Abstract

Implanted epineural electrodes were used for the longitudinal assessment of peripheral nerve conduction velocity (NCV) and compound action potential (CAP) amplitude in rats. Custom-fabricated stimulating and recording electrodes were sutured over the tibial and sciatic nerves, respectively, and were used for weekly recordings of CAP latency and amplitude. Intra-day variability of nerve conduction velocity measurements had coefficients of variation of less than 2% for same day recordings from individual subjects. A clear trend in recovery of the NCV values following implant was observed over the 7-week trial period. These results demonstrate that implanted epineural electrodes provide a reliable method for chronic, in vivo monitoring of nerve conduction parameters in rodents.

Integrity signals

Registry

Crossref · 10.1016/j.jneumeth.2003.08.013

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • After epineural electrode implantation, fibrous tissue grows around the electrode as part of a foreign body reaction, which stabilizes the electrode, and signals from the nerves become accurate and reproducible.

    “After the implantation procedure, fibrous tissue grows around the electrode as part of a foreign body reaction and this is profitable since it stabilizes the electrode. Following this stabilization process, signals from the nerves are both accurate and reproducible [37, 45].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Murphy, B., Krieger, C., & Hoffer, J.-A.
Affiliations
  • Simon Fraser University (CA)
  • University of British Columbia (CA)
Corresponding author
Krieger, Charles
Venue
Journal of Neuroscience Methods
Publisher
Elsevier BV
Published
2004-01
Volume
132
Issue
1
Pages
25-33
ISSN
0165-0270 (ISSN-L)
OpenAlex
W2016664265
Cited by
13
References
27
Citations by year
2024: 2 · 2023: 2 · 2020: 1 · 2018: 1 · 2017: 1 · 2014: 3
FWCI
0.12
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Neuroscience Methods (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Peripheral Nerve Disorders
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
nerve conduction velocity, compound action potential, peripheral nerves, tibial nerve, sciatic nerve, electrode implantation, longitudinal assessment, rats, measurement variability
MeSH terms
Action Potentials, Animals, Electric Stimulation, Electrodes, Implanted, Electrophysiology, Male, Neural Conduction, Peripheral Nerves, Reaction Time, Time Factors, Rats, Sprague-Dawley, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review