering · doi:10.1002/bit.260390313 · Cited by 44
History of Hematopoietic Stem Cell Transplantation
Ezzone, S. A. (2009) · Seminars in Oncology Nursing · doi:10.1016/j.soncn.2009.03.004 · Cited by 23
Cited by
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Dispersive Fourier transformation for fast continuous single-shot measurements
Goda, K., & Jalali, B. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.359 · Cited by 1,007
Self-citationSingle-cell RNA-seq: advances and future challenges
Saliba, A.-E., Westermann, A. J., Gorski, S. A., & Vogel, J. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku555 · Cited by 847
“Developments in flow imaging-based cytometry (55,56) may address this problem in the future.”
Amini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Self-citationTime stretch and its applications
Mahjoubfar, A., Churkin, D. V., Barland, S., Broderick, N., Turitsyn, S. K., & Jalali, B. (2017) · Nature Photonics · doi:10.1038/nphoton.2017.76 · Cited by 483
Self-citation
Metadata
- Authors
- Goda, K., Ayazi, A., Gossett, D. R., Sadasivam, J., Lonappan, C. K., Sollier, E., Fard, A. M., Hur, S. C., Adam, J., Murray, C., Wang, C., Brackbill, N., Di Carlo, D., & Jalali, B.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-07-02
- Volume
- 109
- Issue
- 29
- Pages
- 11630-11635
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2029739655
- Cited by
- 384
- References
- 37
- FWCI
- 18.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.