Cited by 70Analog and Mixed-Signal Circuit DesignNeuroscience and Neural EngineeringRadio Frequency Integrated Circuit Design

A 22 V Compliant 56 ${\mu}$ W Twin-Track Active Charge Balancing Enabling 100% Charge Compensation Even in Monophasic and 36% Amplitude Correction in Biphasic Neural Stimulators

Butz, Natalie, Taschwer, Armin, Nessler, Sebastian, Manoli, Yiannos, Kuhl, Matthias·2018·IEEE Journal of Solid-State Circuits

Abstract

Closed-loop charge balancers make a considerable contribution to a safe and secure electrical stimulation and additionally present an alternative to bulky blocking capacitors. This CMOS-integrated, 22 V compliant Twin-Track active charge balancer accomplishes both instantaneous and long-term balanced conditions. Long-term charge balancing is achieved by a cause-based PI-controlled offset compensation of the remaining electrode voltage. A Gm of only 1.5 nS offers a large (8 ms) time constant with only a 12 pF capacitor and leads to the first integrated PI-controller for offset compensation in neural implants. Instantaneous autonomous balancing is realized by a second concept, the consequence-based Inter-Pulse Charge Control. It uses a class-B architecture to supply the compensation currents. Thus, no additional references are required to define the safety window of the remaining electrode voltage. It consumes 31.8 μW in the idle state, while the delivered output power can be as high as 11 mW. The two complementary approaches can be combined to one system, providing the opportunity to achieve a better performance. The system consumes 56 μW and features a 36% mismatch correction in biphasic stimuli amplitude, as well as an autonomous 100% charge removal at maximum compensation amplitudes of 500 μA, which makes it a suitable complement to monophasic stimulators.

Integrity signals

Registry

Crossref · 10.1109/jssc.2018.2828823

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Pulse-width-adaptive charge balancing has been developed as a stand-alone solution or to operate in parallel with offset compensation to overcome high-frequency current spikes blocking neural signals or interfering with next stimulating pulses.

    “To overcome this, pulse-width-adaptive charge balancing has been developed as a stand-alone solution or to operate in parallel with offset compensation [147], [148].”
  • Real-time monitoring is performed by measuring the remaining electrode voltage with respect to the reference to ensure it remains within a pre-defined safety window, e.g., ± 50 mV or ± 100 mV, using a HV fully differential transconductance amplifier.

    “Real-time monitoring is performed by measuring the remaining electrode voltage with respect to the reference to ensure it remains within a pre-defined safety window, e.g., ± 50 mV or ± 100 mV, using a HV fully differential transconductance amplifier [148].”

Cites

Flagged first, then by citations

2 of the 29 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Butz, N., Taschwer, A., Nessler, S., Manoli, Y., & Kuhl, M.
Affiliations
  • University of Freiburg (DE)
  • Hahn-Schickard-Gesellschaft für angewandte Forschung (DE)
  • Hamburg University of Technology (DE)
Venue
IEEE Journal of Solid-State Circuits
Published
2018-08
Volume
53
Issue
8
Pages
2298-2310
ISSN
  • 0018-9200 (ISSN-L)
  • 1558-173X
OpenAlex
W2804781280
Cited by
70
References
29
Citations by year
2026: 5 · 2025: 11 · 2024: 15 · 2023: 15 · 2022: 6 · 2021: 10 · 2020: 2 · 2019: 5 · 2018: 1
FWCI
1.80
Type
journal article
Language
en
Open access
closed
Locations
IEEE Journal of Solid-State Circuits (publishedVersion)
Funders
  • German Research Foundation (DFG) (MA 2193/20-1)
  • BrainLinks-BrainTools Cluster of Excellence (DFG) (EXC 1086)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
neural stimulator, biphasic stimulation, PI controller, class B amplifier, low-power integrated circuits, neural implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›