Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

A cross-link breaker has sustained effects on arterial and ventricular properties in older rhesus monkeys

Open access
Vaitkevicius, Peter V., Lane, Mark, Spurgeon, Harold, Ingram, Donald K., Roth, George S., Egan, John J., Vasan, Sara, Wagle, Dilip R., Ulrich, Peter, Brines, Michael, Wuerth, Jean Paul, Cerami, Anthony, Lakatta, Edward G. · 2001 · Proceedings of the National Academy of Sciences

Abstract

Nonenzymatic glycosylation and cross-linking of proteins by glucose contributes to an age-associated increase in vascular and myocardial stiffness. Some recently sythesized thiazolium compounds selectively break these protein cross-links, reducing collagen stiffness. We investigated the effects of 3-phenacyl-4,5-dimethylthiazolium chloride (ALT-711) on arterial and left ventricular (LV) properties and their coupling in old, healthy, nondiabetic Macaca mulatta primates (age 21 ± 3.6 years). Serial measurements of arterial stiffness indices [i.e., aortic pulse wave velocity (PWV) and augmentation (AGI) of carotid arterial pressure waveform] as well as echocardiographic determinations of LV structure and function were made before and for 39 weeks after 11 intramuscular injections of ALT-711 at 1.0 mg/kg body weight every other day. Heart rate, brachial blood pressure, and body weight were unchanged by the drug. PWV and AGI decreased to a nadir at 6 weeks [PWV to 74.2 ± 4.4% of baseline (B), P = 0.007; AGI to 41 ± 7.3% of B, P = 0.046], and thereafter gradually returned to baseline. Concomitant increases in LV end diastolic diameter to 116.7 ± 2.7% of B, P = 0.02; stroke volume index (SV index ) to 173.1 ± 40.1% of B, P = 0.01; and systolic fractional shortening to 180 ± 29.7% of B, P = 0.01 occurred after drug treatment. The LV end systolic pressure/SV index , an estimate of total LV vascular load, decreased to 60 ± 12.1% of B ( P = 0.02). The LV end systolic diameter/SV index , an estimate of arterio-ventricular coupling, was improved (decreased to 54.3 ± 11% of B, P < 0.002). Thus, in healthy older primates without diabetes, ALT-711 improved both arterial and ventricular function and optimized ventriculo-vascular coupling. This previously unidentified cross-link breaker may be an effective pharmacological therapy to improve impaired cardiovascular function that occurs in the context of heart failure associated with aging, diabetes, or hypertension, conditions in which arterial and ventricular stiffness are increased.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.98.3.1171

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 262

Metadata

Authors
Vaitkevicius, P. V., Lane, M., Spurgeon, H., Ingram, D. K., Roth, G. S., Egan, J. J., Vasan, S., Wagle, D. R., Ulrich, P., Brines, M., Wuerth, J. P., Cerami, A., & Lakatta, E. G.
Venue
Proceedings of the National Academy of Sciences
Published
2001-01-30
Volume
98
Issue
3
Pages
1171-1175
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2158184576
Cited by
262
References
15
FWCI
12.70
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A cross-link breaker has sustained effects on arterial and ventricular properties in older rhesus monkeys. https://app.cochat.ai/papers/10.1073/pnas.98.3.1171
The paper
Vaitkevicius, P. V., Lane, M., Spurgeon, H., Ingram, D. K., Roth, G. S., Egan, J. J., Vasan, S., Wagle, D. R., Ulrich, P., Brines, M., Wuerth, J. P., Cerami, A., & Lakatta, E. G. (2001). A cross-link breaker has sustained effects on arterial and ventricular properties in older rhesus monkeys. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.98.3.1171

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.