Chronic Electrical Stimulation of the Auditory Nerve using Non-charge-balanced Stimuli
The DOI matches its Crossref record.
Abstract
This study was designed to evaluate the pathophysiological response of the cochlea following long-term intracochlear electrical stimulation using a poorly charge-balanced stimulus regime, leading to direct current (DC) levels >0.1 microA. Four normal-hearing adult cats were bilaterally implanted with scala tympani electrode arrays and unilaterally stimulated for periods up to 2200 h. Stimuli consisted of 50 micros monophasic current pulses presented at 2000 pulses per second (pps) per channel, and resulted in DC levels of 0.4-2.8 microA. Both acoustic and electrical (EABR) evoked potentials were periodically recorded during the stimulation program. Frequency-specific stimuli indicated that an extensive and widespread hearing loss occurred over the 4-24 KHz region in all stimulated cochleae, although the 2 KHz region exhibited thresholds close to normal in some animals, despite long-term implantation and chronic stimulation. Longitudinal EABRs showed a statistically significant increase in threshold for three of the four animals. Histopathological evaluation of the cochleae revealed a highly significant reduction in ganglion cell density in stimulated cochleae compared with their controls. Spiral ganglion cell loss was significantly correlated with the degree of inflammation, duration of electrical stimulation, and the level of DC. In conclusion, the present study highlights the potential for neural damage following stimulation using poorly charge-balanced stimuli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
An integrative model of tinnitus based on a central gain controlling neural sensitivity
Noreña, A. J. (2011) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2010.11.003 · Cited by 452
Sit, J.-J., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.911631 · Cited by 155
“highly correlated with neural tissue damage [ 2 ], and since stimulation currents may need to be as high as 1 mA, a dc error of 0.01% is required.”
BackgroundInfluentialA Fully Intraocular High-Density Self-Calibrating Epiretinal Prosthesis
Monge, M., Raj, M., Nazari, M. H., Chang, H.-C., Zhao, Y., Weiland, J. D., Humayun, M. S., Tai, Y.-C., & Emami, A. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298334 · Cited by 85
Butz, N., Taschwer, A., Nessler, S., Manoli, Y., & Kuhl, M. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2828823 · Cited by 70
“Maximum allowed net currents are defined in [20], being determined by observing tissue”
BackgroundMurphy, B., Krieger, C., & Hoffer, J.-A. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.08.013 · Cited by 13
Metadata
- Authors
- Shepherd, R. K.
- Venue
- Acta Oto-Laryngologica
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 119
- Issue
- 6
- Pages
- 674-684
- ISSN
- 0001-6489 (ISSN-L)
- 1651-2251
- OpenAlex
- W1971494066
- Cited by
- 81
- References
- 0
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronic Electrical Stimulation of the Auditory Nerve using Non-charge-balanced Stimuli. https://app.cochat.ai/papers/10.1080/00016489950180621
- The paper
- Shepherd, R. K. (1999). Chronic Electrical Stimulation of the Auditory Nerve using Non-charge-balanced Stimuli. Acta Oto-Laryngologica. https://doi.org/10.1080/00016489950180621
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.