Radioimmunoassay of 8-arginine-vasopressin (antidiuretic hormone) in human plasma
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A radioimmunoassay for 8-arginine-vasopressin (AVP) measurement in human plasma has been developed and evaluated, using a commercial preparation of an antibody of AVP. Detection limit of the assay was 0.4 pg. A simple acetone extraction procedure gave a recovery of 65% of added [125I]AVP. The overall sensitivity in the assay was 1.0 pg/ml when 2 ml plasma samples were extracted. The antigenic sites of the employed antibody seemed to be a combination of amino acid residues in the tripeptide tail and the pentapeptide ring. This can explain that the antibody was almost completely insensitive to chemically or enzymatically degraded AVP. The inter-assay coefficient of variation for the control plasma pools averaged 17%. A good correlation to plasma osmolalities above 290 has been found. AVP level in recumbent subjects (n = 8) with plasma osmolalities in the normal range was 2.8 +/- 1.0 pg/ml (mean +/- SD) and in ambulatory subjects (n = 10) on ad lib. water intake 4.5 +/- 1.9 pg/ml (mean /+- SD).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robertson, G. L., Mahr, E. A., Athar, S., & Sinha, T. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107423 · Cited by 787
Immunoassay of plasma vasopressin in man
Robertson, G. L., Klein, L. A., Roth, J., & Gorden, P. (1970) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.66.4.1298 · Cited by 83
Cited by
Syndrome of inappropriate secretion of antidiuretic hormone (SIADH) in malignant disease
SØRENSEN, J. B., ANDERSEN, M. K., & HANSEN, H. H. (1995) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1995.tb00907.x · Cited by 303
Leckman, J. F. (1994) · Archives of General Psychiatry · doi:10.1001/archpsyc.1994.03950100030003 · Cited by 209
Cerebrospinal-fluid vasopressin in neurological and psychiatric-disorders
Sorensen, P. S., Gjerris, A., & Hammer, M. (1985) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.48.1.50 · Cited by 103
Self-citationRelationship between plasma osmolality and plasma vasopressin in human subjects.
Hammer, M., Ladefoged, J., & Olgaard, K. (1980) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1980.238.4.e313 · Cited by 52
Self-citation
Metadata
- Authors
- Hammer, M.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1978-12
- Volume
- 38
- Issue
- 8
- Pages
- 707-716
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W1970278985
- Cited by
- 40
- References
- 2
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.