Microfluidic tectonics: A comprehensive construction platform for microfluidic systems
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A microfluidic platform for the construction of microscale components and autonomous systems is presented. The platform combines liquid-phase photopolymerization, lithography, and laminar flow to allow the creation of complex and autonomous microfluidic systems. The fabrication of channels, actuators, valves, sensors, and systems is demonstrated. Construction times can be as short as 10 min, providing ultrarapid prototyping of microfluidic systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon polymerization initiators for three-dimensional optical data storage and microfabrication
Cumpston, B. H., Ananthavel, S. P., Barlow, S., Dyer, D. L., Ehrlich, J. E., Erskine, L. L., Heikal, A. A., Kuebler, S. M., Lee, I.-Y. S., McCord-Maughon, D., et al. (1999) · Nature · doi:10.1038/17989 · Cited by 2,232
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Self-citationMicromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,200
Three-dimensional micro-channel fabrication in polydimethylsiloxane (PDMS) elastomer
Jo, B.-H., Van Lerberghe, L. M., Motsegood, K. M., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.825780 · Cited by 1,098
Self-citationMicrofabrication Inside Capillaries Using Multiphase Laminar Flow Patterning
Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Science · doi:10.1126/science.285.5424.83 · Cited by 659
Controlled Folding of Micrometer-Size Structures
Smela, E., Inganäs, O., & Lundström, I. (1995) · Science · doi:10.1126/science.268.5218.1735 · Cited by 586
Two-photon-absorbed near-infrared photopolymerization for three-dimensional microfabrication
Maruo, S., & Kawata, S. (1998) · Journal of Microelectromechanical Systems · doi:10.1109/84.735349 · Cited by 217
Cited by
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Bioinspired Surfaces with Special Wettability
Sun, T., Feng, L., Gao, X., & Jiang, L. (2005) · Accounts of Chemical Research · doi:10.1021/ar040224c · Cited by 2,044
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Self-citationDeveloping optofluidic technology through the fusion of microfluidics and optics
Psaltis, D., Quake, S. R., & Yang, C. (2006) · Nature · doi:10.1038/nature05060 · Cited by 1,733
Reversible Switching between Superhydrophilicity and Superhydrophobicity
Sun, T., Wang, G., Feng, L., Liu, B., Ma, Y., Jiang, L., & Zhu, D. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200352565 · Cited by 1,128
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Surface-Directed Liquid Flow Inside Microchannels
Zhao, B., Moore, J. S., & Beebe, D. J. (2001) · Science · doi:10.1126/science.291.5506.1023 · Cited by 765
Self-citationHydrogel-based actuators: possibilities and limitations
Ionov, L. (2014) · Materials Today · doi:10.1016/j.mattod.2014.07.002 · Cited by 680
Flexible Methods for Microfluidics
Whitesides, G. M., & Stroock, A. D. (2001) · Physics Today · doi:10.1063/1.1387591 · Cited by 595
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
Fabrication of Poly(ethylene glycol) Hydrogel Microstructures Using Photolithography
Revzin, A., Russell, R. J., Yadavalli, V. K., Koh, W.-G., Deister, C., Hile, D. D., Mellott, M. B., & Pishko, M. V. (2001) · Langmuir · doi:10.1021/la010075w · Cited by 472
Biomimetic Hydrogel‐Based Actuating Systems
Ionov, L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203692 · Cited by 469
Ziaie, B. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.09.001 · Cited by 456
An Integrated Fluorescence Detection System in Poly(dimethylsiloxane) for Microfluidic Applications
Chabinyc, M. L., Chiu, D. T., McDonald, J. C., Stroock, A. D., Christian, J. F., Karger, A. M., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac010423z · Cited by 419
Point-of-care microfluidic devices for pathogen detection
Nasseri, B., Soleimani, N., Rabiee, N., Kalbasi, A., Karimi, M., & Hamblin, M. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.050 · Cited by 382
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Protein immobilization techniques for microfluidic assays
Kim, D., & Herr, A. E. (2013) · Biomicrofluidics · doi:10.1063/1.4816934 · Cited by 376
Fabrication of PLGA scaffolds using soft lithography and microsyringe deposition
Vozzi, G., Flaim, C., Ahluwalia, A., & Bhatia, S. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00052-8 · Cited by 373
Dual‐Responsive Surfaces That Switch between Superhydrophilicity and Superhydrophobicity
Xia, F., Feng, L., Wang, S., Sun, T., Song, W., Jiang, W., & Jiang, L. (2006) · Advanced Materials · doi:10.1002/adma.200501772 · Cited by 344
Bartolo, D., Degré, G., Nghe, P., & Studer, V. (2008) · Lab Chip · doi:10.1039/b712368j · Cited by 265
Responsive biomimetic hydrogel valve for microfluidics
Yu, Q., Bauer, J. M., Moore, J. S., & Beebe, D. J. (2001) · Applied Physics Letters · doi:10.1063/1.1367010 · Cited by 262
Self-citationA microfluidic actuator based on thermoresponsive hydrogels
Harmon, M. E., Tang, M., & Frank, C. W. (2003) · Polymer · doi:10.1016/s0032-3861(03)00463-4 · Cited by 261
Direct nanoprinting by liquid-bridge-mediated nanotransfer moulding
Hwang, J. K., Cho, S., Dang, J. M., Kwak, E. B., Song, K., Moon, J., & Sung, M. M. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.175 · Cited by 177
Rahman, M. T., Barikbin, Z., Badruddoza, A. Z. M., Doyle, P. S., & Khan, S. A. (2013) · Langmuir · doi:10.1021/la401613w · Cited by 76
Metadata
- Authors
- Beebe, D. J., Moore, J. S., Yu, Q., Liu, R. H., Kraft, M. L., Jo, B.-H., & Devadoss, C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2000-11-21
- Volume
- 97
- Issue
- 25
- Pages
- 13488-13493
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2065293530
- Cited by
- 353
- References
- 7
- FWCI
- 20.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.