Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant

Gantz, Bruce J., Turner, Christopher · 2004 · Acta Oto-Laryngologica
Cited by 204

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: In this paper we test the concept of combining electrical stimulation for high-frequency sound with acoustic hearing for low-frequency information in the same ear. In addition, we test whether residual hearing can be preserved when an electrode is placed up to 10 mm into the inner ear, and whether the site of electrical stimulation influences speech perception. MATERIAL AND METHODS: Nine post-lingual adults with severe high-frequency hearing impairment were recruited to participate in the study. A single-subject clinical trial design was employed. A unique six-channel cochlear implant was designed for this clinical trial. The intracochlear electrodes were either 6 or 10 mm in length based on a Nucleus CI-24 multichannel implant. Monosyllabic word understanding and consonant identification in a recorded sound-only condition were used to assess changes in speech perception. Follow-up was > 12 months. RESULTS: Acoustic hearing was preserved in all nine subjects. Preoperative monosyllabic word and sentence scores were unchanged in all subjects following implantation. A 30-40% improvement in consonant recognition occurred with the 10-mm electrode. The 10-mm electrode subjects were able to understand 83-90% of the monosyllabic words using the implant plus binaural hearing aids. Scores were more than doubled when compared to preoperative scores achieved with hearing aids only. CONCLUSIONS: The human ear has the capability to integrate both acoustic and high-frequency electrically processed speech information. Placement of a short 10-mm electrode does not appear to damage residual low-frequency inner ear hair cell function, interfere with the micro-mechanics of normal cochlear vibration or decrease residual speech perception. The improvement in speech recognition was due primarily to the increased perception of higher-frequency consonantal speech cues. Such a device can provide a substantial benefit in terms of speech understanding to those with severe high-frequency hearing loss, while still maintaining the benefits of the residual lower-frequency acoustic hearing. The position of the electrode and the site of frequency information within the cochlea are shown to be important factors in the success of such a device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00016480410016423

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 204

Metadata

Authors
Gantz, B. J., & Turner, C.
Venue
Acta Oto-Laryngologica
Published
2004-05-01
Volume
124
Issue
4
Pages
344-347
ISSN
  • 0001-6489 (ISSN-L)
  • 1651-2251
OpenAlex
W2162149778
Cited by
204
References
11
FWCI
5.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant. https://app.cochat.ai/papers/10.1080/00016480410016423
The paper
Gantz, B. J., & Turner, C. (2004). Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant. Acta Oto-Laryngologica. https://doi.org/10.1080/00016480410016423

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.