The DOI matches its Crossref record.
Fourier-transform mass spectrometry of large molecules by electrospray ionization.
Open accessAbstract
The multiply charged ions produced by electrospray ionization of peptides of molecular masses up to 29 kDa have been successfully introduced into a Fourier transform mass spectrometer of unique capabilities for tandem mass spectrometry, large ion dissociation, and resolution. Electrospray ionization places an unusually high number of charges on a peptide yielding mass/charge (m/z) values of 600-1500; in this range at normal operating pressures (approximately 10(-9) torr; 1 torr = 133.3 Pa) Fourier-transform mass spectrometry resolving power is greater than 100,000. Although only 10(-7) torr pressure has been obtained with the initial interface, the resulting resolving power of 5000 makes possible the resolution of isotopic peaks of multiply charged ions. Mass measuring accuracies of a few daltons for molecular masses up to 17 kDa have also been achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
The role of electron capture dissociation in biomolecular analysis
Cooper, H. J., Håkansson, K., & Marshall, A. G. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20014 · Cited by 514
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
“ESI-FT-ICR was first used for the analysis of intact proteins in 1989, with the detection of multiple charge states on a single protein, allowing for intact mass determination [80].”
MethodSenko, M. W., Hendrickson, C. L., Emmett, M. R., Shi, S. D. H., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(97)00126-8 · Cited by 462
Senko, M. W., Beu, S. C., & McLaffertycor, F. W. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00017-8 · Cited by 451
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Sampson, J. S., Hawkridge, A. M., & Muddiman, D. C. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.08.003 · Cited by 375
Mopper, K., Stubbins, A., Ritchie, J. D., Bialk, H. M., & Hatcher, P. G. (2007) · Chemical Reviews · doi:10.1021/cr050359b · Cited by 368
Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Self-citationRapid, sensitive analysis of protein mixtures by mass spectrometry.
Beavis, R. C., & Chait, B. T. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.17.6873 · Cited by 301
Milestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Chip-based genotyping by mass spectrometry
Tang, K., Fu, D.-J., Julien, D., Braun, A., Cantor, C. R., & Köster, H. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10016 · Cited by 286
Proteins in Art, Archaeology, and Paleontology: From Detection to Identification
Dallongeville, S., Garnier, N., Rolando, C., & Tokarski, C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00037 · Cited by 172
Metadata
- Authors
- Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1989-12
- Volume
- 86
- Issue
- 23
- Pages
- 9075-9078
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2007196896
- Cited by
- 215
- References
- 0
- FWCI
- 12.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.