Structural changes in hemoglobin during adsorption to solid surfaces: Effects of pH, ionic strength, and ligand binding
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
We have studied the adsorption of two structurally similar forms of hemoglobin (met-Hb and HbCO) to a hydrophobic self-assembled methyl-terminated thiol monolayer on a gold surface, by using a Quartz Crystal Microbalance (QCM) technique. This technique allows time-resolved simultaneous measurements of changes in frequency ( f ) (c.f. mass) and energy dissipation (D) (c.f. rigidity/viscoelastic properties) of the QCM during the adsorption process, which makes it possible to investigate the viscoelastic properties of the different protein layers during the adsorption process. Below the isoelectric points of both met-Hb and HbCO, the Δ D vs. Δ f graphs displayed two phases with significantly different slopes, which indicates two states of the adsorbed proteins with different visco-elastic properties. The slope of the first phase was smaller than that of the second phase, which indicates that the first phase was associated with binding of a more rigidly attached, presumably denatured protein layer, whereas the second phase was associated with formation of a second layer of more loosely bound proteins. This second layer desorbed, e.g., upon reduction of Fe 3+ of adsorbed met-Hb and subsequent binding of carbon monoxide (CO) forming HbCO. Thus, the results suggest that the adsorbed proteins in the second layer were in a native-like state. This information could only be obtained from simultaneous, time-resolved measurements of changes in both D and f , demonstrating that the QCM technique provides unique information about the mechanisms of protein adsorption to solid surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Tanford, C. (1968) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60401-5 · Cited by 2,130
Rodahl, M., Höök, F., Krozer, A., Brzezinski, P., & Kasemo, B. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145396 · Cited by 1,296
Self-citationIntermolecular and Surface Forces
(2011) · doi:10.1016/c2009-0-21560-1 · Cited by 871
Protein adsorption and materials biocompatibility: A tutorial review and suggested hypotheses
Andrade, J. D., & Hlady, V. (1986) · Advances in Polymer Science · doi:10.1007/3-540-16422-7_6 · Cited by 810
Höök, F., Rodahl, M., Brzezinski, P., & Kasemo, B. (1998) · Langmuir · doi:10.1021/la970815u · Cited by 724
Self-citationIn Situ Interfacial Mass Detection with Piezoelectric Transducers
Ward, M. D., & Buttry, D. A. (1990) · Science · doi:10.1126/science.249.4972.1000 · Cited by 525
Nanotribology of a Kr monolayer: A quartz-crystal microbalance study of atomic-scale friction
Krim, J., Solina, D. H., & Chiarello, R. (1991) · Physical Review Letters · doi:10.1103/physrevlett.66.181 · Cited by 425
On the measurement of thin liquid overlayers with the quartz-crystal microbalance
Rodahl, M., & Kasemo, B. (1996) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)80002-7 · Cited by 345
Self-citationRodahl, M., Höök, F., & Kasemo, B. (1996) · Analytical Chemistry · doi:10.1021/ac951203m · Cited by 339
Self-citationDriving forces for protein adsorption at solid surfaces
Norde, W. (1996) · Macromolecular Symposia · doi:10.1002/masy.19961030104 · Cited by 243
The Piezoelectric Quartz Crystal Mass and Dissipation Sensor: A Means of Studying Cell Adhesion
Fredriksson, C., Kihlman, S., Rodahl, M., & Kasemo, B. (1998) · Langmuir · doi:10.1021/la971005l · Cited by 242
Self-citationMuratsugu, M., Ohta, F., Miya, Y., Hosokawa, T., Kurosawa, S., Kamo, N., & Ikeda, H. (1993) · Analytical Chemistry · doi:10.1021/ac00068a036 · Cited by 233
Structural changes in protein molecules adsorbed on ultrafine silica particles
Kondo, A., Oku, S., & Higashitani, K. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90454-g · Cited by 217
Environmental applications of analytical biosensors
Marco, M. ‐., & Barceló, . (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/11/002 · Cited by 184
Interfacial phenomena and bioproducts
Brash, J. L., & Wojciechowski, P. W. (1996) · Marcel Dekker eBooks · Cited by 182
Characterization of Ferritin Adsorption onto Gold
Caruso, F., Furlong, D. N., & Kingshott, P. (1997) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1996.4625 · Cited by 176
Experimental methods for investigating protein adsorption kinetics at surfaces
Ramsden, J. J. (1994) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500002900 · Cited by 161
Horbett, T. A. (1984) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1661052 · Cited by 158
Comparison of the QCM and the SPR method for surface studies and immunological applications
Köβlinger, C., Uttenthaler, E., Drost, S., Aberl, F., Wolf, H. J., Brink, G., Stanglmaier, A., & Sackmann, E. (1995) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(95)85023-6 · Cited by 141
Kondo, A., Murakami, F., & Higashitani, K. (1992) · Biotechnology and Bioengineering · doi:10.1002/bit.260400804 · Cited by 138
Viscoelastic characterization of electroactive polymer films at the electrode/solution interface
Bandey, H. L., Hillman, A. R., Brown, M. J., & Martin, S. J. (1997) · Faraday Discussions · doi:10.1039/a704278g · Cited by 133
Cited by
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
A Survey of Structure−Property Relationships of Surfaces that Resist the Adsorption of Protein
Ostuni, E., Chapman, R. G., Holmlin, R. E., Takayama, S., & Whitesides, G. M. (2001) · Langmuir · doi:10.1021/la010384m · Cited by 1,799
Understanding protein adsorption phenomena at solid surfaces
Rabe, M., Verdes, D., & Seeger, S. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.007 · Cited by 1,664
Höök, F., Kasemo, B., Nylander, T., Fant, C., Sott, K., & Elwing, H. (2001) · Analytical Chemistry · doi:10.1021/ac0106501 · Cited by 1,162
Self-citationKasemo, B. (2002) · Surface Science · doi:10.1016/s0039-6028(01)01809-x · Cited by 1,079
Self-citation
Metadata
- Authors
- Höök, F., Rodahl, M., Kasemo, B., & Brzezinski, P.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1998-10-13
- Volume
- 95
- Issue
- 21
- Pages
- 12271-12276
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2126966136
- Cited by
- 483
- References
- 22
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.