The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Chip-based genotyping by mass spectrometry
Open accessAbstract
Silicon chips with immobilized target DNAs were used for accurate genotyping by mass spectrometry. Genomic DNAs were amplified with PCR, and the amplified products were covalently attached to chip wells via N -succinimidyl (4-iodoacetyl)aminobenzoate (SIAB) chemistry. Primer annealing, extension, and termination were performed on a 1-μl scale directly in the chip wells in parallel. Diagnostic products thus generated were detected in situ by using matrix-assisted laser desorption ionization mass spectrometry. This miniaturized method has the potential for accurate, high-throughput, low-cost identification of genetic variations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Genetic Dissection of Complex Traits
Lander, E. S., & Schork, N. J. (1994) · Science · doi:10.1126/science.8091226 · Cited by 3,413
Abundant class of human DNA polymorphisms which can be typed using the polymerase chain reaction.
Weber, J. L., & May, P. E. (1989) · Europe PMC (PubMed Central) · Cited by 3,399
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
Hypervariability of simple sequences as a general source for polymorphic DNA markers
Tautz, D. (1989) · Nucleic Acids Research · doi:10.1093/nar/17.16.6463 · Cited by 2,315
Wang, D. G., Fan, J.-B., Siao, C.-J., Berno, A., Young, P., Sapolsky, R., Ghandour, G., Perkins, N., Winchester, E., Spencer, J., et al. (1998) · Science · doi:10.1126/science.280.5366.1077 · Cited by 2,161
Litt, M., & Luty, J. A. (1989) · PubMed · Cited by 1,962
Accessing Genetic Information with High-Density DNA Arrays
Chee, M., Yang, R., Hubbell, E., Berno, A., Huang, X. C., Stern, D., Winkler, J., Lockhart, D. J., Morris, M. S., & Fodor, S. P. A. (1996) · Science · doi:10.1126/science.274.5287.610 · Cited by 1,489
DNA typing and genetic mapping with trimeric and tetrameric tandem repeats.
Edwards, A., Civitello, A. B., Hammond, H. A., & Caskey, C. T. (1991) · Europe PMC (PubMed Central) · Cited by 1,147
New Goals for the U.S. Human Genome Project: 1998-2003
Collins, F. S., Patrinos, A., Jordan, E., Chakravarti, A., Gesteland, R., Walters, L., & groups, T. M. O. T. D. A. N. P. (1998) · Science · doi:10.1126/science.282.5389.682 · Cited by 854
Infrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule Sequencing
Little, D. P., Speir, J. P., Senko, M. W., O'Connor, P. B., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a004 · Cited by 753
Kozal, M. J., Shah, N., Shen, N., Yang, R., Fucini, R., Merigan, T. C., Richman, D. D., Morris, D., Hubbell, E., Chee, M., et al. (1996) · Nature Medicine · doi:10.1038/nm0796-753 · Cited by 527
Hacia, J. G., Brody, L. C., Chee, M. S., Fodor, S. P. A., & Collins, F. S. (1996) · Nature Genetics · doi:10.1038/ng1296-441 · Cited by 516
Evaluation of 13 short tandem repeat loci for use in personal identification applications.
Hammond, H. A., Li, J., Zhong, Y., Caskey, C. T., & Chakraborty, R. (1994) · PubMed · Cited by 431
Nordhoff, E., Ingendoh, A., Cramer, R., Overberg, A., Stahl, B., Karas, M., Hillenkamp, F., Crain, P. F., & Chait, B. (1992) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290061212 · Cited by 297
An estimate of unique DNA sequence heterozygosity in the human genome
Cooper, D. N., Smith, B. A., Cooke, H. J., Niemann, S., & Schmidtke, J. (1985) · Human Genetics · doi:10.1007/bf00293024 · Cited by 293
Frégeau, C. J., & Fourney, R. M. (1993) · PubMed · Cited by 217
Fourier-transform mass spectrometry of large molecules by electrospray ionization.
Henry, K. D., Williams, E. R., Wang, B. H., McLafferty, F. W., Shabanowitz, J., & Hunt, D. F. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.23.9075 · Cited by 215
High-resolution tandem FT mass spectrometry above 10 kDa
McLafferty, F. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00047a009 · Cited by 194
Detecting CFTR gene mutations by using primer oligo base extension and mass spectrometry
Braun, A., Little, D. P., & Köster, H. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.7.1151 · Cited by 176
Self-citationSequence Information from 42−108-mer DNAs (Complete for a 50-mer) by Tandem Mass Spectrometry
Little, D. P., Aaserud, D. J., Valaskovic, G. A., & McLafferty, F. W. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9533611 · Cited by 145
Sequencing exons 5 to 8 of the p53 gene by MALDI-TOF mass spectrometry
Fu, D., Tang, K., Braun, A. D., Reuter, D., Iverson, B. L., Darnhofer-Demar, B., Little, D. P., O’Donnell, M. J., Cantor, C. R., & Köster, H. (1998) · Nature Biotechnology · doi:10.1038/nbt0498-381 · Cited by 133
Self-citationQuantitative Approach to Single-Nucleotide Polymorphism Analysis Using MALDI-TOF Mass Spectrometry
Ross, P. L., Hall, L., & Haff, L. A. (2000) · BioTechniques · doi:10.2144/00293rr05 · Cited by 106
Baseline Mass Resolution of Peptide Isobars: A Record for Molecular Mass Resolution
He, F., Hendrickson, C. L., & Marshall, A. G. (2000) · Analytical Chemistry · doi:10.1021/ac000973h · Cited by 102
Matrix-assisted laser desorption/ionization mass spectrometry of immobilized duplex DNA probes
Tang, K., Fu, D., Kötter, S., Cotter, R. J., Cantor, C. R., & Köster, H. (1995) · Nucleic Acids Research · doi:10.1093/nar/23.16.3126 · Cited by 91
Self-citationMass spectrometry from miniaturized arrays for full comparative DNA analysis
Little, D. P., Braun, A. D., O’Donnell, M. J., & Köster, H. (1997) · Nature Medicine · doi:10.1038/nm1297-1413 · Cited by 91
Self-citationButler, J. M., Li, J., Shaler, T. A., Monforte, J., & Becker, C. H. (1998) · International Journal of Legal Medicine · doi:10.1007/s004140050197 · Cited by 69
Improved Analysis of Microsatellites Using Mass Spectrometry
Braun, A. D., Little, D. P., Reuter, D., Müller-Mysok, B., & Köster, H. (1997) · Genomics · doi:10.1006/geno.1997.5011 · Cited by 62
Self-citationRoss, P. L., & Belgrader, P. (1997) · Analytical Chemistry · doi:10.1021/ac970312t · Cited by 59
Assay of the Deuterium Enrichment of Water via Acetylene
Previs, S. F., Hazey, J. W., Diraison, F., Beylot, M., David, F., & Brunengraber, H. (1996) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199606)31:6<581::aid-jms369>3.0.co;2-1 · Cited by 56
Ross, P. L., Davis, P. A., & Belgrader, P. (1998) · Analytical Chemistry · doi:10.1021/ac971256z · Cited by 46
Matrix‐assisted laser desorption/ionization of restriction enzyme‐digested DNA
Tang, K., Allman, S. L., Chen, C. H., Cháng, L. Y., & Schell, M. (1994) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290080212 · Cited by 31
Self-citationLahiri, D. K., Zhang, A., & Nürnberger, J. I. (1997) · Biochemical and Molecular Medicine · doi:10.1006/bmme.1996.2558 · Cited by 23
Cited by
The Structure of Haplotype Blocks in the Human Genome
Gabriel, S. B., Schaffner, S. F., Nguyen, H., Moore, J. M., Roy, J., Blumenstiel, B., Higgins, J., DeFelice, M., Lochner, A., Faggart, M., et al. (2002) · Science · doi:10.1126/science.1069424 · Cited by 5,863
Mutations in LRRK2 Cause Autosomal-Dominant Parkinsonism with Pleomorphic Pathology
Zimprich, A., Biskup, S., Leitner, P., Lichtner, P., Farrer, M., Lincoln, S., Kachergus, J., Hulihan, M., Uitti, R. J., Calne, D. B., et al. (2004) · Neuron · doi:10.1016/j.neuron.2004.11.005 · Cited by 3,005
Detecting recent positive selection in the human genome from haplotype structure
Sabeti, P. C., Reich, D. E., Higgins, J. M., Levine, H. Z. P., Richter, D. J., Schaffner, S. F., Gabriel, S. B., Platko, J. V., Patterson, N. J., McDonald, G. J., et al. (2002) · Nature · doi:10.1038/nature01140 · Cited by 2,106
“SNP genotyping We genotyped 49 SNPs distributed around G6PD and 37 SNPs distributed around TNFSF5 using mass spectrometry (Sequenom”
MethodClemson, C. M., Hutchinson, J. N., Sara, S. A., Ensminger, A. W., Fox, A. H., Chess, A., & Lawrence, J. B. (2009) · Molecular Cell · doi:10.1016/j.molcel.2009.01.026 · Cited by 1,445
“Detection wasby matrix-assisted laserdesorption ionization time-of-flight mass spectrometry on Sequenom (San Diego, CA) MassArray platform (Cowles et al., 2002; Tang et al., 1999).”
MethodDNA Microarray Technology: Devices, Systems, and Applications
Heller, M. J. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153438 · Cited by 1,068
Metadata
- Authors
- Tang, K., Fu, D.-J., Julien, D., Braun, A., Cantor, C. R., & Köster, H.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1999-08-31
- Volume
- 96
- Issue
- 18
- Pages
- 10016-10020
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2059297225
- Cited by
- 286
- References
- 34
- FWCI
- 14.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.