Toward the bilayer proteome, electrospray ionization-mass spectrometry of large, intact transmembrane proteins
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Genes encoding membrane proteins comprise a substantial proportion of genomes sequenced to date, but ability to perform structural studies on this portion of the proteome is limited. Electrospray ionization-MS (ESI-MS) of an intact protein generates a profile defining the native covalent state of the gene product and its heterogeneity. Here we apply ESI-MS technology with accuracy exceeding 0.01% to a hydrophobic membrane protein with 12-transmembrane α-helices, the full-length lactose permease from Escherichia coli . Furthermore, ESI-MS is used to titrate reactive thiols with N -ethylmaleimide. Treatment of the native protein solubilized in detergent micelles reveals only two reactive thiols, and both are protected by a substrate analog.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
The New Genomics: Global Views of Biology
Lander, E. S. (1996) · Science · doi:10.1126/science.274.5287.536 · Cited by 1,174
Cited by
Analysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Interaction of membrane proteins and lipids with solubilizing detergents
le Maire, M., Champeil, P., & Møller, J. V. (2000) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0304-4157(00)00010-1 · Cited by 1,029
Navab, M., Ananthramaiah, G. M., Reddy, S. T., Van Lenten, B. J., Ansell, B. J., Fonarow, G. C., Vahabzadeh, K., Hama, S., Hough, G., Kamranpour, N., et al. (2004) · Journal of Lipid Research · doi:10.1194/jlr.r400001-jlr200 · Cited by 688
Proteomics of the Chloroplast Envelope Membranes from Arabidopsis thaliana
Ferro, M., Salvi, D., Brugière, S., Miras, S., Kowalski, S., Louwagie, M., Garin, J., Joyard, J., & Rolland, N. (2003) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300030-mcp200 · Cited by 444
Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
Donnelly, D. P., Rawlins, C. M., DeHart, C. J., Fornelli, L., Schachner, L. F., Lin, Z., Lippens, J. L., Aluri, K. C., Sarin, R., Chen, B., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0457-0 · Cited by 377
Self-citation
Metadata
- Authors
- Whitelegge, J. P., le Coutre, J., Lee, J. C., Engel, C. K., Privé, G. G., Faull, K. F., & Kaback, H. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1999-09-14
- Volume
- 96
- Issue
- 19
- Pages
- 10695-10698
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1991358290
- Cited by
- 115
- References
- 2
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward the bilayer proteome, electrospray ionization-mass spectrometry of large, intact transmembrane proteins. https://app.cochat.ai/papers/10.1073/pnas.96.19.10695
- The paper
- Whitelegge, J. P., le Coutre, J., Lee, J. C., Engel, C. K., Privé, G. G., Faull, K. F., & Kaback, H. R. (1999). Toward the bilayer proteome, electrospray ionization-mass spectrometry of large, intact transmembrane proteins. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.96.19.10695
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.