The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Two distinct Ca-dependent K currents in bullfrog sympathetic ganglion cells.
Open accessAbstract
Healthy bullfrog sympathetic ganglion cells often show a two-component afterhyperpolarization (AHP). Both components can be reduced or abolished by adding Ca-channel blockers or by removing external Ca. Application of a single electrode "hybrid clamp"--i.e., switching from current- to voltage-clamp at the peak of the AHP, reveals that the slow AHP component is generated by a small, slow, monotonically decaying outward current, which we call IAHP. IAHP is blocked by Ca-removal or by apamin and is a pure K current. It is slightly sensitive to muscarine and to tetraethylammonium ion but is much less so than muscarine-sensitive (IM) and fast Ca-dependent (IC) K currents. It also can be recorded in dual-electrode voltage-clamp experiments, where it is seen as a slow, small component of the outward tail current that follows brief depolarizations to 0 mV or beyond. IC is seen as an early, fast, large component of the same tail current. Both components are blocked by Ca removal, but only the IC component is blocked by low doses of tetraethylammonium ion. Thus, bullfrog ganglion cells exhibit two quite distinct Ca-dependent K currents, which differ in size, voltage-sensitivity, kinetics, and pharmacology. These two currents also play quite separate roles in shaping the action potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A calcium-activated hyperpolarization follows repetitive firing in hippocampal neurons
Hotson, J. R., & Prince, D. A. (1980) · Journal of Neurophysiology · doi:10.1152/jn.1980.43.2.409 · Cited by 569
Cole, A. E., & Nicoll, R. A. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015285 · Cited by 353
Self-citation
Cited by
Diversity and ubiquity of K channels
Rudy, B. (1988) · Neuroscience · doi:10.1016/0306-4522(88)90033-4 · Cited by 1,312
Variability, compensation and homeostasis in neuron and network function
Marder, E., & Goaillard, J.-M. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1949 · Cited by 1,212
McCormick, D. A. (1992) · Progress in Neurobiology · doi:10.1016/0301-0082(92)90012-4 · Cited by 1,117
Calcium-activated potassium channels
Vergara, C., Latorre, R., Marrion, N. V., & Adelman, J. P. (1998) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(98)80056-1 · Cited by 954
Chapter 12 Potassium currents in hippocampal pyramidal cells
Storm, J. F. (1990) · Progress in Brain Research · doi:10.1016/s0079-6123(08)61248-0 · Cited by 743
Metadata
- Authors
- Pennefather, P., Lancaster, B., Adams, P. R., & Nicoll, R. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1985-05
- Volume
- 82
- Issue
- 9
- Pages
- 3040-3044
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1979287010
- Cited by
- 415
- References
- 2
- FWCI
- 14.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two distinct Ca-dependent K currents in bullfrog sympathetic ganglion cells. https://app.cochat.ai/papers/10.1073/pnas.82.9.3040
- The paper
- Pennefather, P., Lancaster, B., Adams, P. R., & Nicoll, R. A. (1985). Two distinct Ca-dependent K currents in bullfrog sympathetic ganglion cells. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.82.9.3040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.