Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: In this paper we test the concept of combining electrical stimulation for high-frequency sound with acoustic hearing for low-frequency information in the same ear. In addition, we test whether residual hearing can be preserved when an electrode is placed up to 10 mm into the inner ear, and whether the site of electrical stimulation influences speech perception. MATERIAL AND METHODS: Nine post-lingual adults with severe high-frequency hearing impairment were recruited to participate in the study. A single-subject clinical trial design was employed. A unique six-channel cochlear implant was designed for this clinical trial. The intracochlear electrodes were either 6 or 10 mm in length based on a Nucleus CI-24 multichannel implant. Monosyllabic word understanding and consonant identification in a recorded sound-only condition were used to assess changes in speech perception. Follow-up was > 12 months. RESULTS: Acoustic hearing was preserved in all nine subjects. Preoperative monosyllabic word and sentence scores were unchanged in all subjects following implantation. A 30-40% improvement in consonant recognition occurred with the 10-mm electrode. The 10-mm electrode subjects were able to understand 83-90% of the monosyllabic words using the implant plus binaural hearing aids. Scores were more than doubled when compared to preoperative scores achieved with hearing aids only. CONCLUSIONS: The human ear has the capability to integrate both acoustic and high-frequency electrically processed speech information. Placement of a short 10-mm electrode does not appear to damage residual low-frequency inner ear hair cell function, interfere with the micro-mechanics of normal cochlear vibration or decrease residual speech perception. The improvement in speech recognition was due primarily to the increased perception of higher-frequency consonantal speech cues. Such a device can provide a substantial benefit in terms of speech understanding to those with severe high-frequency hearing loss, while still maintaining the benefits of the residual lower-frequency acoustic hearing. The position of the electrode and the site of frequency information within the cochlea are shown to be important factors in the success of such a device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control Methods Used in a Study of the Vowels
Peterson, G. E., & Barney, H. L. (1952) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906875 · Cited by 2,837 · cited 1×
“One important unifying factor in the perception of speech is that the ratios of the spectral peaks (formants) are relatively constant across various talkers for each given speech sound (11).”
BackgroundLanguage Development in Profoundly Deaf Children with Cochlear Implants
Svirsky, M. A., Robbins, A. M., Kirk, K. I., Pisoni, D. B., & Miyamoto, R. T. (2000) · Psychological Science · doi:10.1111/1467-9280.00231 · Cited by 647
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Self-citationHigh-frequency audibility: Benefits for hearing-impaired listeners
Hogan, C. A., & Turner, C. W. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423247 · Cited by 360
Self-citationTomblin, J. B., Spencer, L., Flock, S., Tyler, R., & Gantz, B. (1999) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4202.497 · Cited by 254
Self-citationXu, J., Shepherd, R. K., Millard, R. E., & Clark, G. M. (1997) · Hearing Research · doi:10.1016/s0378-5955(96)00193-1 · Cited by 242
Leake, P. A., Hradek, G. T., Rebscher, S. J., & Snyder, R. L. (1991) · Hearing Research · doi:10.1016/0378-5955(91)90120-x · Cited by 206 · cited 1×
“Maintaining residual hair cell function, as accomplished with the short electrode, is also important for the long-term preservation of auditory spiral ganglion nerve populations (14, 15).”
BackgroundSpeech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.417043 · Cited by 169
Ni, D.-F., Shepherd, R. K., Seldon, H. L., Xu, S.-A., Clark, G. M., & Millard, R. E. (1992) · Hearing Research · doi:10.1016/0378-5955(92)90203-y · Cited by 104 · cited 1×
“Previous research in hearing animals suggests that electrodes of limited length can be implanted while preserving auditory function (9, 10).”
BackgroundAraki, S., Kawano, A., Seldon, H. L., Shepherd, R. K., Funasaka, S., & Clark, G. M. (1998) · The Laryngoscope · doi:10.1097/00005537-199805000-00012 · Cited by 62 · cited 1×
“Maintaining residual hair cell function, as accomplished with the short electrode, is also important for the long-term preservation of auditory spiral ganglion nerve populations (14, 15).”
Background
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Self-citationPresbycusis: An Update on Cochlear Mechanisms and Therapies
Wang, J., & Puel, J.-L. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9010218 · Cited by 234
“Efforts to ensure the preservation of residual hearing rely on the use of soft-surgery techniques and the implantation of shorter electrode arrays to minimize the trauma caused during the process of electrode insertion [133,134].”
BackgroundZhang, T., Dorman, M. F., & Spahr, A. J. (2010) · Ear & Hearing · doi:10.1097/aud.0b013e3181b7190c · Cited by 177
“…acoustic hearing in the implanted ear or in the nonimplanted ear (Shallop et al. 1992; Armstrong et al. 1997; Tyler et al. 2002; Ching et al. 2004; Gantz & Turner 2004; Gstoettner et al. 2004; Kiefer et al. 2004; Turner et al. 2004; Kong et al. 2005; Mok et al. 2006; Gifford et al. 2007; Dorman…”
BackgroundGantz, B. J., Turner, C., & Gfeller, K. E. (2006) · Audiology and Neurotology · doi:10.1159/000095616 · Cited by 170
“Results with this electrode demonstrate that pure tone thresholds can be preserved as well as residual acoustic word discrimination [Gantz and Turner, 2004].”
BackgroundSelf-citation
Metadata
- Authors
- Gantz, B. J., & Turner, C.
- Venue
- Acta Oto-Laryngologica
- Publisher
- Informa UK Limited
- Published
- 2004-05-01
- Volume
- 124
- Issue
- 4
- Pages
- 344-347
- ISSN
- 0001-6489 (ISSN-L)
- 1651-2251
- OpenAlex
- W2162149778
- Cited by
- 204
- References
- 11
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant. https://app.cochat.ai/papers/10.1080/00016480410016423
- The paper
- Gantz, B. J., & Turner, C. (2004). Combining acoustic and electrical speech processing: Iowa/Nucleus hybrid implant. Acta Oto-Laryngologica. https://doi.org/10.1080/00016480410016423
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.