Evaluation of the Dade Behring N Latex Cystatin C assay on the Dade Behring Nephelometer II System
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The Dade Behring N Latex Cystatin C assay, a particle-enhanced nephelometric immunoassay for measuring serum cystatin C, was evaluated on the Dade Behring Nephelometer II. The assay time was 6 min and the throughput was 75 samples per hour. The sample volume was 40 microL and the measuring range was 0.25-7.90 mg/L. Imprecision studies revealed within-run CVs < 1.8% and between-run CVs < 1.8% in the concentration range 0.87-4.63 mg/L. Recovery was 92.4-101.3%. Linearity studies showed excellent correlation between the theoretical and obtained values. No interferences were detected from haemoglobin < 1.0 mmol/ L, bilirubin <512 micromol/L and Intralipid <20 g/L. Stability of cystatin C in serum was 7 days at temperatures from 20 degrees C to 20 degrees C and 6 months at -80 degrees C. Measurements of cystatin C in heparin-plasma and EDTA-plasma did not differ significantly from cystatin C measured in serum. Fifty patient samples run on the Dade Behring Nephelometer II (y) were compared to the Dako Cystatin C assay (x). The Passing-Bablok regression analysis revealed y = 1.105x - 0.340. In conclusion, the Dade Behring N Latex Cystatin C assay was precise and correlated with the Dako Cystatin C assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Passing, H., & Bablok, W. (1983) · cclm · doi:10.1515/cclm.1983.21.11.709 · Cited by 1,513
Kyhse-Andersen, J., Schmidt, C., Nordin, G., Andersson, B., Nilsson-Ehle, P., Lindström, V, & Grubb, A. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.10.1921 · Cited by 511
Renal handling of radiolabelled human cystatin C in the rat
Tenstad, O., Roald, A. B., Grubb, A., & Aukland, K. (1996) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519609088795 · Cited by 456
Diagnostic value of analysis of cystatin C and protein HC in biological fluids.
GRUBB, A. O. (1992) · PubMed · Cited by 359
Human gamma-trace, a basic microprotein: amino acid sequence and presence in the adenohypophysis.
Grubb, A., & Löfberg, H. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.9.3024 · Cited by 327
Finney, H., Newman, D. J., Gruber, W., Merle, P., & Price, C. P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.6.1016 · Cited by 318
Barrett, A. J., Fritz, H., Grubb, A., Isemura, S., Järvinen, M., Katunuma, N., Machleidt, W., Müller-Esterl, W., Sasaki, M., & Turk, V (1986) · Biochemical Journal · doi:10.1042/bj2360312 · Cited by 315
GRUBB, A., SIMONSEN, O., STURFELT, G., TRUEDSSON, L., & THYSELL, H. (1985) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1985.tb08880.x · Cited by 303
The place of human γ-trace (cystatin C) amongst the cysteine proteinase inhibitors
Barrett, A. J., Davies, M. E., & Grubb, A. (1984) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(84)91302-0 · Cited by 294
Graphical comparisons of interferences in clinical chemistry instrumentation.
Glick, M. R., Ryder, K. W., & Jackson, S. A. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.3.470 · Cited by 289
Löfberg, H., & Grubb, A. O. (1979) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517909108866 · Cited by 205
Norlund, L., Fex, G. A., Lanke, J., von Schenck, H., Nilsson, J.-E., Leksell, H., & GRUBB, A. O. (1997) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519709084595 · Cited by 163
Collé, A., Tavera, C., Prévot, D., Leung-Tack, J., Thomas, Y., Manuel, Y., Benveniste, J., & Leibowitch, J. (1992) · Journal of Immunoassay · doi:10.1080/15321819208019824 · Cited by 49
The Use of Monoclonal Antibodies to Define Levels of Cystatin C in Normal Human Serum
ISHIGURO, H., Ohkubo, I., Mizokami, M., Titani, K., & Sasaki, M. (1989) · Hybridoma · doi:10.1089/hyb.1989.8.303 · Cited by 45
Cited by
Serum cystatin C is superior to serum creatinine as a marker of kidney function: A meta-analysis
Dharnidharka, V. R., Kwon, C., & Stevens, G. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.34487 · Cited by 1,663
Cystatin C and the Risk of Death and Cardiovascular Events among Elderly Persons
Shlipak, M. G., Sarnak, M. J., Katz, R., Fried, L. F., Seliger, S. L., Newman, A. B., Siscovick, D. S., & Stehman-Breen, C. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043161 · Cited by 1,249
Markers of Inflammation, Coagulation, and Renal Function Are Elevated in Adults with HIV Infection
Neuhaus, J., Jacobs, Jr., Baker, J. V., Calmy, A., Duprez, D., La Rosa, A., Kuller, L. H., Pett, S. L., Ristola, M., Ross, M. J., et al. (2010) · The Journal of Infectious Diseases · doi:10.1086/652749 · Cited by 869
“8% [9–13].”
Factors other than glomerular filtration rate affect serum cystatin C levels
Stevens, L. A., Schmid, C. H., Greene, T., Li, L., Beck, G. J., Joffe, M. M., Froissart, M., Kusek, J. W., Zhang, Y. (., Coresh, J., et al. (2009) · Kidney International · doi:10.1038/ki.2008.638 · Cited by 809
Cystatin C as a marker of GFR—history, indications, and future research
Filler, G., Bökenkamp, A., Hofmann, W., Le Bricon, T., Martínez-Brú, C., & Grubb, A. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.09.025 · Cited by 734
Metadata
- Authors
- Erlandsen, E. J., Randers, E., & Kristensen, J. H.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 59
- Issue
- 1
- Pages
- 1-8
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2144367890
- Cited by
- 258
- References
- 15
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.