Tube-Gel Digestion
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
This study describes a new protein digestion protocol in which a variety of detergents can be used to solubilize membrane proteins and facilitate trypsin digestion with higher efficiency. In this protocol, proteins are dissolved in solutions containing various detergents and directly incorporated into a polyacrylamide gel matrix without electrophoresis. Detergents are subsequently eliminated from the gel matrix while proteins are still immobilized in the gel matrix. After in-gel digestion of proteins, LC-MS/MS is used to analyze the extracted peptides for protein identification. The uniqueness of the protocol is that it allows usage of a variety of detergents in the starting solution without interfering with LC-MS/MS analysis. We hereby demonstrate that different detergents, including ionic SDS, non-ionic Triton X-100 and n-octyl beta-d-glucopyranoside, and zwitterionic CHAPS, can be used to achieve maximum solubilization of membrane proteins with minimal interference with LC-MS/MS analysis. Enhanced digestions, i.e. improved number and intensity of detected peptides, are also demonstrated for digestion-resistant proteins such as myoglobin, ubiquitin, and bacteriorhodopsin. An additional advantage of the Tube-Gel digestion protocol is that, even without electrophoresis separation, it allows high throughput analysis of complex protein mixtures when coupled with LC-MS/MS. The protocol was used to analyze a complex membrane protein mixture prepared from prostate cancer cells. The protocol involves only a single digestion and 2.5 h of LC-MS/MS analysis and identified 178 membrane proteins. In comparison, the same membrane fraction was resolved by SDS-PAGE, and 20 gel slices were excised and individually digested and analyzed by LC-MS/MS. The more elaborate effort demanded more than 50 h of LC-MS/MS analysis and identified 268 proteins. The new Tube-Gel digestion protocol is an alternative method for high throughput analysis of membrane proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Proteomics to study genes and genomes
Pandey, A., & Mann, M. (2000) · Nature · doi:10.1038/35015709 · Cited by 2,373
Fujiki, Y., Hubbard, A. L., Fowler, S., & Lazarow, P. B. (1982) · The Journal of cell biology · doi:10.1083/jcb.93.1.97 · Cited by 1,751 · cited 1×
“This isolation method can produce a highly enriched membrane fraction (8, 23, 24), including proteins that are usually difficult to solubilize and digest.”
Integrins: Emerging Paradigms of Signal Transduction
Schwartz, M. A., Schaller, M. D., & Ginsberg, M. H. (1995) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cb.11.110195.003001 · Cited by 1,594
Shevchenko, A., Jensen, O. N., Podtelejnikov, A. V., Sagliocco, F., Wilm, M., Vorm, O., Mortensen, P., Shevchenko, A., Boucherie, H., & Mann, M. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14440 · Cited by 1,427
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Evaluation of methods for the prediction of membrane spanning regions
Möller, S., Croning, M. D. R., & Apweiler, R. (2001) · Bioinformatics · doi:10.1093/bioinformatics/17.7.646 · Cited by 1,210 · cited 1×
“Of these, 96 proteins (54%) have at least one transmembrane domain as assessed by TMHMM server (prediction of transmembrane helices in proteins) (27).”
MethodTyers, M., & Mann, M. (2003) · Nature · doi:10.1038/nature01510 · Cited by 1,006
Han, D. K., Eng, J., Zhou, H., & Aebersold, R. (2001) · Nature Biotechnology · doi:10.1038/nbt1001-946 · Cited by 876
A method for the comprehensive proteomic analysis of membrane proteins
Wu, C. C., MacCoss, M. J., Howell, K. E., & Yates, J. R. (2003) · Nature Biotechnology · doi:10.1038/nbt819 · Cited by 651 · cited 1×
“This isolation method can produce a highly enriched membrane fraction (8, 23, 24), including proteins that are usually difficult to solubilize and digest.”
Cited by
Pratt, J. M., Simpson, D. M., Doherty, M. K., Rivers, J., Gaskell, S. J., & Beynon, R. J. (2006) · Nature Protocols · doi:10.1038/nprot.2006.129 · Cited by 373
Dyhrman, S. T., Jenkins, B. D., Rynearson, T. A., Saito, M. A., Mercier, M. L., Alexander, H., Whitney, L. P., Drzewianowski, A., Bulygin, V. V., Bertrand, E. M., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0033768 · Cited by 337
Membrane proteins and membrane proteomics
Tan, S., Tan, H. T., & Chung, M. C. M. (2008) · PROTEOMICS · doi:10.1002/pmic.200800597 · Cited by 279
Multiple nutrient stresses at intersecting Pacific Ocean biomes detected by protein biomarkers
Saito, M. A., McIlvin, M. R., Moran, D. M., Goepfert, T. J., DiTullio, G. R., Post, A. F., & Lamborg, C. H. (2014) · Science · doi:10.1126/science.1256450 · Cited by 215
Zhang, F., Ström, A.-L., Fukada, K., Lee, S., Hayward, L. J., & Zhu, H. (2007) · Journal of Biological Chemistry · doi:10.1074/jbc.m609743200 · Cited by 179
Self-citationRadhakrishnan, A., Yeo, D., Brown, G., Myaing, M. Z., Iyer, L. R., Fleck, R., Tan, B.-H., Aitken, J., Sanmun, D., Tang, K., et al. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.001651 · Cited by 114
Doucette, A. A., Vieira, D. B., Orton, D. J., & Wall, M. J. (2014) · Journal of Proteome Research · doi:10.1021/pr500864a · Cited by 63
Proteomic analysis of the microenvironment of developing oocytes
Twigt, J., Steegers‐Theunissen, R. P., Bezstarosti, K., & Demmers, J. A. A. (2012) · PROTEOMICS · doi:10.1002/pmic.201100240 · Cited by 58
Co-occurrence of Fe and P stress in natural populations of the marine diazotroph Trichodesmium
Held, N. A., Webb, E. A., McIlvin, M. M., Hutchins, D. A., Cohen, N. R., Moran, D. M., Kunde, K., Lohan, M. C., Mahaffey, C., Woodward, E. M. S., et al. (2020) · Biogeosciences · doi:10.5194/bg-17-2537-2020 · Cited by 45
The benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Lin, Y., Lin, H., Liu, Z., Wang, K., & Yan, Y. (2014) · Journal of Separation Science · doi:10.1002/jssc.201400569 · Cited by 23
Lin, Y., Wang, K., Liu, Z., Lin, H., & Yu, L. (2015) · Journal of Chromatography B · doi:10.1016/j.jchromb.2015.08.019 · Cited by 14
Metadata
- Authors
- Lu, X., & Zhu, H.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2005-12
- Volume
- 4
- Issue
- 12
- Pages
- 1948-1958
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2134852489
- Cited by
- 191
- References
- 26
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.