Endomysial and Tissue Transglutaminase Antibodies in Coeliac Sera: a Comparison not Influenced by Previous Serological Testing
The DOI matches its Crossref record.
Abstract
BACKGROUND: Since transglutaminase was shown to be the antigen of endomysial antibodies (EMA), it has become possible to screen for coeliac disease (CD) with an enzyme-linked immunosorbent assay (ELISA) for transglutaminase antibodies (TTA). However, it is possible that sera used to show that TTA are found in CD were obtained from patients diagnosed because they were positive for EMA. So, a comparison between EMA and TTA has not been possible so far. METHODS: EMA and TTA were tested in sera from 52 controls and 56 untreated CD patients, who had not undergone serological testing. Samples were tested for TTA with an ELISA kit. Based on the ROC analysis of a pilot study, results were considered as either positive, borderline, or negative. EMA were analysed by indirect immunofluorescence on monkey oesophagus. RESULTS: Forty-nine CD patients were positive for TTA, six borderline, one negative. Forty-four controls were negative, seven borderline, one positive. If we consider borderline results to be positive, sensitivity is 98.2% and specificity 84.6%. EMA were positive in 53 CD patients; the controls were all negative. Performing TTA in all cases and EMA only in the few TTA borderline cases (12.0%) would have a sensitivity of 94.6% and a specificity of 98.1%. CONCLUSIONS: This study is the first to compare TTA with EMA. Due to 100% specificity and high sensitivity, EMA seems to be the most accurate coeliac antibody. Conversely, TTA offer advantages in terms of sensitivity and simplicity. A satisfactory strategy is to use TTA first and then EMA to confirm the borderline results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mustalahti, K., Catassi, C., Reunanen, A., Fabiani, E., Heier, M., McMillan, S., Murray, L., Metzger, M.-H., Gasparin, M., Bravi, E., et al. (2010) · Annals of Medicine · doi:10.3109/07853890.2010.505931 · Cited by 765
The diagnostic accuracy of serologic tests for celiac disease: A systematic review
Rostom, A., Dubé, C., Cranney, A., Saloojee, N., Sy, R., Garritty, C., Sampson, M., Zhang, L., Yazdi, F., Mamaladze, V., et al. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.02.028 · Cited by 512
LEWIS, N. R., & SCOTT, B. B. (2006) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2006.02967.x · Cited by 173
Biagi, F., Bianchi, P. I., Marchese, A., Trotta, L., Vattiato, C., Balduzzi, D., Brusco, G., Andrealli, A., Cisarò, F., Astegiano, M., et al. (2012) · British Journal of Nutrition · doi:10.1017/s0007114511007367 · Cited by 151
Self-citationScreening for associated autoimmune disorders in Polish patients with Addison’s disease
Fichna, M., Fichna, P., Gryczyńska, M., Walkowiak, J., Żurawek, M., & Sowiński, J. (2010) · Endocrine · doi:10.1007/s12020-010-9312-x · Cited by 47
Harder, G., Schiepatti, A., Biagi, F., Borrelli de Andreis, F., Agazzi, S., Gabrielli, G. M., & Klersy, C. (2020) · British Journal of Nutrition · doi:10.1017/s0007114520000537 · Cited by 9
Self-citation
Metadata
- Authors
- Biagi, F., Pezzimenti, D., Campanella, J., Vadacca, G. B., & Corazza, G. R.
- Venue
- Scandinavian Journal of Gastroenterology
- Publisher
- Informa UK Limited
- Published
- 2001-09-01
- Volume
- 36
- Issue
- 9
- Pages
- 955-958
- ISSN
- 0036-5521 (ISSN-L)
- 0000-0000
- OpenAlex
- W2136016849
- Cited by
- 45
- References
- 0
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.