Numerical Investigation of the Air-Side Thermal Hydraulic Performance of a Louvered-Fin and Flat-Tube Heat Exchanger at Low Reynolds Numbers
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
In this study, the air-side heat transfer and fluid flow characteristics of a louvered-fin and flat-tube type heat exchanger used in the household refrigerators were investigated numerically. Louver angles of 20°, 24°, 28°, and 32° and fin pitches of 1.50, 2.00, and 2.50 mm were tested. To represent domestic refrigeration systems, the simulations were conducted for low Reynolds numbers, between 223 and 573. The results were evaluated using the volume goodness factor for the air side. The best performance was obtained with louver angle of 20° and fin pitch of 1.50 mm at Reynolds number of 229 over the investigated cases. It was demonstrated that the Colburn j-factor, friction factor, Stanton number, and volume goodness factor did not change linearly with respect to the parameters considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In particular, the low Reynolds number region which has the significant changes of j/f 1/3 ratio for the smaller flow depths can be illuminated with another study by Erbay et al. [6] as shown in Figure 23.”
From Comprehensive Study of Heat Exchangers with Louvered Fins (2017) · cites this paper as Erbay et al. [6]
In the citing paper
“The j/f 1/3 ratios of the study of Erbay et al. [6] are obtained for a constant flow depth of 20 mm by numerically.”
From Comprehensive Study of Heat Exchangers with Louvered Fins (2017) · cites this paper as Erbay et al. [6]
In the citing paper
“however, there is not linear relationship for the geometric parameters.”
From Comprehensive Study of Heat Exchangers with Louvered Fins (2017) · cites this paper as Erbay et al. [6]
In the citing paper
“It seen that the j/f 1/3 ratio for all the geometries has a similar trend with respect to the Reynolds number; however, there is not linear relationship for the geometric parameters.”
From Comprehensive Study of Heat Exchangers with Louvered Fins (2017) · cites this paper as Erbay et al. [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A generalized heat transfer correlation for Iouver fin geometry
Chang, Y.-J., & Wang, C.-C. (1997) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(96)00116-0 · Cited by 493
Air-side thermal hydraulic performance of multi-louvered fin aluminum heat exchangers
Kim, M.-H., & Bullard, C. W. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00025-1 · Cited by 280 · cited 4×
“the numerical results of Perrotin and Clodic [37] and the experimental results of Kim and Bullard [10].”
BackgroundMethodResultInfluentialAzzouz, K., Leducq, D., & Gobin, D. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.03.012 · Cited by 211 · cited 1×
“In France, refrigerators consume about 26% of the residential electricity demand and they are estimated to be responsible for 17% of the overall greenhouse gas emission in the country [6].”
BackgroundHeat transfer and pressure drop correlations for the multi-louvered fin compact heat exchangers
Dong, J., Chen, J., Chen, Z., Zhang, W., & Zhou, Y. (2007) · Energy Conversion and Management · doi:10.1016/j.enconman.2006.11.023 · Cited by 174
A generalized friction correlation for louver fin geometry
Chang, Y.-J., Hsu, K.-C., Lin, Y.-T., & Wang, C.-C. (2000) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(99)00289-6 · Cited by 161
Novel design and performance enhancement of domestic refrigerators with thermal storage
Marques, A. C., Davies, G. F., Maidment, G. G., Evans, J. A., & Wood, I. D. (2014) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2013.11.043 · Cited by 101 · cited 1×
“It is estimated that refrigeration and air conditioning are responsible for 15% of global electricity consumption [4].”
BackgroundJoardar, A., & Jacobi, A. M. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.10.018 · Cited by 99 · cited 5×
“Park and Jacobi [18] developed an air-side data analysis method for flat-tube heat exchangers under partially wet conditions and demonstrated the method with experimental data for a flat-tube louvered-fin heat exchanger under various latent loads.”
BackgroundInfluentialAir-Side Heat Transfer and Friction Correlations for Flat-Tube Louver-Fin Heat Exchangers
Park, Y.-G., & Jacobi, A. M. (2009) · Journal of Heat Transfer · doi:10.1115/1.3000609 · Cited by 80
Park, Y.-G., & Jacobi, A. M. (2009) · Journal of Heat Transfer · doi:10.1115/1.3089548 · Cited by 70 · cited 5×
“Park and Jacobi [19] studied experimentally the air-side thermal-hydraulic performance of flat-tube aluminum heat exchangers and measured the heat transfer and pressure drop at air face velocities from 0.”
BackgroundInfluentialAn experimental study of the local heat transfer characteristics in automotive louvered fins
Aoki, H., Shinagawa, T., & Suga, K. (1989) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(89)90018-6 · Cited by 51 · cited 1×
“[12] obtained the locally averaged heat transfer coefficient for the individual louvers in the louver array by measuring the electric power input for the film and the temperature difference between the element and air.”
Background
Research works printed but not linked: 24
- 10.1016/j.applthermaleng.2011.07.023 · DOI
- 10.1016/j.applthermaleng.2008.06.007 · DOI
- 10.1016/j.tifs.2008.03.006 · DOI · Paper page
- 10.1016/j.ijrefrig.2013.06.005 · doi:10.1016/j.ijrefrig.2013.06.005
- 10.1016/j.applthermaleng.2014.03.024 · doi:10.1016/j.applthermaleng.2014.03.024
- 10.1016/S0301-4215(03)00169-1 · doi:10.1016/s0301-4215(03)00169-1
- 10.1615/JEnhHeatTransf.v3.i1.20 · DOI · Paper page
- 10.1016/j.ijheatmasstransfer.2010.04.002 · DOI
- 10.1080/01457631003769211 · DOI
- 10.1016/j.ijheatmasstransfer.2006.06.008 · DOI
- 10.1615/JEnhHeatTransf.v6.i5.30 · DOI · Paper page
- 10.1016/S0017-9310(98)00165-3 · DOI
- 10.1016/j.applthermaleng.2005.11.019 · DOI
- 10.1016/S0894-1777(98)10022-5 · DOI
- 10.1016/j.ijthermalsci.2006.04.010 · DOI · Paper page
- 10.1016/S0017-9310(02)00509-4 · DOI
- Akyüz, S., Investigation of Effect of Fin Height and Fin Pitch to Performance on Air Cooled Mini Micro Channel Condensers, M.Sc. thesis, Institute of Science, University of Eskişehir Osmangazi, Eskişehir, Turkey, 2013.
- 10.1615/JEnhHeatTransf.v2.i3.60 · doi:10.1615/jenhheattransf.v2.i3.60
- Min J., 2005, Journal of Enhanced Heat Transfer, 4, 357
- 10.1615/JEnhHeatTransf.2011002708 · doi:10.1615/jenhheattransf.2011002708
- 10.1016/0894-1777(91)90065-Y · DOI · Paper page
- ANSYS Fluent, User's Guide
- 10.1016/j.ijrefrig.2003.11.005 · DOI · Paper page
- 10.2514/1.9123 · DOI · Paper page
Cited by
Heat transfer enhancement in fin-and-tube heat exchangers – A review on different mechanisms
Sadeghianjahromi, A., & Wang, C.-C. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110470 · Cited by 240
Comprehensive Study of Heat Exchangers with Louvered Fins
Erbay, L. B., Doğan, B., & Öztürk, M. M. (2017) · Heat Exchangers - Advanced Features and Applications · doi:10.5772/66472 · Cited by 31
Self-citation
Metadata
- Authors
- Erbay, L. B., Uğurlubilek, N., Altun, Ö., & Doğan, B.
- Venue
- Heat Transfer Engineering
- Publisher
- Informa UK Limited
- Published
- 2016-11-03
- Volume
- 38
- Issue
- 6
- Pages
- 627-640
- ISSN
- 0145-7632
- 1521-0537
- Cited by
- 32
- References
- 10
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Numerical Investigation of the Air-Side Thermal Hydraulic Performance of a Louvered-Fin and Flat-Tube Heat Exchanger at Low Reynolds Numbers. https://app.cochat.ai/papers/10.1080/01457632.2016.1200382
- The paper
- Erbay, L. B., Uğurlubilek, N., Altun, Ö., & Doğan, B. (2017). Numerical Investigation of the Air-Side Thermal Hydraulic Performance of a Louvered-Fin and Flat-Tube Heat Exchanger at Low Reynolds Numbers. Heat Transfer Engineering. https://doi.org/10.1080/01457632.2016.1200382
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.