Closed-loop control of targeted ultrasound drug delivery across the blood–brain/tumor barriers in a rat glioma model
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Significance: Focused ultrasound is currently the only method of reversible blood–brain barrier disruption for targeted drug delivery without incision or radiation. A significant challenge for its clinical translation is a lack of reliable real-time treatment control. Here a closed-loop, real-time control paradigm is shown capable of sustaining stable microbubble oscillations at a preset level while minimizing microbubble behavior that may result in vascular damage. Tested at clinically relevant frequency in healthy and tumor-bearing rats, our approach enables targeted delivery of predefined drug concentrations within a therapeutically effective range in both normal tissue and glioma, while maintaining a safe exposure level. It can be readily implemented clinically for delivering chemotherapeutics or other agents and potentially applied to other cavitation-enhanced ultrasound therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Immunotherapy of Diffuse Gliomas: Biological Background, Current Status and Future Developments
Grauer, O. M., Wesseling, P., & Adema, G. J. (2009) · Brain Pathology · doi:10.1111/j.1750-3639.2009.00315.x · Cited by 4,007
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
Self-citationA Pilot Study of Focused Ultrasound Thalamotomy for Essential Tremor
Elias, W. J., Huss, D., Voss, T., Loomba, J., Khaled, M., Zadicario, E., Frysinger, R. C., Sperling, S. A., Wylie, S., Monteith, S. J., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1300962 · Cited by 875
Clinical trial of blood-brain barrier disruption by pulsed ultrasound
Carpentier, A., Canney, M., Vignot, A., Reina, V., Beccaria, K., Horodyckid, C., Karachi, C., Leclercq, D., Lafon, C., Chapelon, J.-Y., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6086 · Cited by 757
McDannold, N., Arvanitis, C. D., Vykhodtseva, N., & Livingstone, M. S. (2012) · Cancer Research · doi:10.1158/0008-5472.can-12-0128 · Cited by 588
Self-citationDisrupting the blood–brain barrier by focused ultrasound induces sterile inflammation
Kovacs, Z. I., Kim, S., Jikaria, N., Qureshi, F., Milo, B., Lewis, B. K., Bresler, M., Burks, S. R., & Frank, J. A. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1614777114 · Cited by 458
McDannold, N., Vykhodtseva, N., & Hynynen, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/4/003 · Cited by 447
Self-citationAryal, M., Arvanitis, C. D., Alexander, P. M., & McDannold, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.01.008 · Cited by 443
Self-citationBarth, R. F., & Kaur, B. (2009) · Journal of Neuro-Oncology · doi:10.1007/s11060-009-9875-7 · Cited by 427
O’Reilly, M. A., & Hynynen, K. (2012) · Radiology · doi:10.1148/radiol.11111417 · Cited by 401
Cited by
The blood–brain barrier and blood–tumour barrier in brain tumours and metastases
Arvanitis, C. D., Ferraro, G. B., & Jain, R. K. (2020) · Nature Reviews Cancer · doi:10.1038/s41568-019-0205-x · Cited by 1,792
Large-scale generation of functional mRNA-encapsulating exosomes via cellular nanoporation
Yang, Z., Shi, J., Xie, J., Wang, Y., Sun, J., Liu, T., Zhao, Y., Zhao, X., Wang, X., Ma, Y., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0485-1 · Cited by 744
Emerging therapies for glioblastoma: current state and future directions
Rong, L., Li, N., & Zhang, Z. (2022) · Journal of Experimental & Clinical Cancer Research · doi:10.1186/s13046-022-02349-7 · Cited by 510
Ultrasound-Responsive Cavitation Nuclei for Therapy and Drug Delivery
Kooiman, K., Roovers, S., Langeveld, S. A. G., Kleven, R. T., Dewitte, H., O'Reilly, M. A., Escoffre, J.-M., Bouakaz, A., Verweij, M. D., Hynynen, K., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2020.01.002 · Cited by 359
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Roovers, S., Segers, T., Lajoinie, G., Deprez, J., Versluis, M., De Smedt, S. C., & Lentacker, I. (2019) · Langmuir · doi:10.1021/acs.langmuir.8b03779 · Cited by 256
Opening doors with ultrasound and microbubbles: Beating biological barriers to promote drug delivery
Deprez, J., Lajoinie, G., Engelen, Y., De Smedt, S. C., & Lentacker, I. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.02.015 · Cited by 207
Ultrasound-responsive polymer-based drug delivery systems
Wei, P., Cornel, E. J., & Du, J. (2021) · Drug Delivery and Translational Research · doi:10.1007/s13346-021-00963-0 · Cited by 188
State-of-the-art of microbubble-assisted blood-brain barrier disruption
Song, K.-H., Harvey, B. K., & Borden, M. A. (2018) · Theranostics · doi:10.7150/thno.26869 · Cited by 184
“in 2017, under the assumption that inertial cavitation would cause tissue damage, and that stable cavitation was favorable [16,17] .”
BackgroundUltrasound-mediated nano drug delivery for treating cancer: Fundamental physics to future directions
Moradi Kashkooli, F., Jakhmola, A., Hornsby, T. K., Tavakkoli, J. (., & Kolios, M. C. (2023) · Journal of Controlled Release · doi:10.1016/j.jconrel.2023.02.009 · Cited by 177
Anastasiadis, P., Gandhi, D., Guo, Y., Ahmed, A.-K., Bentzen, S. M., Arvanitis, C., & Woodworth, G. F. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2103280118 · Cited by 175
“, bubble collapse and/or tissue damage) (17, 18).”
Control and Autonomy of Microrobots: Recent Progress and Perspective
Jiang, J., Yang, Z., Ferreira, A., & Zhang, L. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100279 · Cited by 173
Wang, J., Li, Z., Pan, M., Fiaz, M., Hao, Y., Yan, Y., Sun, L., & Yan, F. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114539 · Cited by 161
Tanaka, M., Araujo, A. C., Valenti, V. E., Guiguer, E. L., Catharin, V. C. S., Gualhardi, C. M., de Souza Bastos Mazuqueli Pereira, E., de Alvares Goulart, R., de Argolo Haber, R. S., de Carvalho, A. C. A., et al. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27052370 · Cited by 13
Metadata
- Authors
- Sun, T., Zhang, Y., Power, C., Alexander, P. M., Sutton, J. T., Aryal, M., Vykhodtseva, N., Miller, E. L., & McDannold, N. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2017-11-13
- Volume
- 114
- Issue
- 48
- Pages
- E10281-E10290
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2768295381
- Cited by
- 258
- References
- 45
- FWCI
- 11.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.