In vivo optical imaging of physiological responses to photostimulation in human photoreceptors
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Significance: Using a full-field optical coherence tomography system, we measured changes in the time that light requires to pass through photoreceptor outer segments, when the retina is stimulated by a light pulse. This effect can be used to monitor the activity of single cones in the living human eye. Objective monitoring of photoreceptor activity using such intrinsic optical signals could have important diagnostic applications in ophthalmology and neurology and might provide insight to facilitate basic research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
Wojtkowski, M., Srinivasan, V. J., Ko, T. H., Fujimoto, J. G., Kowalczyk, A., & Duker, J. S. (2004) · Optics Express · doi:10.1364/opex.12.002404 · Cited by 1,022 · cited 1×
“For this, an optimization algorithm (19, 25) removed the influence of dispersion and axial motion to obtain sharp OCT volumes.”
MethodPhotoreceptor loss in age-related macular degeneration.
Curcio, C. A., Medeiros, N. E., & Millican, C. L. (1996) · PubMed · Cited by 924
The retina in Parkinson's disease
Archibald, N. K., Clarke, M. P., Mosimann, U. P., & Burn, D. J. (2009) · Brain · doi:10.1093/brain/awp068 · Cited by 408
Bizheva, K. K., Pflug, R., Hermann, B., Považay, B., Sattmann, H., Qiu, P. S., Anger, E., Reitsamer, H. A., Popov, S. V., Taylor, J. R., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0506997103 · Cited by 231 · cited 2×
“Almost 10 years ago, weak changes in backscattering intensity after retinal stimulation were observed using OCT in vitro (10) and in animals (11).”
BackgroundComputational adaptive optics for broadband optical interferometric tomography of biological tissue
Adie, S. G., Graf, B. W., Ahmad, A., Carney, P. S., & Boppart, S. A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1121193109 · Cited by 209
Computational high-resolution optical imaging of the living human retina
Shemonski, N. D., South, F. A., Liu, Y.-Z., Adie, S. G., Carney, P. S., & Boppart, S. A. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.102 · Cited by 174 · cited 1×
“After this, single cone photoreceptors were resolvable (18, 19).”
BackgroundIn vivo functional imaging of human cone photoreceptors
Jonnal, R. S., Rha, J., Zhang, Y., Cense, B., Gao, W., & Miller, D. T. (2007) · Optics Express · doi:10.1364/oe.15.016141 · Cited by 169
Srinivasan, V. J., Wojtkowski, M., Fujimoto, J. G., & Duker, J. S. (2006) · Optics Letters · doi:10.1364/ol.31.002308 · Cited by 164
Cited by
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Roadmap on digital holography [Invited]
Javidi, B., Carnicer, A., Anand, A., Barbastathis, G., Chen, W., Ferraro, P., Goodman, J. W., Horisaki, R., Khare, K., Kujawinska, M., et al. (2021) · Optics Express · doi:10.1364/oe.435915 · Cited by 309
Adaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
High-speed OCT light sources and systems [Invited]
Klein, T., & Huber, R. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000828 · Cited by 220
Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited]
Pircher, M., & Zawadzki, R. J. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002536 · Cited by 209
Metadata
- Authors
- Hillmann, D., Spahr, H., Pfäffle, C., Sudkamp, H., Franke, G., & Hüttmann, G.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2016-10-11
- Volume
- 113
- Issue
- 46
- Pages
- 13138-13143
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2364913486
- Cited by
- 227
- References
- 22
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.