Parts per Million Mass Accuracy on an Orbitrap Mass Spectrometer via Lock Mass Injection into a C-trap
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Mass accuracy is a key parameter of mass spectrometric performance. TOF instruments can reach low parts per million, and FT-ICR instruments are capable of even greater accuracy provided ion numbers are well controlled. Here we demonstrate sub-ppm mass accuracy on a linear ion trap coupled via a radio frequency-only storage trap (C-trap) to the orbitrap mass spectrometer (LTQ Orbitrap). Prior to acquisition of a spectrum, a background ion originating from ambient air is first transferred to the C-trap. Ions forming the MS or MS(n) spectrum are then added to this species, and all ions are injected into the orbitrap for analysis. Real time recalibration on the "lock mass" by corrections of mass shift removes mass error associated with calibration of the mass scale. The remaining mass error is mainly due to imperfect peaks caused by weak signals and is addressed by averaging the mass measurement over the LC peak, weighted by signal intensity. For peptide database searches in proteomics, we introduce a variable mass tolerance and achieve average absolute mass deviations of 0.48 ppm (standard deviation 0.38 ppm) and maximal deviations of less than 2 ppm. For tandem mass spectra we demonstrate similarly high mass accuracy and discuss its impact on database searching. High and routine mass accuracy in a compact instrument will dramatically improve certainty of peptide and small molecule identification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955 · cited 1×
“In a typical proteomics experiment, protein mixtures are digested to peptide mixtures that are separated by reversed phase HPLC and analyzed on-line by MS and MS/MS ( 6 ).”
MethodSelf-citationOng, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574 · cited 6×
“SILAC Labeling of Yeast-K_out-strain—”
MethodSelf-citationKeller, A., Nesvizhskii, A. I., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,830
Rappsilber, J., Ishihama, Y., & Mann, M. (2003) · Analytical Chemistry · doi:10.1021/ac026117i · Cited by 2,644
Self-citationError-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence Tags
Mann, M., & Wilm, M. (1994) · Analytical Chemistry · doi:10.1021/ac00096a002 · Cited by 1,468
Self-citationThe Orbitrap: a new mass spectrometer
Hu, Q., Noll, R. J., Li, H., Makarov, A., Hardman, M., & Graham Cooks, R. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.856 · Cited by 1,333
Self-citationTrypsin Cleaves Exclusively C-terminal to Arginine and Lysine Residues
Olsen, J. V., Ong, S.-E., & Mann, M. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t400003-mcp200 · Cited by 1,254
Self-citationThe abc's (and xyz's) of peptide sequencing
Steen, H., & Mann, M. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1468 · Cited by 1,150
Self-citationAndersen, J. S., Lam, Y. W., Leung, A. K. L., Ong, S.-E., Lyon, C. E., Lamond, A. I., & Mann, M. (2005) · Nature · doi:10.1038/nature03207 · Cited by 1,149
Self-citationClauser, K. R., Baker, P., & Burlingame, A. L. (1999) · Analytical Chemistry · doi:10.1021/ac9810516 · Cited by 1,093
Electrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009
Self-citationUnbiased quantitative proteomics of lipid rafts reveals high specificity for signaling factors
Foster, L. J., de Hoog, C. L., & Mann, M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0631608100 · Cited by 834
Self-citationA two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Quantitative Phosphoproteomics Applied to the Yeast Pheromone Signaling Pathway
Gruhler, A., Olsen, J. V., Mohammed, S., Mortensen, P., Færgeman, N. J., Mann, M., & Jensen, O. N. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400219-mcp200 · Cited by 763
Self-citationAnalysis of the Plasmodium falciparum proteome by high-accuracy mass spectrometry
Lasonder, E., Ishihama, Y., Andersen, J. S., Vermunt, A. M. W., Pain, A., Sauerwein, R. W., Eling, W. M. C., Hall, N., Waters, A. P., Stunnenberg, H. G., et al. (2002) · Nature · doi:10.1038/nature01111 · Cited by 652
Self-citationIdentifying and quantifying in vivo methylation sites by heavy methyl SILAC
Ong, S.-E., Mittler, G., & Mann, M. (2004) · Nature Methods · doi:10.1038/nmeth715 · Cited by 456
Self-citationKingdon, K. H. (1923) · Physical Review · doi:10.1103/physrev.21.408 · Cited by 390
Syka, J. E. P., Marto, J. A., Bai, D. L., Horning, S., Senko, M. W., Schwartz, J. C., Ueberheide, B., Garcia, B., Busby, S., Muratore, T., et al. (2004) · Journal of Proteome Research · doi:10.1021/pr0499794 · Cited by 348
Self-citationInterfacing the Orbitrap Mass Analyzer to an Electrospray Ion Source
Hardman, M., & Makarov, A. A. (2003) · Analytical Chemistry · doi:10.1021/ac0258047 · Cited by 314
Self-citationOlsen, J. V., & Mann, M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405549101 · Cited by 313
Self-citationJensen, O. N., Podtelejnikov, A., & Mann, M. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199608)10:11<1371::aid-rcm682>3.0.co;2-5 · Cited by 297
Self-citationRoutine Part-per-Million Mass Accuracy for High- Mass Ions: Space-Charge Effects in MALDI FT-ICR
Easterling, M. L., Mize, T. H., & Amster, I. J. (1998) · Analytical Chemistry · doi:10.1021/ac980690d · Cited by 150
Nielsen, M. L., Savitski, M. M., & Zubarev, R. A. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t400022-mcp200 · Cited by 139
Spengler, B. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.01.007 · Cited by 138
Accuracy Requirements for Peptide Characterization by Monoisotopic Molecular Mass Measurements
Zubarev, R. A., Håkansson, P., & Sundqvist, B. (1996) · Analytical Chemistry · doi:10.1021/ac9604651 · Cited by 126
Spengler, B. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(04)00073-x · Cited by 124
Savitski, M. M., Nielsen, M. L., & Zubarev, R. A. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500009-mcp200 · Cited by 102
Belov, M. E., Zhang, R., Strittmatter, E. F., Prior, D. C., Tang, K., & Smith, R. D. (2003) · Analytical Chemistry · doi:10.1021/ac0206770 · Cited by 89
Chen, L., Cottrell, C. E., & Marshall, A. G. (1986) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(86)80025-9 · Cited by 80
Internal Calibration on Adjacent Samples (InCAS) with Fourier Transform Mass Spectrometry
O’Connor, P. B., & Costello, C. E. (2000) · Analytical Chemistry · doi:10.1021/ac000770t · Cited by 69
Adkins, J., Monroe, M. E., Auberry, K. J., Shen, Y., Jacobs, J., Camp, D., Vitzthum, F., Rodland, K., Zangar, R. C., Smith, R. D., et al. (2005) · PROTEOMICS · doi:10.1002/pmic.200401333 · Cited by 61
Mayya, V., Rezaul, K., Cong, Y., & Han, D. K. M. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t400015-mcp200 · Cited by 56
Peptide End Sequencing by Orthogonal MALDI Tandem Mass Spectrometry
Nielsen, M. L., Bennett, K. L., Larsen, B. G., et al. (2002) · Journal of Proteome Research · doi:10.1021/pr0155174 · Cited by 34
Cited by
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Self-citationUniversal sample preparation method for proteome analysis
Wiśniewski, J. R., Zougman, A., Nagaraj, N., & Mann, M. (2009) · Nature Methods · doi:10.1038/nmeth.1322 · Cited by 8,352
Self-citationCox, J., Hein, M. Y., Luber, C. A., Paron, I., Nagaraj, N., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031591 · Cited by 5,180
“Each fraction was purified with C18 StageTips (46) and analyzed via liquid chromatography combined with electrospray tandem mass spectrometry on an LTQ Orbitrap (Thermo Fisher) with lock mass calibration (47).”
MethodSelf-citationLysine acetylation targets protein complexes and co-regulates major cellular functions
Choudhary, C., Kumar, C., Gnad, F., Nielsen, M. L., Rehman, M., Walther, T. C., Olsen, J. V., & Mann, M. (2009) · Science · doi:10.1126/science.1175371 · Cited by 4,040
Self-citationGlobal, In Vivo, and Site-Specific Phosphorylation Dynamics in Signaling Networks
Olsen, J. V., Blagoev, B., Gnad, F., Macek, B., Kumar, C., Mortensen, P., & Mann, M. (2006) · Cell · doi:10.1016/j.cell.2006.09.026 · Cited by 3,499
Self-citation
Metadata
- Authors
- Olsen, J. V., de Godoy, L. M. F., Li, G., Macek, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S., & Mann, M.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2005-12
- Volume
- 4
- Issue
- 12
- Pages
- 2010-2021
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2134749398
- Cited by
- 1,510
- References
- 34
- FWCI
- 22.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.