Experimental and Statistical Considerations to Avoid False Conclusions in Proteomics Studies Using Differential In-gel Electrophoresis
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
In quantitative proteomics, the false discovery rate (FDR) can be defined as the number of false positives within statistically significant changes in expression. False positives accumulate during the simultaneous testing of expression changes across hundreds or thousands of protein or peptide species when univariate tests such as the Student's t test are used. Currently most researchers rely solely on the estimation of p values and a significance threshold, but this approach may result in false positives because it does not account for the multiple testing effect. For each species, a measure of significance in terms of the FDR can be calculated, producing individual q values. The q value maintains power by allowing the investigator to achieve an acceptable level of true or false positives within the calls of significance. The q value approach relies on the use of the correct statistical test for the experimental design. In this situation, a uniform p value frequency distribution when there are no differences in expression between two samples should be obtained. Here we report a bias in p value distribution in the case of a three-dye DIGE experiment where no changes in expression are occurring. The bias was shown to arise from correlation in the data from the use of a common internal standard. With a two-dye schema, where each sample has its own internal standard, such bias was removed, enabling the application of the q value to two different proteomics studies. In the case of the first study, we demonstrate that 80% of calls of significance by the more traditional method are false positives. In the second, we show that calculating the q value gives the user control over the FDR. These studies demonstrate the power and ease of use of the q value in correcting for multiple testing. This work also highlights the need for robust experimental design that includes the appropriate application of statistical procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482 · cited 1×
“Benjamini and Hochberg (15) originally defined the false discovery rate as a proportion of changes identified as significant that are false.”
BackgroundStatistical significance for genomewide studies
Storey, J. D., & Tibshirani, R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1530509100 · Cited by 9,692 · cited 7×
“An extension to the FDR was developed by Storey and calculates a q value for each tested feature (16, 17).”
BackgroundMethodInfluentialCasella, G., & Berger, R. (2024) · Chapman & Hall/CRC eBooks · doi:10.1201/9781003456285 · Cited by 5,711
A Direct Approach to False Discovery Rates
Storey, J. D. (2002) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00346 · Cited by 5,603 · cited 2×
“An extension to the FDR was developed by Storey and calculates a q value for each tested feature (16, 17).”
MethodMultiple significance tests: the Bonferroni method
Bland, J. M., & Altman, D. G. (1995) · BMJ · doi:10.1136/bmj.310.6973.170 · Cited by 3,341
Comparison of Label-free Methods for Quantifying Human Proteins by Shotgun Proteomics
Old, W. M., Meyer-Arendt, K., Aveline-Wolf, L., Pierce, K. G., Mendoza, A., Sevinsky, J. R., Resing, K. A., & Ahn, N. G. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500084-mcp200 · Cited by 1,206
Some Practical Guidelines for Effective Sample Size Determination
Lenth, R. V. (2001) · The American Statistician · doi:10.1198/000313001317098149 · Cited by 1,139 · cited 2×
“Completing a power study using the Lenth (31) power tool clearly demonstrates that with only four replicates the power in detecting change was low due to the high biological noise (Fig.”
MethodStatistical tests for differential expression in cDNA microarray experiments
Cui, X., & Churchill, G. A. (2003) · Genome Biology · doi:10.1186/gb-2003-4-4-210 · Cited by 896
The development of the DIGE system: 2D fluorescence difference gel analysis technology
Marouga, R., David, S., & Hawkins, E. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3126-3 · Cited by 636 · cited 1×
“Typically the Cy3 and Cy5 CyDyes are used to label two samples from two independent groups to ensure a dye and gel balance (7, 26).”
MethodStatistical Issues in cDNA Microarray Data Analysis
Smyth, G. K., Yang, Y. H., & Speed, T. (2003) · Functional Genomics · doi:10.1385/1-59259-364-x:111 · Cited by 466
Cited by
Difference gel electrophoresis
Timms, J. F., & Cramer, R. (2008) · PROTEOMICS · doi:10.1002/pmic.200800298 · Cited by 267
Two-dimensional gel electrophoresis in proteomics: A tutorial
Rabilloud, T., & Lelong, C. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.05.040 · Cited by 258
Statistical Design of Quantitative Mass Spectrometry-Based Proteomic Experiments
Oberg, A. L., & Vitek, O. (2009) · Journal of Proteome Research · doi:10.1021/pr8010099 · Cited by 256
Jorrín-Novo, J. V., Maldonado, A. M., Echevarría-Zomeño, S., Valledor, L., Castillejo, M. A., Curto, M., Valero, J., Sghaier, B., Donoso, G., & Redondo, I. (2009) · Journal of Proteomics · doi:10.1016/j.jprot.2009.01.026 · Cited by 220
Comparative LC‐MS: A landscape of peaks and valleys
America, A. H. P., & Cordewener, J. H. G. (2008) · PROTEOMICS · doi:10.1002/pmic.200700694 · Cited by 191
“To correct for this, statistical methods have been developed to control this False-DicoveryRate [18, 113–115].”
BackgroundMethodProteomics technologies for the global identification and quantification of proteins
Brewis, I. A., & Brennan, P. (2010) · Advances in Protein Chemistry and Structural Biology · doi:10.1016/b978-0-12-381264-3.00001-1 · Cited by 171
Valledor, L., & Jorrín, J. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2010.07.007 · Cited by 168
Deery, M. J., Maywood, E. S., Chesham, J. E., Sládek, M., Karp, N. A., Green, E. W., Charles, P. D., Reddy, A. B., Kyriacou, C. P., Lilley, K. S., et al. (2009) · Current Biology · doi:10.1016/j.cub.2009.10.024 · Cited by 125
“aliquots were minimally labelled with 200 pmol Cy3 and Cy5 reagents (GE Healthcare), respectively, for 15 min at 4oC in the dark, according to the method of Karp and Lilley [1].”
InfluentialSelf-citationWasinger, V. C., Curnoe, D., Bustamante, S., Mendoza, R., Shoocongdej, R., Adler, L., Baker, A., Chintakanon, K., Boel, C., & Tacon, P. S. C. (2019) · PROTEOMICS · doi:10.1002/pmic.201800341 · Cited by 43
Metadata
- Authors
- Karp, N. A., McCormick, P. S., Russell, M. R., & Lilley, K. S.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2007-08
- Volume
- 6
- Issue
- 8
- Pages
- 1354-1364
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2107580534
- Cited by
- 165
- References
- 29
- FWCI
- 8.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.