Advances and Challenges in Liquid Chromatography-Mass Spectrometry-based Proteomics Profiling for Clinical Applications
Open accessThe DOI matches its Crossref record; 108 of the 108 references it cites were found in a registry or an index.
Abstract
Recent advances in proteomics technologies provide tremendous opportunities for biomarker-related clinical applications; however, the distinctive characteristics of human biofluids such as the high dynamic range in protein abundances and extreme complexity of the proteomes present tremendous challenges. In this review we summarize recent advances in LC-MS-based proteomics profiling and its applications in clinical proteomics as well as discuss the major challenges associated with implementing these technologies for more effective candidate biomarker discovery. Developments in immunoaffinity depletion and various fractionation approaches in combination with substantial improvements in LC-MS platforms have enabled the plasma proteome to be profiled with considerably greater dynamic range of coverage, allowing many proteins at low ng/ml levels to be confidently identified. Despite these significant advances and efforts, major challenges associated with the dynamic range of measurements and extent of proteome coverage, confidence of peptide/protein identifications, quantitation accuracy, analysis throughput, and the robustness of present instrumentation must be addressed before a proteomics profiling platform suitable for efficient clinical applications can be routinely implemented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Keller, A., Nesvizhskii, A. I., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,830
A Statistical Model for Identifying Proteins by Tandem Mass Spectrometry
Nesvizhskii, A. I., Keller, A., Kolker, E., & Aebersold, R. (2003) · Analytical Chemistry · doi:10.1021/ac0341261 · Cited by 4,809
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,752
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
TANDEM: matching proteins with tandem mass spectra
Craig, R., & Beavis, R. C. (2004) · Bioinformatics · doi:10.1093/bioinformatics/bth092 · Cited by 2,536
A Model for Random Sampling and Estimation of Relative Protein Abundance in Shotgun Proteomics
Liu, H., Sadygov, R. G., & Yates, J. R. (2004) · Analytical Chemistry · doi:10.1021/ac0498563 · Cited by 2,500
Cited by
Analysis and validation of proteomic data generated by tandem mass spectrometry
Nesvizhskii, A. I., Vitek, O., & Aebersold, R. (2007) · Nature Methods · doi:10.1038/nmeth1088 · Cited by 629
An Integrated Clinico-Metabolomic Model Improves Prediction of Death in Sepsis
Langley, R. J., Tsalik, E. L., Velkinburgh, J. C. V., Glickman, S. W., Rice, B. J., Wang, C., Chen, B., Carin, L., Suarez, A., Mohney, R. P., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005893 · Cited by 507
Decramer, S., de Peredo, A. G., Breuil, B., Mischak, H., Monsarrat, B., Bascands, J.-L., & Schanstra, J. P. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r800001-mcp200 · Cited by 450
Zhang, Q., Ames, J. M., Smith, R. D., Baynes, J. W., & Metz, T. O. (2009) · Journal of Proteome Research · doi:10.1021/pr800858h · Cited by 421
Self-citationEffect of eluent on the ionization process in liquid chromatography–mass spectrometry
Kostiainen, R., & Kauppila, T. J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.095 · Cited by 402
Significance Analysis of Spectral Count Data in Label-free Shotgun Proteomics
Choi, H., Fermin, D., & Nesvizhskii, A. I. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800203-mcp200 · Cited by 364
“Despite the rich information contained in the LC-MS data, daunting computational effort needs to be spent on processing the data, including background filtering, peak detection, and alignment (8, 11).”
BackgroundMethodHigh-sensitivity Analytical Approaches for the Structural Characterization of Glycoproteins
Alley, W. R., Mann, B. F., & Novotny, M. V. (2013) · Chemical Reviews · doi:10.1021/cr3003714 · Cited by 310
Obermeier, B., Mentele, R., Malotka, J., Kellermann, J., Kümpfel, T., Wekerle, H., Lottspeich, F., Hohlfeld, R., & Dornmair, K. (2008) · Nature Medicine · doi:10.1038/nm1714 · Cited by 292
Ionization and transmission efficiency in an electrospray ionization—mass spectrometry interface
Page, J. S., Kelly, R. T., Tang, K., & Smith, R. D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.05.018 · Cited by 265
Self-citationAdvancing the sensitivity of selected reaction monitoring‐based targeted quantitative proteomics
Shi, T., Su, D., Liu, T., Tang, K., Camp, D. G., Qian, W., & Smith, R. D. (2012) · PROTEOMICS · doi:10.1002/pmic.201100436 · Cited by 245
“Without immunoaffinity depletion and prefractionation, LC-SRM-based assays are generally only able to quantify moderate-abundance proteins in the low g/mL concentration range using conventional platforms [32, 40], and potentially able to detect proteins in the 10–100 ng/mL concentration range when applying the dual io…”
BackgroundMethodSelf-citationRay, S., Reddy, P. J., Jain, R., Gollapalli, K., Moiyadi, A., & Srivastava, S. (2011) · PROTEOMICS · doi:10.1002/pmic.201000460 · Cited by 224
“Limited dynamic range, low-throughput and issues of robustness and cost are the major challenges and limitations of current LC-MS-based proteomics technologies applied to biomarker discovery [82].”
BackgroundLiquid Chromatography-Mass Spectrometry-based Quantitative Proteomics
Xie, F., Liu, T., Qian, W.-J., Petyuk, V. A., & Smith, R. D. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.r110.199703 · Cited by 215
Self-citationQian, W.-J., Kaleta, D. T., Petritis, B. O., Jiang, H., Liu, T., Zhang, X., Mottaz, H. M., Varnum, S. M., Camp, D. G., Huang, L., et al. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800008-mcp200 · Cited by 208
“at concentrations of ng/ml or lower remains a challenge ( 4 ).”
BackgroundResultInfluentialSelf-citationThe cancer cell secretome: A good source for discovering biomarkers?
Pavlou, M. P., & Diamandis, E. P. (2010) · Journal of Proteomics · doi:10.1016/j.jprot.2010.04.003 · Cited by 200
Zhang, J., Guy, M. J., Norman, H. S., Chen, Y.-C., Xu, Q., Dong, X., Guner, H., Wang, S., Kohmoto, T., Young, K. H., et al. (2011) · Journal of Proteome Research · doi:10.1021/pr200258m · Cited by 194
Kalli, A., Smith, G. T., Sweredoski, M. J., & Hess, S. (2013) · Journal of Proteome Research · doi:10.1021/pr3011588 · Cited by 166
Contribution of Protein Fractionation to Depth of Analysis of the Serum and Plasma Proteomes
Faca, V., Pitteri, S. J., Newcomb, L., Glukhova, V., Phanstiel, D., Krasnoselsky, A., Zhang, Q., Struthers, J., Wang, H., Eng, J., et al. (2007) · Journal of Proteome Research · doi:10.1021/pr070233q · Cited by 164
Novel MMP-9 Substrates in Cancer Cells Revealed by a Label-free Quantitative Proteomics Approach
Xu, D., Suenaga, N., Edelmann, M. J., Fridman, R., Muschel, R. J., & Kessler, B. M. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800095-mcp200 · Cited by 162
“This method has been problematic for proteomics analysis because of the low reproducibility of nano-LC runs and the requirement for MS to MS/MS switching to obtain sequence information, resulting in low quality chromatograms ( 32 ).”
BackgroundMethodInfluentialZhang, Q., Tang, N., Brock, J. W. C., Mottaz, H. M., Ames, J. M., Baynes, J. W., Smith, R. D., & Metz, T. O. (2007) · Journal of Proteome Research · doi:10.1021/pr070112q · Cited by 161
Self-citationClinical microfluidics for neutrophil genomics and proteomics
Program, T. I. A. T. H. R. T. I. C. R., Kotz, K. T., Xiao, W., Miller-Graziano, C., Qian, W.-J., Russom, A., Warner, E. A., Moldawer, L. L., De, A., Bankey, P. E., et al. (2010) · Nature Medicine · doi:10.1038/nm.2205 · Cited by 161
“Peptides were identified on the basis of the accurate mass and time tag strategy against a neutrophil accurate mass and time tag database preestablished by extensive LC–tandem MS profilin”
MethodSelf-citationDiamond, D. L., Jacobs, J. M., Paeper, B., Proll, S. C., Gritsenko, M. A., Carithers, R. L., Larson, A. M., Yeh, M. M., Camp, D. G., Smith, R. D., et al. (2007) · Hepatology · doi:10.1002/hep.21751 · Cited by 114
Self-citationWu, Q., Yuan, H., Zhang, L., & Zhang, Y. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.04.010 · Cited by 94
The continuing evolution of cardiac troponin I biomarker analysis: from protein to proteoform
Soetkamp, D., Raedschelders, K., Mastali, M., Sobhani, K., Bairey Merz, C. N., & Van Eyk, J. (2017) · Expert Review of Proteomics · doi:10.1080/14789450.2017.1387054 · Cited by 36
“(2) The broad dynamic range in plasma and serum protein concentrations [140].”
Metadata
- Authors
- Qian, W.-J., Jacobs, J. M., Liu, T., Camp, D. G., & Smith, R. D.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2006-10
- Volume
- 5
- Issue
- 10
- Pages
- 1727-1744
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2121863513
- Cited by
- 362
- References
- 108
- FWCI
- 15.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.