Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

Capillary muscle

Open access
Cohen, Caroline, Mouterde, Timothée, Quéré, David, Clanet, Christophe · 2015 · Proceedings of the National Academy of Sciences

Abstract

Significance: The force generated by a muscle decreases when its contraction velocity increases. This rheology follows the heuristic Hill’s equation. Here, we design and study a capillary analog in which the myosin–actin interaction is replaced by the wetting affinity between a Newtonian silicone oil and a steel rod. This device contracts and generates a force that also decreases with increasing contraction speed, following the same Hill’s equation. The physical origin of this attractive equation is discussed together with the analogy between the actin–myosin system and the capillary one. Apart from its academic interest, this capillary muscle can also have extensions in technology to produce forces and motion using surface chemical energies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.1419315112

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 39 references

Research works printed but not linked: 1

  1. KD Keele Corpus of the Anatomical Works in the Collection of Her Majesty the Queen (Johnson, New York, 1979).

Cited by

See all 46

Metadata

Authors
Cohen, C., Mouterde, T., Quéré, D., & Clanet, C.
Affiliations
Centre National de la Recherche Scientifique (FR)
Venue
Proceedings of the National Academy of Sciences
Published
2015-05-05
Volume
112
Issue
20
Pages
6301-6306
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2575349992
Cited by
40
References
39
Citations by year
2026: 3 · 2025: 11 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 3 · 2017: 2 · 2016: 2 · 2015: 1
FWCI
1.42
Type
journal article
Language
en
Open access
Locations
  • Proceedings of the National Academy of Sciences (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • HAL (submittedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
  • Health Sciences › Medicine › Hematology › Blood properties and coagulation
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiomyopathy and Myosin Studies
Keywords
force-velocity relationship, Hill equation, sarcomere, sliding filament theory, muscle contraction, force generation, contraction velocity
MeSH terms
Actins, Animals, Biomechanical Phenomena, Capillaries, Humans, Models, Biological, Muscle Contraction, Muscle, Smooth, Vascular, Myosins, Silicone Oils, Steel

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Capillary muscle. https://app.cochat.ai/papers/10.1073/pnas.1419315112
The paper
Cohen, C., Mouterde, T., Quéré, D., & Clanet, C. (2015). Capillary muscle. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1419315112

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.