The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Laminar specificity of functional MRI onset times during somatosensory stimulation in rat
Open accessAbstract
The blood oxygenation level-dependent (BOLD) response to somatosensory stimulation was measured in α-chloralose-anesthetized rats. BOLD fMRI was obtained at 40-ms temporal resolution and spatial resolution of 200 × 200 × 2,000 μm 3 by using a gated activation paradigm in an 11.7 T MRI. Results show a consistent heterogeneity of fMRI onset times and amplitudes. The earliest onset time (0.59 ± 0.17 s, n = 9) corresponded anatomically to layer IV, with superficial and deeper layers starting significantly later (1.27 ± 0.43 s in layers I–III, and 1.11 ± 0.45 s in layer VI). The amplitude of BOLD signal changes also varied with the cortical depth from the pial surface. Changes in the supragranular layers (8.3%) were 44% bigger than changes in the intermediate layers (5.5%), located only ≈700 μm below, and 144% larger than the bottom layer (3.5%), located ≈1.4 mm below the pial surface. The data presented demonstrate that BOLD signal changes have distinct amplitude and temporal characteristics, which vary spatially across cortical layers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Rat Brain in Stereotaxic Coordinates
(1982) · Elsevier eBooks · doi:10.1016/c2009-0-63235-9 · Cited by 51,963
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551
AChE-stained horizontal sections of the rat brain in stereotaxic coordinates
Paxinos, G., Watson, C. R. R., & Emson, P. C. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90021-7 · Cited by 4,497
Paxinos, G. (1985) · Cited by 3,715
The structural organization of layer IV in the somatosensory region (S I) of mouse cerebral cortex
Woolsey, T. A., & Van der Loos, H. (1970) · Brain Research · doi:10.1016/0006-8993(70)90079-x · Cited by 2,254
Event-Related fMRI: Characterizing Differential Responses
Friston, K. J., Fletcher, P., Josephs, O., Holmes, A., Rugg, M. D., & Turner, R. (1998) · NeuroImage · doi:10.1006/nimg.1997.0306 · Cited by 2,029
Processing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763
Malonek, D., & Grinvald, A. (1996) · Science · doi:10.1126/science.272.5261.551 · Cited by 1,097
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Cited by
The Neurovascular Unit Coming of Age: A Journey through Neurovascular Coupling in Health and Disease
Iadecola, C. (2017) · Neuron · doi:10.1016/j.neuron.2017.07.030 · Cited by 2,480
Neurovascular regulation in the normal brain and in Alzheimer's disease
Iadecola, C. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1387 · Cited by 2,213
Tsai, P. S., Kaufhold, J. P., Blinder, P., Friedman, B., Drew, P. J., Karten, H. J., Lyden, P. D., & Kleinfeld, D. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.3287-09.2009 · Cited by 572
Laminar analysis of 7T BOLD using an imposed spatial activation pattern in human V1
Polimeni, J. R., Fischl, B., Greve, D. N., & Wald, L. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.005 · Cited by 431
The fMRI signal, slow cortical potential and consciousness
He, B. J., & Raichle, M. E. (2009) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2009.04.004 · Cited by 332
Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla
Shmuel, A., Yacoub, E., Chaimow, D., Logothetis, N. K., & Ugurbil, K. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.12.030 · Cited by 294
Tian, P., Teng, I. C., May, L. D., Kurz, R., Lu, K., Scadeng, M., Hillman, E. M. C., De Crespigny, A. J., D’Arceuil, H. E., Mandeville, J. B., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006735107 · Cited by 293
Hillman, E. M. C., Devor, A., Bouchard, M. B., Dunn, A. K., Krauss, G. W., Skoch, J., Bacskai, B. J., Dale, A. M., & Boas, D. A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.032 · Cited by 289
Anesthesia and the Quantitative Evaluation of Neurovascular Coupling
Masamoto, K., & Kanno, I. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.50 · Cited by 273
In vivo detection of neuroarchitecture in the rodent brain using manganese-enhanced MRI
Aoki, I., Wu, Y.-J. L., Silva, A. C., Lynch, R. M., & Koretsky, A. P. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.03.031 · Cited by 269
Self-citationThe future of ultra-high field MRI and fMRI for study of the human brain
Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.065 · Cited by 261
Ultrahigh field magnetic resonance imaging and spectroscopy
Uğurbil, K., Adriany, G., Andersen, P., Chen, W., Garwood, M., Gruetter, R., Henry, P.-G., Kim, S.-G., Lieu, H., Tkac, I., et al. (2003) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.08.027 · Cited by 252
Layer-specific BOLD activation in human V1
Koopmans, P. J., Barth, M., & Norris, D. G. (2010) · Human Brain Mapping · doi:10.1002/hbm.20936 · Cited by 220
Mangia, S., Giove, F., Tkáč, I., Logothetis, N. K., Henry, P.-G., Olman, C. A., Maraviglia, B., Di Salle, F., & Uğurbil, K. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.134 · Cited by 161
“…resolutions in the range of 0.15 0.15 2 mm3 (Fukuda et al, 2006; Harel et al, 2006; Logothetis et al, 2002, and references therein), 0.2 0.2 2 mm3 (Silva and Koretsky, 2002), or 0.2 0.2 0.2 mm3 (Kida et al, 2002) can be reached in high field animal studies, and up to 0.5 0.5 2 mm3 in high-field…”
InfluentialMagnetic Field Modeling with a Set of Individual Localized Coils
Juchem, C., Nixon, T. W., McIntyre, S., Rothman, D. L., & Graaf, R. A. D. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.03.008 · Cited by 91
Febo, M. (2011) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2011.00043 · Cited by 43
A rapid-onset diffusion functional MRI signal reflects neuromorphological coupling dynamics
Nunes, D., Gil, R., & Shemesh, N. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117862 · Cited by 43
Metadata
- Authors
- Silva, A. C., & Koretsky, A. P.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-10-29
- Volume
- 99
- Issue
- 23
- Pages
- 15182-15187
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1991831794
- Cited by
- 269
- References
- 56
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.