Syringe-injectable mesh electronics integrate seamlessly with minimal chronic immune response in the brain
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Significance: Seamless integration of electrical probes within neural tissue could substantially enhance their impact and open up new opportunities in neuroscience research through electronic therapeutics. This paper describes systematic studies of brain tissue behavior following implantation of a design for probes that can be precisely targeted to specific brain regions by syringe injection as in many biological species and have an ultraflexible open mesh structure similar to brain tissue itself. Studies of the chronic tissue response postimplantation demonstrate that these tissue-like probes do not elicit inflammation or scarring, in contrast to more conventional probes. Moreover, neurons were found to penetrate through the probes’ open mesh structure, thus demonstrating an unprecedented level of integration and compatibility with the brain circuitry.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As another representative type of flexible structures, the mesh structure also distinguishes it for both inserted and superficial neural implants owing to its stretchability and adaptability.[301,348–350]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [349]
In the citing paper
“Very small implants—with dimensions smaller than individual cells—such as injectable mesh electrodes seem to generate minimal amounts of FBR, potentially largely bypassing this response by preventing cells (neutrophils, macrophages and fibroblasts in Figure 1) from fully spreading on their surface and becoming activated (Zhou et al., 2017).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Zhou et al., 2017
Citations
Cites
Cluster failure: why fMRI inferences for spatial extent have inflated false-positive rates
Eklund, A., Nichols, T. E., & Knutsson, H. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1602413113 · Cited by 3,487 · cited 1×
“For example, fMRI (4, 5) has the ability to map whole-brain activity, although low spatiotemporal resolution (6) precludes monitoring neural circuits at the cellular level.”
BackgroundReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“The capability to section the brain tissue with embedded probes enables clear cellular-scale visualization of the tissue–electronics interface, in contrast to more rigid probes that must be removed before sectioning (16).”
BackgroundCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Injectable, Cellular-Scale Optoelectronics with Applications for Wireless Optogenetics
Kim, T.-I., McCall, J. G., Jung, Y. H., Huang, X., Siuda, E. R., Li, Y., Song, J., Song, Y. M., Pao, H. A., Kim, R.-H., et al. (2013) · Science · doi:10.1126/science.1232437 · Cited by 1,174 · cited 4×
“2 E and F) maintain the substantial accumulation of astrocytes and depletion of neuron somata around the thin film that is consistent with glial scarring (30, 32).”
BackgroundMethodResultInfluentialViventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
NeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
All-optical electrophysiology in mammalian neurons using engineered microbial rhodopsins
Hochbaum, D. R., Zhao, Y., Farhi, S. L., Klapoetke, N., Werley, C. A., Kapoor, V., Zou, P., Kralj, J. M., Maclaurin, D., Smedemark-Margulies, N., et al. (2014) · Nature Methods · doi:10.1038/nmeth.3000 · Cited by 770
From the neuron doctrine to neural networks
Yuste, R. (2015) · Nature Reviews Neuroscience · doi:10.1038/nrn3962 · Cited by 754
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721
Research works printed but not linked: 1
- PS Steif Mechanics of Materials (Pearson, Upper Saddle River, NJ, 2012).
Cited by
Items 201–226 of 226
Songbird organotypic culture as an in vitro model for interrogating sparse sequencing networksPreprint
Shen, J., Blute, T. A., Liberti, W. A., Yen, W., Liberti, D. C., Kotten, D. N., Cruz‐Martín, A., & Gardner, T. J. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/164228 · Cited by 1
Biomimicry for Injectable Mesh Nanoelectronics
Clayton, C., & Tian, B. (2019) · Bioelectronics in Medicine · doi:10.2217/bem-2019-0017 · Cited by 1
Zhou, X., Zhang, W., & Xie, J. (2020) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-020-2243-7
Zaidi, S. M. T., Kocatürk, S., Baykaş, T., & Kocatürk, M. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.01.24.427325
Tethered brain: disentangling unintentional brain-mesh interfaces. Illustrative case
Spellicy, S. E., Kilianski, J. R., Poston, R., Moore‐Hill, D., & Vale, F. Ĺ. (2021) · Journal of Neurosurgery Case Lessons · doi:10.3171/case21183
Neuroflex: Intraneural and Extraneural Flexible Sensor Architectures for Neural Probing
Patil, A. C., & Thakor, N. V. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_16-2
Fain, G. (2018) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.733517434.793549140
State-of-the-Art Technology on Highly Miniaturized Free-Floating Neural Implants
Khalifa, A., & Etienne‐Cummings, R. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_114-1 · Cited by 1
Neuroflex: Intraneural and Extraneural Flexible Sensor Architectures for Neural Probing
Patil, A. C., & Thakor, N. V. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_16
3D Printable Hydrogel Bioelectronic Interfaces for Various Organs
Zhou, T. (2023) · IEEE International Flexible Electronics Technology Conference (IFETC) · doi:10.1109/ifetc57334.2023.10254791
Self-citationFlexible intracortical probes for stable neural recording: from the perspective of structure
Wang, S., Jiang, Q., & Song, J. (2024) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ad71dc
“Time-dependent histology studies were performed to investigate the chronic foreign body responses of the mesh probes [91].”
Romanov, A. O., Migalev, A. S., Кириллова, Д. А., Magaramov, R. N., Rybakova, A. V., Trashkov, A. P., & Gotovtsev, P. M. (2024) · Nanobiotechnology Reports · doi:10.1134/s2635167624600743
Self-Assembled Ultra-Flexible Mesh Probes for Stable Neural Recordings
Tu, K., Wang, L., Yang, B. T., & Liu, J. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10917865
Trends in Tissue-Interfaced Electronics toward Advanced Healthcare
Fujita, H., & Fujie, T. (2022) · Journal of The Adhesion Society of Japan · doi:10.11618/adhesion.58.184
Leccardi, M. J. I. A., Desbiolles, B. X. E., Yadav, S., Yu, Y., & Sarkar, D. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-01117-9
“Other approaches to reducing invasiveness and achieving minimal damage to the surrounding tissue include fi bers-based 19,20 and mesh electronics 21 – 23 , as they minimize the footprint of the implants.”
Nguyen, E., Barkóczi, B., Horváth, C., Judák, L., Rózsa, B. J., Ceyssens, F., Ulbert, I., Wittner, L., Schelles, M., & Fiáth, R. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.02.09.704741
“…probes fabricated from softer, flexible materials (e.g., polyimide, SU-8, or Parylene C) may mitigate neuronal damage and the foreign body response, enabling more reliable results in chronic studies (He et al., 2020; Lycke et al., 2023; Orlemann et al., 2024; Zhao et al., 2023; Zhou et al., 2017).”
A multi-region flexible neural interface for behavioral state decoding in freely moving mice
Tian, Y., Li, G., Su, H., Jiang, L., Luo, Y., Yang, Y., Huang, L., Li, J., Jin, S., Chen, P., et al. (2026) · Microsystems & Nanoengineering · doi:10.1038/s41378-026-01258-5 · Cited by 1
“Although fl exible probes have improved surgical accessibility and recording stability, their potential for brain-wide recording remains largely unrealized 37 – 39 .”
Advances in Biomaterials for Flexible Implantable Sensors & Bioelectronics
Bateman, A., & Yeo, W. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-30151-3.00010-3 · Cited by 1
Gu, W., Ju, J., & Wang, L. (2026) · Small · doi:10.1002/smll.74206
Kim, W., Kim, Y., Yoo, H., & Lee, E. K. (2026) · Discover Nano · doi:10.1186/s11671-026-04790-5 · Cited by 2
“3.2 integrate chemical sensing, mechanical sensing of intraocular pressure, and optical output on a single transparent elastomeric substrate, demonstrating that multimodal integration is achievable even in highly space-constrained implantable formats [203, 204].”
InfluentialAI-integrated closed-loop brain-machine interfaces using soft bioelectronics
Kim, S., Kim, D., & Son, D. (2026) · Biomedical Engineering Letters · doi:10.1007/s13534-026-00606-8
“2a(i) and (ii)) [57, 58].”
He, Z., Ma, J., Liu, Y., & Du, Z. J. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27156752 · Cited by 2
“Direct comparison across device geometries, brain regions, implantation routes, observation periods, and histological or electrophysiological endpoints remains necessary before these findings can be generalized to other chronic neural interfaces [71,78].”
Lee, H., Wang, X., Li, S., Park, J., Lee, H., Yao, J., Narayan, K., Wang, Y., Ren, J., Deng, Y., et al. (2026) · Advanced Functional Materials · doi:10.1002/adfm.78720
“Recent progress has introduced various flexible neural probes [ 17–26 ], which have demonstrated reduced foreign body responses and glial scarring when compared to rigid neural sensors, providing better platforms for neural recording and modulation [ 14, 27, 28 ].”
Self-citationA biohybrid mesh harvester for distributed energy harvesting in living tissues
Wang, S., Wang, X., Fu, S., Senger, C., Pfund, J. D., Jain, M., Katsumata, R., & Yao, J. (2026) · Science Advances · doi:10.1126/sciadv.aei5963
Guo, L. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/aeb442
“Although the nanoES was originally envisioned as a ‘smart implantable biomaterial,’ subsequent studies from the same group focused on implanting the mesh electronics alone (without the tissue component) into rat cortex as a minimally invasive brain probe [57–59].”
Zhao, C., Sun, Z., Wang, S., Wang, B., Yuan, Z., Guo, Y., Zhao, J., Li, L., Wang, X., Jiang, W., et al. (2026) · InfoMat · doi:10.1002/inf2.70195
Metadata
- Authors
- Zhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M.
- Affiliations
- Harvard University (US)
- Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA 02138;
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2017-05-22
- Volume
- 114
- Issue
- 23
- Pages
- 5894-5899
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC5468665
- OpenAlex
- W2620547429
- Semantic Scholar
- 32b9c6f9254a9311f61faf3ec3563f22b125c043
- Cited by
- 227
- References
- 44
- Citations by year
- 2026: 22 · 2025: 14 · 2024: 20 · 2023: 23 · 2022: 18 · 2021: 45 · 2020: 29 · 2019: 32 · 2018: 14 · 2017: 9
- FWCI
- 11.25
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Fidelity Investments | Fidelity Biosciences (A25744)
- American Heart Association (16POST27250219)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- gliosis, astrocytes, microglia, histology
- MeSH terms
- Animals, Brain, Brain Mapping, Electrodes, Implanted, Male, Mice, Inbred C57BL, Microscopy, Fluorescence, Syringes, Mice, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.