The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Electrochemical interrogation of conformational changes as a reagentless method for the sequence-specific detection of DNA
Open accessAbstract
We report a strategy for the reagentless transduction of DNA hybridization into a readily detectable electrochemical signal by means of a conformational change analogous to the optical molecular beacon approach. The strategy involves an electroactive, ferrocene-tagged DNA stem–loop structure that self-assembles onto a gold electrode by means of facile gold-thiol chemistry. Hybridization induces a large conformational change in this surface-confined DNA structure, which in turn significantly alters the electron-transfer tunneling distance between the electrode and the redoxable label. The resulting change in electron transfer efficiency is readily measured by cyclic voltammetry at target DNA concentrations as low as 10 pM. In contrast to existing optical approaches, an electrochemical DNA (E-DNA) sensor built on this strategy can detect femtomoles of target DNA without employing cumbersome and expensive optics, light sources, or photodetectors. In contrast to previously reported electrochemical approaches, the E-DNA sensor achieves this impressive sensitivity without the use of exogenous reagents and without sacrificing selectivity or reusability. The E-DNA sensor thus offers the promise of convenient, reusable detection of picomolar DNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Nanoparticles with Raman Spectroscopic Fingerprints for DNA and RNA Detection
Cao, Y. C., Jin, R., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.297.5586.1536 · Cited by 2,971
Characterization of DNA Probes Immobilized on Gold Surfaces
Herne, T. M., & Tarlov, M. J. (1997) · Journal of the American Chemical Society · doi:10.1021/ja9719586 · Cited by 1,541
Array-Based Electrical Detection of DNA with Nanoparticle Probes
Park, S.-J., Taton, T. A., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.1067003 · Cited by 1,515
Coupling of folding and binding for unstructured proteins
Dyson, H. J., & Wright, P. E. (2002) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(02)00289-0 · Cited by 1,327
DNA Microarray Technology: Devices, Systems, and Applications
Heller, M. J. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153438 · Cited by 1,068
Thermodynamic basis of the enhanced specificity of structured DNA probes
Bonnet, G., Tyagi, S., Libchaber, A., & Kramer, F. R. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.11.6171 · Cited by 658
Mutation detection by electrocatalysis at DNA-modified electrodes
Boon, E. M., Ceres, D. M., Drummond, T. G., Hill, M. G., & Barton, J. K. (2000) · Nature Biotechnology · doi:10.1038/80301 · Cited by 639
DNA detection using water-soluble conjugated polymers and peptide nucleic acid probes
Gaylord, B. S., Heeger, A. J., & Bazan, G. C. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.162375999 · Cited by 605
Self-citationSequence-selective biosensor for DNA based on electroactive hybridization indicators
Millan, K. M., & Mikkelsen, S. R. (1993) · Analytical Chemistry · doi:10.1021/ac00065a025 · Cited by 552
Single-base mismatch detection based on charge transduction through DNA
Kelley, S. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.24.4830 · Cited by 495
Electrochemical DNA Hybridization Biosensors
Gooding, J. J. (2002) · Electroanalysis · doi:10.1002/1521-4109(200209)14:17<1149::aid-elan1149>3.0.co;2-8 · Cited by 480
Electronic detection of DNA by its intrinsic molecular charge
Fritz, J., Cooper, E. B., Gaudet, S., Sorger, P. K., & Manalis, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232276699 · Cited by 443
Options available — from start to finish — for obtaining expression data by microarray
Bowtell, D. D. L. (1999) · Nature Genetics · doi:10.1038/4455 · Cited by 439
Hybridization of Mismatched or Partially Matched DNA at Surfaces
Peterson, A. W., Wolf, L. K., & Georgiadis, R. M. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0279996 · Cited by 406
Detection of single-base DNA mutations by enzyme-amplified electronic transduction
Patolsky, F., Lichtenstein, A., & Willner, I. (2001) · Nature Biotechnology · doi:10.1038/85704 · Cited by 368
Spectral Genotyping of Human Alleles
Kostrikis, L. G., Tyagi, S., Mhlanga, M. M., Ho, D. D., & Kramer, F. R. (1998) · Science · doi:10.1126/science.279.5354.1228 · Cited by 315
Biomaterials for Sensors, Fuel Cells, and Circuitry
Willner, I. (2002) · Science · doi:10.1126/science.298.5602.2407 · Cited by 312
Electronic Detection of Single-Base Mismatches in DNA with Ferrocene-Modified Probes
Yu, C. J., Wan, Y., Yowanto, H., Li, J., Tao, C., James, M. D., Tan, C. L., Blackburn, G. F., & Meade, T. J. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010045f · Cited by 260
Electronic Detection of Nucleic Acids
Umek, R. M., Lin, S. W., Vielmetter, J., Terbrueggen, R. H., Irvine, B., Yu, C. J., Kayyem, J. F., Yowanto, H., Blackburn, G. F., Farkas, D. H., et al. (2001) · The Journal of Molecular Diagnostics · doi:10.1016/s1525-1578(10)60655-1 · Cited by 253
Bednar, J., Furrer, P., Katritch, V., Stasiak, A., Dubochet, J., & Stasiak, A. (1995) · Journal of Molecular Biology · doi:10.1006/jmbi.1995.0640 · Cited by 250
In vitro selection of an allosteric ribozyme that transduces analytes to amplicons
Robertson, M. P., & Ellington, A. (1999) · Nature Biotechnology · doi:10.1038/5236 · Cited by 244
Fluorescence-based nucleic acid detection and microarrays
Epstein, J. R., Biran, I., & Walt, D. R. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(02)00030-2 · Cited by 223
Du, H., Disney, M. D., Miller, B. L., & Krauss, T. D. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0290781 · Cited by 222
Höök, F., Ray, A., Nordén, B., & Kasemo, B. (2001) · Langmuir · doi:10.1021/la0107704 · Cited by 217
Xu, X.-H., & Bard, A. J. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00114a027 · Cited by 190
Armistead, P. M., & Thorp, H. H. (2000) · Analytical Chemistry · doi:10.1021/ac000051e · Cited by 180
Electrochemistry of Nucleic Acids and Development of DNA Sensors
Paleček, E., & Jelen, F. (2002) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340290765560 · Cited by 165
The importance of being unfolded
Plaxco, K. W., & Groβ, M. (1997) · Nature · doi:10.1038/386657a0 · Cited by 121
Self-citationElectron tunneling in protein crystals
Tezcan, F. A., Crane, B. R., Winkler, J. R., & Gray, H. B. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.081072898 · Cited by 117
DNA Conformational Switches as Sensitive Electronic Sensors of Analytes
Fahlman, R. P., & Sen, D. (2002) · Journal of the American Chemical Society · doi:10.1021/ja012618u · Cited by 98
Hirst, J., Duff, J. L. C., Jameson, G. N. L., Kemper, M. A., Burgess, B. K., & Armstrong, F. A. (1998) · Journal of the American Chemical Society · doi:10.1021/ja980380c · Cited by 93
Chang, I., Lee, J. C., Winkler, J. R., & Gray, H. B. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0637283100 · Cited by 71
Molecular Beacons: Fluorogenic Probes for Living Cell Study
Fang, X., Mi, Y., Li, J. J., Beck, T., Schuster, S. M., & Tan, W. (2002) · Cell Biochemistry and Biophysics · doi:10.1385/cbb:37:2:071 · Cited by 65
[1] Fluorescence-based expression monitoring using microarrays
Winzeler, E. A., Schena, M., & Davis, R. W. (1999) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(99)06003-6 · Cited by 49
Cited by
Bioorganometallic Chemistry of Ferrocene
van Staveren, D. R., & Metzler-Nolte, N. (2004) · Chemical Reviews · doi:10.1021/cr0101510 · Cited by 1,319
DNA Biosensors and Microarrays
Sassolas, A., Leca-Bouvier, B. D., & Blum, L. J. (2008) · Chemical Reviews · doi:10.1021/cr0684467 · Cited by 1,246
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Electronic Aptamer‐Based Sensors
Willner, I., & Zayats, M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200604524 · Cited by 818
Label‐Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer‐Based Sensor
Xiao, Y., Lubin, A. A., Heeger, A. J., & Plaxco, K. W. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500989 · Cited by 812
Self-citation
Metadata
- Authors
- Fan, C., Plaxco, K. W., & Heeger, A. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2003-07-16
- Volume
- 100
- Issue
- 16
- Pages
- 9134-9137
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2035868441
- Cited by
- 1,043
- References
- 35
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.