The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Non-invasive detection of animal nerve impulses with an atomic magnetometer operating near quantum limited sensitivity
Open accessAbstract
Magnetic fields generated by human and animal organs, such as the heart, brain and nervous system carry information useful for biological and medical purposes. These magnetic fields are most commonly detected using cryogenically-cooled superconducting magnetometers. Here we present the first detection of action potentials from an animal nerve using an optical atomic magnetometer. Using an optimal design we are able to achieve the sensitivity dominated by the quantum shot noise of light and quantum projection noise of atomic spins. Such sensitivity allows us to measure the nerve impulse with a miniature room-temperature sensor which is a critical advantage for biomedical applications. Positioning the sensor at a distance of a few millimeters from the nerve, corresponding to the distance between the skin and nerves in biological studies, we detect the magnetic field generated by an action potential of a frog sciatic nerve. From the magnetic field measurements we determine the activity of the nerve and the temporal shape of the nerve impulse. This work opens new ways towards implementing optical magnetometers as practical devices for medical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“More generally, quantum technologies, such as quantum sensing, [243] might enhance the quality of imaging data of biomolecular structures (see e. g.Ref. [244]) and, therefore, improve the quality of the data on which further classical or quantum computations would be based.”
From Quantum Computing for Molecular Biology** (2023) · cites this paper as [244]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“For example, femtoTesla sensitivity has been achieved with magnetometers operating at a temperature of several hundred of ◦C in the so-called SERF regime [3] used also for medical applications [4–6].”
Optical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
Magnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Quantum Noise Limited and Entanglement-Assisted Magnetometry
Wasilewski, W., Jensen, K., Krauter, H., Renema, J. J., Balabas, M. V., & Polzik, E. S. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.133601 · Cited by 434
Self-citationSubfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Magnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
Magnetoencephalography: From SQUIDs to neuroscience
Hari, R., & Salmelin, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.074 · Cited by 285
Polarized Alkali-Metal Vapor with Minute-Long Transverse Spin-Relaxation Time
Balabas, M. V., Karaulanov, T., Ledbetter, M. P., & Budker, D. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.070801 · Cited by 272
Self-citation
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
Optimal and secure measurement protocols for quantum sensor networks
Eldredge, Z., Foss-Feig, M., Gross, J. A., Rolston, S. L., & Gorshkov, A. V. (2018) · Physical Review A · doi:10.1103/physreva.97.042337 · Cited by 170
How to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
Optimal Control for One-Qubit Quantum Sensing
Poggiali, F., Cappellaro, P., & Fabbri, N. (2018) · Physical Review X · doi:10.1103/physrevx.8.021059 · Cited by 117
Metadata
- Authors
- Jensen, K., Budvytyte, R., Thomas, R. A., Wang, T., Fuchs, A. M., Balabas, M. V., Vasilakis, G., Mosgaard, L. D., Stærkind, H. C., Müller, J. H., Heimburg, T., Olesen, S.-P., & Polzik, E. S.
- Affiliations
- University of Copenhagen (DK)
- Corresponding author
- Polzik, Eugene S.
- Venue
- Scientific Reports
- Published
- 2016-07-15
- Volume
- 6
- Issue
- 1
- Pages
- 29638-29638
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC4945862
- OpenAlex
- W2239059663
- Cited by
- 64
- References
- 20
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 6 · 2023: 5 · 2022: 8 · 2021: 7 · 2020: 4 · 2019: 10 · 2018: 6 · 2017: 10
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Repository@Nottingham (University of Nottingham) (publishedVersion, cc-by)
- Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, other-oa)
- arXiv (Cornell University) (submittedVersion)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Defense Advanced Research Projects Agency
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- action potential, quantum shot noise, quantum projection noise, quantum-limited sensitivity, room-temperature magnetometry, frog sciatic nerve, non-invasive sensing, medical diagnostics
- MeSH terms
- Action Potentials, Animals, Anura, Magnetics, Sciatic Nerve, Quantum Dots
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive detection of animal nerve impulses with an atomic magnetometer operating near quantum limited sensitivity. https://app.cochat.ai/papers/10.1038/srep29638
- The paper
- Jensen, K., Budvytyte, R., Thomas, R. A., Wang, T., Fuchs, A. M., Balabas, M. V., Vasilakis, G., Mosgaard, L. D., Stærkind, H. C., Müller, J. H., Heimburg, T., Olesen, S.-P., & Polzik, E. S. (2016). Non-invasive detection of animal nerve impulses with an atomic magnetometer operating near quantum limited sensitivity. Scientific Reports. https://doi.org/10.1038/srep29638
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.