CoChat

Evaluation of commercial, wireless dermal thermometers for surrogate measurements of core temperature

Open access
Zsuzsanna Balla, Hajnal, Theodorsson, Elvar, Ström, Jakob O. · 2019 · Scandinavian Journal of Clinical and Laboratory Investigation
Cited by 14

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Extensive research has been devoted to developing methods for assessing core body temperature, and to determine which method is most accurate. A number of wireless dermal thermometers for home use are presently available, but their relation to core body temperature and suitability for use in clinical research has hitherto not been assessed. The current study aimed to evaluate such thermometers by comparing them to the results of a rectal thermometer. Four wireless dermal thermometers for home use (FeverSmart, iThermonitor, Quest Temp Sitter, and Thermochron iButton) were applied to 15 patients during 24 h, and rectal temperature was measured at four occasions. Pearson correlation revealed moderate correlation for the Feversmart (r = 0.75), iThermonitor (r = 0.79), and Thermochron iButton (r = 0.71) systems. The Quest Temp Sitter system malfunctioned repeatedly, and the correlation (r = 0.29) for this method should therefore be assessed with caution. All dermal thermometers rendered lower average temperatures than Terumo c405 (Feversmart -0.70 ± 0.65 °C; iThermonitor -0.77 ± 0.53 °C, Quest Temp Sitter -1.18 ± 0.66 °C, and Thermochron iButton -0.87 ± 0.65 °C). Sensitivity of the dermal thermometers for detecting core temperatures ≥38.0 °C was low, ranging from 0.33 to 0.6, but improved to 0.60 to 0.80 after adjusting temperatures by the methods' average deviation from rectal temperature. The results from the dermal thermometers tested here showed an insufficient correlation to core temperature to be used for core temperature monitoring in clinical research and practice. Unfortunately, other options for non-invasive temperature measurements are few. The two thermometers with the least unsatisfactory performance profile in our evaluations were the Feversmart and iThermonitor systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/00365513.2018.1519722

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 11

  1. 10.1016/j.ijnurstu.2009.05.002 · DOI
  2. 10.1186/s13049-015-0178-z · DOI
  3. 10.1016/j.ijnurstu.2008.11.006 · DOI
  4. 10.1007/s00134-002-1619-5 · DOI · Paper page
  5. 10.1016/S0736-4679(01)00457-7 · DOI
  6. 10.4085/1062-6050-47.3.09 · DOI · Paper page
  7. 10.1016/j.jtherbio.2014.08.010 · DOI
  8. 10.1016/j.sleep.2010.12.011 · DOI
  9. 10.1016/j.pedn.2011.04.004 · DOI
  10. 10.1016/j.ejon.2009.03.006 · DOI
  11. 10.1016/j.ijnurstu.2010.11.003 · DOI

Cited by

See all 14

Metadata

Authors
Zsuzsanna Balla, H., Theodorsson, E., & Ström, J. O.
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
2019-02-17
Volume
79
Issue
1-2
Pages
1-6
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W2921705185
Cited by
14
References
2
FWCI
2.45
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.