CoChat

Measurement of work and power output using friction-loaded cycle ergometers

LAKOMY, H. K. A. · 1986 · Ergonomics
Cited by 183

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Friction-loaded cycle ergometers are widely used to measure the work done in short-duration high-intensity exercise. This work is calculated from the product of the average values of flywheel speed and resistive load. This method assumes the flywheel to be revolving at a constant speed and does not take into account the work required to accelerate it. This study examines the possible error resulting from such an assumption. Ten subjects (five males and five females) each performed a single bout of 30 s maximal exercise on a cycle ergometer, from a rolling start, against a resistive loading of 75 g/kg bodyweight. High frequency logging of the flywheel speed was performed by a microcomputer. Two sets of instantaneous and average values of power and work were calculated by the computer at the conclusion of the exercise. The first used the standard method of calculation and did not take into account the acceleration of the flywheel, whereas the second corrected for it. Statistical comparisons of the two sets of results showed: (1) That when no correction is made for flywheel acceleration peak power is greatly underestimated (mean 35·8 ±9·3%). (2) The time taken to reach peak power is shorter when corrected values are used. (3) The instantaneous values of power throughout the 30 s, and the work done calculated for 5 s time intervals, were also different. (4) The total work done during the 30 s was, however, the same irrespective of the method of calculation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00140138608968287

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 183

Metadata

Authors
LAKOMY, H. K. A.
Venue
Ergonomics
Published
1986-04
Volume
29
Issue
4
Pages
509-517
ISSN
  • 0014-0139 (ISSN-L)
  • 1366-5847
OpenAlex
W2006646089
Cited by
183
References
1
FWCI
2.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of work and power output using friction-loaded cycle ergometers. https://app.cochat.ai/papers/10.1080/00140138608968287
The paper
LAKOMY, H. K. A. (1986). Measurement of work and power output using friction-loaded cycle ergometers. Ergonomics. https://doi.org/10.1080/00140138608968287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.